• Title/Summary/Keyword: Environment Standard

Search Result 5,368, Processing Time 0.036 seconds

Development of an Embedded Motion Controller based on the IEC 61131-3 International Standard Language (IEC 61131-3 국제표준언어 기반 임베디드 모션제어기의 개발)

  • Kim, Won-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3574-3580
    • /
    • 2009
  • An embedded motion controller supporting the PLC programming environment based on the IEC 61131-3 International Standard Language was developed in this paper. In this developed motion controller, the CoDeSys, one of the IEC61131-3 development tools, was embedded in order to support that of PLC as well as the development environment of the PC, and the various function blocks based on PLCopen standard for motion control such as the linear and circular interpolation control were implemented. Moreover, the ethernet based remote control on real-time operating system and the motion simulator for a motion programmer were implemented.

Concentration and Seasonal Variation of Gaseous Nitrous Acid in Seoul Air (서울대기중 아질산기체의 계절별 농도변화)

  • 이용근;김종욱;이동수;백선영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.24-31
    • /
    • 1994
  • Hourly variation of gaseous nitrous acid( HNO$_2$) concentration in Seoul air was monitored from Jan. 11 to SeP. 12, Nitrous acid concentration was determined by DS/IC over nine months of observation, HNO$_2$ range from 0.04 ppb to 5.5 ppb. Gor-tex tube as gaseous HNO$_2$generator in this study is thought to be more convenient and reproducible device than previous generator. As a result of NaOH instead of Na$_2$ CO$_3$/NaHCO$_3$ solution as the IC eluent, we could obtain more stable baseline. The concentration of the NaOH eluent was 15 mM . The limit of detection(3$\sigma$) of the liquid- Phase and gas phase nitrous acid of this method are 1.1ng/$m\ell$ , 0.04 n $\ell$ / $\ell$, respectively. The precisions evaluated by 10 replicate analysis of standard solution and standard gas generated are $\pm$1.59, $\pm$2. 89% RSD, respectively. Due to the lack of standard material for air, direct assessment of the accuracy was not possible. This study was applied to the analysis of Seoul ambient air and their results are reported herein.

  • PDF

형광 X선에 의한 대기 부유분진중의 미량 성분의 측정 (I): -거름종이 표준시료에 의한 부유분진중 금속성분의 형광 X선 분석-

  • 이용근;맹현재;이보경;황규자
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.21-29
    • /
    • 1989
  • The metals present in atmospheric particulate come from various sources; natural or anthropogenic. Among various metals Fe, Zn, Pb, Cu, and Mn are of particular concern in as much as they are not only present in large quantity, but toxic to human body. A simple, fast, and non-destructive analytical method for these metals in atmospheric particulate was developed and the analytical details were described herein. The method involves the measurements of X-ray fluorescence of sample contained in filters and comparing it with those for standards. The standard filters were prepared by applicating premeasured standard solution to the filters and then drying. The accuracy of the method was tested by analyzing standard reference materials and by independently analyzing samples using a different, previously accuracy-proven method, inductively coupled plasma atomic emission spectrometry, and comparing the results obtained. Analytical sensitivities and detection limits of the present method were 62.9, 178.2, 82.9, 146.1, 37.2, 120.3 cps/$\mug/cm^2$ and 39.0 35.6, 137.5, 125.9, 182.6, 72.8 $ng/cm^2$ for Fe, Zn, Pb, Cu, Mn, and Ni respectively. The method was applied to Seoul atmospheric particulate and some results were reported.

  • PDF

The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data - (농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Yun, Young Il;Song, Jeong Suk;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

A Study on Standard Repair Periods, Repair Rates of School Facilities for Revitalizing of the School BTL Project (학교 BTL사업의 활성화를 위한 학교시설의 수선주기와 수선율 및 내용연수 산정에 관한 연구 -서울시내 초·중·고등학교를 중심으로-)

  • Ha, Ho-Sung
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.1
    • /
    • pp.60-84
    • /
    • 2007
  • This study purpose is seeing that the independent standard sufficiently reflecting the characteristics of the school facility as the basic material needed to calculate the maintenance and repair expenses is needed to make a more realistic and valid qualitative VFM analysis of the school BTL project. this study attempted to develop the standard for the repair cycle and rate and economic year of the school facility. The quantitative VFM analysis should be conducted based on the repair cycle and repair rate proper to the school facility, not the residential space, when calculating the maintenance and repair expenses of the operating expenses of the school facility. An attempt was made to calculate the repair cycle, repair rate and economic life of 114 component materials of the school facility judged to be able to explain the school field best. And it was confirmed that the repair and maintenance expenses more is needed to be set by about 35% than the existing maintenance and repair expenses.

  • PDF

Effect of Environmental Enrichment on Cognitive Impairment-induced by Ethanol Exposure in Adolescent Rat

  • Kim, Yoon Ju;Park, Jong Min;Song, Min Kyung;Seong, Ho Hyun;Kim, Youn Jung
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.4
    • /
    • pp.274-279
    • /
    • 2016
  • Purpose: Adolescents who experienced the alcohol consumption have gradually increased. Adolescence is a critical period of the neural plasticity in the brain. Neural plasticity is mediated by neurotrophins and has an impact on cognitive function. Environmental enrichment ameliorates the cognitive function and increases neurotrophins. Thus, we investigated the neuroprotective effect of environmental enrichment on ethanol induced cognitive impairment in adolescent rats. Methods: The ethanol groups and the controls groups were injected with ethanol (0.5g/kg) and phosphate buffered saline, respectively, through intraperitoneal from 28th day of birth for 11 days. The environmental enrichment groups were provided larger cages containing toys than the standard cage. Passive avoidance test and Y-maze test were performed to evaluate the spatial memory. Results: Environmental enrichment+ethanol group showed higher alterations than the standard environment+ethanol group in Y-maze test (p<.05). In hippocampus, The environmental enrichment+ethanol group showed significantly higher level of the number of c-fos positive celsl and density of tropomyosin receptors kinase B receptor than the standard environment+ethanol group (p<.05). Conclusion: So, we suggested that the environmental enrichment played a role as a prophylaxis for prevention of memory impairment induced by ethanol exposure in adolescence.

Validation of Suitability on Proficiency Testing Samples for Acute Toxicity Test with Daphnia magna (생태독성 숙련도 시료의 적절성 평가)

  • Shin, Kisik;Park, Woosang;Lee, Jungseo;Yu, Soonju;Park, Taejin;Kim, Jongmin
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Acute toxicity test with Daphnia magna has a variety of factors such as incubation condition of test species, food quality and proficiency of laboratory workers. Therefore, proper proficiency testing samples were required for evaluating the competence of laboratory workers. This study aims to propose some appropriate proficiency testing samples for laboratory workers of acute toxicity test with Daphnia magna. Proposed four kinds of standard samples (Sample A, B, C, and D) for proficiency testing were selected from reference materials which were recommended from Canada and USA WET(Whole Effluent Toxicity) authorities. Proposed standard samples were tested by trial application of proficiency testing, homogeneity and stability checks using repeatability test. Sample A, C and D were estimated ad the suitable candidates for proficiency test standard samples except for Sample B. In addition, Sample A was proved to be the most suitable sample.

Application of activated carbon bugs to the dye tracer study in a Karst area

  • Hwang Hyeon-Tae;Lee Myeong-Jae;Choi Ye-Gwon;Mok Jong-Gu;Lee Jin-Yong;Kim Yong-Cheol;Yeom Byeong-U
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.407-410
    • /
    • 2006
  • Studies were performed on evaluating the applicability of activated carbon bugs on dye tracer tests as tracer detectors by using its adsorption isotherm of the grained activated carbon. We preliminary conducted several standard adsorption and extraction tests and obtained the relationship between standard dye solution and detected concentrations from activated carbon samples in dry and wet conditions. the slopes of the regression line were 0.71 for wet condition and 0.74 for dried one. Field dye tracer tests were performed in a karst area, where several faults occur along a stream and pass the test area. We sampled water samples and activated carbon samples at three points in Hwangji Pond, where groundwater outflows from the karst conduit. According to the results of breakthrough curve analysis, the regional flow along the conduit, which is assumed to cause a karst conduit, was estimated as 0.18 m/day. The relationship between the concentrations of water sample and extracted activated carbon bugs shows the similar slopes with those from standard solution tests. This suggests that activated carbon could be useful as a dye tracer detector because the extraced concentration can be quantified.

  • PDF

The Effect of Wind Force on Stability of Agricultural Structures - Numerical Calculation of Wind Pressure Coefficients - (풍하중이 농업시설물의 구조적 안정성에 미치는 영향 -수치해석에 의한 풍력계수분포 산정-)

  • 최홍림;손정익
    • Journal of Bio-Environment Control
    • /
    • v.3 no.1
    • /
    • pp.10-19
    • /
    • 1994
  • Wind load is known to be one of major forces to influence the stability of agricultural structures. General flow fields were calculated to determine flow characteristics over the envelop of the following three types of greenhouses with arched roof : single span, twin span greenhouses, and two single span greenhouses apart 3m inbetween. Pressure coefficients along the envelop of greenhouse were numerically calculated by the k-$\varepsilon$ turbulence model, which lead to determine wind forces on it. Curvilinear coordinate for an arched roof and the upwind scheme were adopted for the study. The calculated pressure coefficients were validated with the avaliable data of Japanese Standard and NGAM Standard. The Magnitude of calculated forces over the envelop was not in good accordance with data except the windward wall. Even tile data of Japanese and NGAM Standard for validation deviated a lot from each other in quantity and quality. Such discrepancy may be attributed to different geometric and/or flow configuration conditions for experiments, or the insenstivity of the k-$\varepsilon$ turbulence model to recirculation flow.

  • PDF

Some Comments on Revision of Memorandum of Understanding on Port State Control in Asia-Pacific Region and Actualities of Korean PSC Regime (아태지역항만국통제에 관한 양해각서의 개정과 비판)

  • 강동수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.7 no.3
    • /
    • pp.93-106
    • /
    • 2001
  • Whether a ship is sub-standard or not shall be finally decided by the minimum standards laid down in international conventions or national standards having the same effects. The flag State is primarily responsible for implementing these standards as far as its own ships are concerned. And the port State shall, in the exercise of its rights under international law, take appropriate measures (including detention of ships identified as sub-standard), which are regarded as port State's supplementary role aiming at implementing these standards. The international standards are implemented by the regional co-operation in the form of the MOU(Memorandum of Understanding) on Port State Control in the Asia-Pacific Region on the ground that the PSC enforcement of only one country does not enable the eradication of sub-standard ships. Recently, EQUASIS which is an international database covering the whole world fleet change the regionalism of PSC into the globalization of PSC. However, there are many problems in Tokyo MOV and Korean PSC regime. In order to ensure the implementation of the standards laid down in international conventions and Tokyo MOU, the Korean and other country in Asia-Pacific shall settle the alienation from the actuality of the law, namely the problem of maritime administrative structure of non unifying PSC affairs.

  • PDF