• Title/Summary/Keyword: Environment Standard

Search Result 5,368, Processing Time 0.042 seconds

Comparison of ACFAS method and DNPH-LC method for quantitative analysis of formaldehyde in Drinking water (자동연속흐름-흡광광도법과 DNPH-LC법에 의한 먹는물 중 포름알데히드 정량분석 비교)

  • Yi, Geon-Ho;Yun, In-Chul;Kim, Yeong-Kwan;Kim, Chong-Chaul;Choi, Geum-Jong;Lee, Teak-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.827-836
    • /
    • 2013
  • Due to the stringent drinking water quality, formaldehyde will be included in Korean drinking water standard from year 2014. However, its standard analytical method has not yet been established. This study compares two analytical methods, DNPH-LC and ACFAS with respect to their analysis principles, Method Detection Limit (MDL), Limit Of Quantitation(LOQ), precision, accuracy, reproducibility, convenience, number of samples analyzed per hour and analysis cost. These methods measure absorption intensity at 360 nm by using HPLC after DNPH-derivatization (DNPH-LC) and at 410 nm by using Automated Continuous Flow Absorption Spectrophotometer (ACFAS), respectively. Reproducibility was tested by repeating the analysis 7 times using a standard solution for each method. For DNPH-LC method, MDL was $0.5{\mu}g/L$, LOQ was $1.58{\mu}g/L$ with standard deviation of $0.16{\mu}g/L$. For ACFAS method, they were $0.27{\mu}g/L$, $0.85{\mu}g/L$L with standard deviation of $0.09{\mu}g/L$, respectively. Both methods satisfied the requirement set by the Korean drinking water quality standard. Complexity of sample pretreatment procedure for DNPH-LC method may cause large error and, consequently, the analytical result will depend on the level of skill of analyst. In contrast, ACFAS method which used only one reagent equipped with an automated injection device showed little analytical error. It costs about $5.00 and $1.00 for one sample to analyze by the DNPH-LC method and the ACFAS method, respectively. Compared to the DNPH-LC method, ACFAS method provided more reliable analytical results. In terms of convenience, easiness and analytical cost, ACFAS method was demonstrated to be superior to the DNPH-LC method. The results of this study suggested that the ACFAS method could be adapted as a proper method for determining formaldehyde content in drinking water.

A Study on the Standard Ship's Length of Domestic Trade Port (국내 무역항의 표준 선박길이에 관한 연구)

  • Lee, Yun-Sok;Ahn, Young-Joong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.164-170
    • /
    • 2013
  • With the introduction of increasingly large-sized ships, the conditions of main domestic port facilities remain the same as in the past. So, there is high probability that marine traffic congestion can occur at the certain ship's routes. The standard ship's length used to assess the marine traffic congestion of domestic trade port is 70 meters. It has been in use for the last 30 years, so, its usefulness is highly recommended for review. This study deeply analyzes the tendency of ship's dimensional changes according to recent enlargement of ship's size by utilizing the particulars of 60,000 ships saved in domestic Port-MIS database and suggests the standard ship's length by figuring out the correlation between length of ship and gross tonnage. In addition, the basis of statistical data on the ship's tonnage in domestic trade over the last five years suggests the standard ship's length by deriving the reference point of cumulative incidences that occupy more than over 50 %, except for small vessels. It is necessary to consider the characteristic of each domestic trade port before the actual application of suggested standard ship's length.

Comparative Analysis of Accumulated Temperature for Seasonal Heating Load Calculation in Greenhouses (온실의 기간난방부하 산정을 위한 난방적산온도 비교분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho;Seo, Dong-Uk
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.192-198
    • /
    • 2014
  • To establish the design criteria for seasonal heating load calculation in greenhouses, standard weather data are required. However, they are being provided only at seven regions in Korea. So, instead of using standard weather data, in order to find the method to build design weather data for seasonal heating load calculation, heating degree-hour and heating degree-day were analyzed and compared by methods of fundamental equation, Mihara's equation and modified Mihara's equation using normal and thirty years from 1981 to 2010 hourly weather data provided by KMA and standard weather data provided by KSES. Average heating degree-hours calculated by fundamental equation using thirty years hourly weather data showed a good agreement with them using standard weather data. The 24 times of heating degree-day showed relatively big differences with heating degree-hour at the low setting temperature. Therefore, the heating degree-hour was considered more appropriate method to estimate the seasonal heating load. And to conclude, in regions which are not available standard weather data, we suggest that design weather data should be analyzed using thirty years hourly weather data. Average of heating degree-hours derived from every year hourly weather data during the whole period can be established as environmental design standards, and also minimum and maximum of them can be used as reference data for energy estimation.

A Study on Strengthening Option of T-N Effluent Water Quality Standards of Sewage Treatment Plants (하수처리시설의 T-N 방류수 수질기준 강화방안에 관한 연구)

  • Kim, Ji Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.216-225
    • /
    • 2018
  • Over the past 40 years, the public sector has continued to invest in the sewage treatment plants (STPs) in Korea. Currently, the domestic sewage treatment rate is over 90% with the enhancement of operating efficiency of the STPs, and water quality of major rivers has been continuously improved. However, COD and T-N indicators are stagnating or slightly worsening, and though advanced treatment facilities are installed in most of the STPs, there is a limit to the removal of nutrients. Since there are a lot of water pollution sources in the vicinity of the watershed because of high population density in Korea, it is essential to reduce the inflow of the nutrients in order to prevent the eutrophication of the rivers and lakes. While the effluent T-P standard in STPs has greatly strengthened since 2012, which results in the considerable investment for the improvement of treatment process in STPs for the last few years, it is necessary to strengthen the T-N standards, as the effluent standard of T-N has been maintained at 20 mg/L since 2002. In this study, based on the analysis of the effluent T-N standard status of major industrialized countries, and the domestic nitrogen load in public waters, the option of appropriate T-N standard level is reviewed, and the required investment costs and the effect of strengthening the standard are estimated.

Nurses' Knowledge, Attitude, and Compliance with Hospital Infection Standard Precautions (간호사의 감염예방 표준주의지침 지식, 태도 및 준수 정도)

  • Lee, Kyoung Hee;Choi, Joo Ok;Lee, Kyeong-Soo;Hur, Jian;Hwang, Tae-Yoon
    • Korea Journal of Hospital Management
    • /
    • v.19 no.2
    • /
    • pp.34-43
    • /
    • 2014
  • This study was conducted to investigate the degree of nurses' knowledge, attitudes, and compliance with hospital infection standard precautions. The study subjects were nurses in a university hospital in Daegu, South Korea, and a self-administered survey was carried out using a standardized questionnaire from 1st to 15th August, 2012. A total of 187 questionnaires were used for analysis. Those who were injured by a syringe needle for the last year accounted for 29.96%, and those exposed to patients' blood or body fluid on their damaged skin/mucous membranes accounted for 26.2%. There were statistically significant differences in attitude and compliance according to safety environment for hospital infection standard precautions. The knowledge score of the subjects about standard precautions was $15.30{\pm}1.51$ on a 19 point scale and had significant difference according to the subjects' education level. The attitude score was $2.86{\pm}0.49$ on a 4 point scale and had significant difference depending on how experienced they were on the career. The compliance score was $3.41{\pm}0.38$ on a 4 point scale and had significant difference depending on their age and their experience on the career. In conclusion, it can be said that systematic and continuous practical training is required to improve compliance with standard precautions. Particularly, it is needed to provide less experienced nurses with educational opportunities along with their supervisors' ongoing attention and position personnel appropriately.

  • PDF

The controversial points for the assessment of soil contamination related to the change of pH of extraction solution in using partial extraction in standard method in Korea (국내 토양오염 공정시험방법의 용출법 사용시 용출액의 pH의 변화가 토양 오염 평가에 미치는 문제점)

  • 오창환;유연희;이평구;이영엽
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.294-297
    • /
    • 2000
  • Heavy metals are extracted from Chonju stream sediment, roadside soils and sediments along Honam expressway, soils and tailings from mining area using partial ectraction in Standard Method, partial ectraction method with maintaining 0.1N of extraction solution and acid digestion. In samples having buffer capacity against acid, 0.1N of extraction solution can not be maintained and pH of extraction solution increases up to 8.0 when partial extraction in Standard Method is used. The averages and ranges of (heavy metals extracted using partial extraction in standard method, HPE)/(heavy metals extracted using partial extraction method with maintaining 0.1N of extraction solution, HPEM) values are 0.506 and 0.145~1.126 in Cd, 0.534~ and 0.078~0.928 in Zn, 0.461 and 0.041~1.715 in Mn, 0.359 and 0.011~0.874 in Cu, 0.195 and 0.018~1.785 in Cr, 0.710 and 0.003~3.075 in Pb, and 0.088 and 1.73$\times$10$^{-5}$ ~0.303 in Fe. These data indicate that the difference between HPE and HPEM is big in the order of Fe, Cr, Cu, Mn, Cd, Zn and Pb. It is quite possible that the partial extraction method in Standard Method of soil in Korea is not adequate for an assessment of contamination in area where buffer capacity of soil will be decreased or lost after a long term exposure of soils to environmental damage.

  • PDF

An Institutional Improving Standards for Water Reclamation/Reuse(WRR) System Establishment to Buildings (건축물의 중수도 설치기준에 대한 제도적 개선방안)

  • Kong, Young Hyo
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.43-48
    • /
    • 2006
  • This paper aims to suggest ways of institutionally improving standards that must be applied when installing Water Reclamation/Reuse (WRR) system based on efficiency analysis. Currently, the standard for WRR system establishment requires that the system should treat more than 10% of used water in the building of over $60,000m^2$ in total area of all floors, but our research has found that it would be more effective to change the standard to $150-m^3-per-day$ reclaimed water or the total area of all floors of $30,000m^2$ ($50,000m^2$ in the case of an office building). In other words, what this paper suggests is not a one-size-fits-all standard based on the total area of all floors, but a reasonable and flexible standard that takes into account efficiency and a unit water usage according to a building's purpose. Furthermore, this paper recommends a new WRR standard that can be applied to large-scale land development for housinglots, like the New Town. The recommendation is based on the economic analysis that the WRR system will ensure efficiency only if the amount of reclaimed water is over 4,000 tons per day, which corresponds to 4 millions square meters of housinglots. Regarding the size of the established facility, this paper suggests changing the standard, which is now set at over 10% of water usage, to what is relative to the total amount of use of reclaimed water in order to ensure efficiency and promote use of reclaimed water. In addition, this paper proposes that governmental support should be offered not only to facility owners, who are recipients at present, but also to facility builders. By doing so, those who donate a facility to the government, central or local, after building it, can be provided with substantial aid. Therefore, the application of the institutional improvement suggested in this paper is expected to create environment-friendly living conditions and boost the quality of life by encouraging people to secure water resources efficiently in buildings, and in a wider range, in cities.

The Design and Implementation of EDI Editor using XML (XML을 이용한 전자카달로그 편집기 설계 및 구현)

  • 백현기
    • The Journal of the Korea Contents Association
    • /
    • v.2 no.2
    • /
    • pp.42-46
    • /
    • 2002
  • Transfer of much informations or document necessitated between corporation or corporation and customer by fast growth of electronic commerce. So, it is acting by important success urea that make and manage standard of information in electronic commerce. It was work that work that make standard of information electron catalogue system or EDI environment is very difficult before XML comes out and expense costs much. But, it became easy that make standard of information by XML's entrance on the stage that have advantages of SGML and HTML Specially, it is very suitable that electronic commerce inflects XML as field that heterogeneous system exists and standardization is required urgently. That is, XML is big advantage in side that make out side that is and normalized document because store information in standard form that is applied well under heterogeneous system environment because do web environment by basis interface and can be used efficiently to transmit. Treatise that see hereupon could assume beforehand in browser control using XSLT. And using dynamic DLL XML catalogue edit system design and implementation.

  • PDF

Concentration of Heavy Metals in Seawater, Fish, and Shellfish at Lake Shihwa (시화호 내 수질 및 어패류의 중금속 분포 연구)

  • Lee, Gyuyoung;Lee, Seunghun;Oh, Sehun;Choi, Minji;Lee, Yong-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.157-163
    • /
    • 2018
  • This study aims to determine the pollution levels of nine kinds of heavy metals (As, Cd, Cu, Cr, Hg, Mn, Ni, Pb, and Zn) in Lake Shihwa, which is susceptible to the inflow of pollutants, and the levels of heavy metal exposure in its fish and shellfish. Shihwa Lake's water quality did not exceed the short-term standard for protection of marine ecosystems, but concentrations of As, Cu, Cr, Hg, Ni, and Zn exceeded the long-term standard for protection of a marine ecosystem. In comparison to findings in prior research, performed in 2010, levels of Cr, Ni, As, and Zn are now 4.1 times lower. However, when compared to Saemangeum Lake, the environment is similar to that of Lake Shihwa, Cu, Ni, Hg, Mn, and Zn were 244.4 times higher. The levels of Pb, Cd, and Hg in fish's muscles did not exceed the average values set by the marine safety standard. However, when compared to the fish from the Korean coast, the levels of heavy metals were 9.7 times higher, on average. The levels of heavy metals in fish's livers were on average 26.8 times higher than in the muscles. In the case of shellfish, the levels of Pb, Cd, and Hg did not exceed the standard values, but in comparison to the shellfish from the south coast, the levels of heavy metals were 6.2 times higher on average. In particular, Mn (153.5 times higher) from fish and Cd (14.7 times higher) from shellfish were found in high amounts, indicating a concerning level of these specific heavy metals.