• 제목/요약/키워드: Environment Standard

검색결과 5,368건 처리시간 0.036초

교사환경기준에 관한 연구 (A Study on Environmental Standards of School Building)

  • 홍석표;박영수
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제1권1호
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

부분계측 및 미계측 유역에서 기준유량 산정 방법 비교 연구 (Comparative Study on Evaluating Standard Flow in Partially Gauged and Ungauged Watershed)

  • 김경훈;김정민;정현기;임태효;김성민;김용석;서미진
    • 한국물환경학회지
    • /
    • 제35권6호
    • /
    • pp.481-496
    • /
    • 2019
  • The Ministry of Environment has measured streamflow at eight-day intervals for the estimation of standard flow of the Total Maximum Daily Loads (TMDL) system. This study identified the availability of the partially measured the eight-day interval data for estimating standard flow and found the optimal extension techniques of standard flow. The study area was selected for the Nakbon-A watershed in the Nakdong River, and four streamflow record extension techniques of standard flow were considered: extension, percentile, drainagearea, and regional regression methods. The flow duration curve (FDC) using the eight-day interval streamflow data indicated very high Nash and Sutcliffe Efficiency (NSE) values above 90 % from FDC-II to FDC-VII compared to FDC-VIII, the standard FDC. This result demonstrates that FDC using daily data of three-six cumulative years could represent standard FDC fairly well. For the streamflow record extension techniques of standard flow, the percentile method was selected as the optimal alternative, showing the minimal difference from FDC-VIII. These results validate the availability of the eight-day interval streamflow data in the standard flow estimation and the application of extension techniques. It seems that these results could reduce the uncertainty of partially measured streamflow data for water quantity and quality management.

돌봄제공자의 감염관리를 위한 표준주의 이행도 영향요인 (Factors influencing Healthcare-associated Infection Control of Caregivers)

  • 김지영;장은희
    • 중환자간호학회지
    • /
    • 제14권1호
    • /
    • pp.63-75
    • /
    • 2021
  • Purpose : The purposes of this study were to examine the relationships between knowledge, awareness, safe environment, and performance of standard precautions and identify factors associated with performance of standard precautions. Methods : This study was a descriptive research. A structured questionnaire on knowledge, awareness, safe environment, and performance of standard precautions was used for the survey with a convenience sample of 150 caregivers. Data were collected from July to August 2019 and were analyzed using descriptive statistics, independent t-test, one way ANOVA, Pearson's correlation coefficient, and multiple regression with SPSS/WIN 25.0 program. Results : The mean scores on knowledge, awareness, safe environment, and performance of standard precautions were 15.77±3.34, 7.35±1.91, 4.55±2.05, and 55.20±10.11 respectively. Performance of standard precautions showed a statistically significant positive correlation with knowledge (r=.54, p<.001), awareness (r=.54, p<.001), and safe environment (r=.50, p<.001). Awareness (β=.24, p=.025) and safe environment (β=.35, p<.001) were significantly associated with factors of performance of standard precautions. Also, education level (high school and above college), affiliated institution (private association), and importance of infection control education (moderate) were significantly associated with factors of performance of standard precautions. Conclusion : The results of the study indicate that factors influencing the performance of standard precautions of caregivers were awareness and safe environment. Therefore, to improve implementation of the standard precautions among caregivers, a safe environment within the hospital must be supported, and appropriate infection management education needs to be provided to caregivers to improve their knowledge and awareness of the standard precautions.

자연환경복원산업 활성화를 위한 표준품셈 연구 (A Study on the Standard of Estimate for Vitalizing the Natural Environment Restoration Industry)

  • 진기정;구본학
    • 한국환경복원기술학회지
    • /
    • 제16권2호
    • /
    • pp.23-40
    • /
    • 2013
  • The natural environment restoration industry has been newly included in the environment area of engineering technology. Accordingly, the enactment of a standard of estimate for determining the 'Cost plus Fixed Fee' method has become necessary for the implementation and vitalization of natural environment restoration projects. The purpose of this study is to determine the standards for which the prices for engineering projects are calculated with respect to the enactment of an engineering project standard of estimate in the natural environment restoration field. These include the scope of the technological work, standard area, manpower requirements by technical grade that are necessary for carrying out the technological tasks. Relevant laws and regulations, systems and precedent case studies were investigated and analyzed to establish a price calculation standard. The overall results of the analysis were used and applied to questionnaires, public hearings, and expert delphi techniques. The study showed the following results: The scope of the technological work was categorized into 'Biotopes', 'Eco-corridors' and 'Ecological restoration'. The standard area was set up as $1,000m^2$ for 'Biotopes' and $5,000m^2$ for 'Eco-corridors' and 'Ecological restoration'. The manpower requirements by technical grade that are necessary for carrying out the technological tasks were determined. The suitability of the costs, standard area, manpower requirements by technical grade of ordered engineering projects that are determined by applying the standard of estimate for natural environment restoration that may be enacted pursuant to this study may be effectively investigated and analyzed. Moreover, further studies on the calculation of standard prices that can ensure the stability of natural environment restoration projects will be necessary.

공공의료기관 간호사의 감염 표준주의지침 수행도 영향요인 : 지식, 안전환경 중심으로 (Factors Affecting Nurses' Performance of Standard Precautions for Infection in Public Medical Institutions: Focusing on Knowledge and Safety Environment)

  • 이지인;김종경
    • 한국콘텐츠학회논문지
    • /
    • 제21권7호
    • /
    • pp.238-247
    • /
    • 2021
  • 본 연구는 공공의료기관에 근무하는 간호사의 감염 표준주의지침에 대한 지식, 안전환경, 수행도를 조사하고 표준주의지침에 대한 수행도에 미치는 영향 요인을 확인하기 위한 서술적 조사연구이다. 연구방법은 S시, N시의 2개의 공공의료기관 간호사 192명을 대상으로 설문지를 통해 자료를 수집하였고 SPSS WIN 22.0 통계프로그램을 사용하여 결과를 분석하였다. 연구결과 표준주의지침 지식은 근무경력에 따라 유의한 차이가 있었으며 표준주의지침 안전환경은 직위에 따라 유의한 차이가 있었다. 표준주의지침 지식 정도는 평균 21.98(25점 만점), 안전환경은 평균 5.68(7점 만점), 수행도는 평균 40.28(60점 만점)이었으며, 표준주의지침 안전환경과 표준주의지침 수행도(r=.21, p<0.01)는 유의한 양의 상관관계가 있었다. 표준주의지침 수행도에 미치는 영향요인은 표준주의지침 안전환경(𝛽=.22, p=.003)으로 나타났다. 따라서 공공의료기관에서 간호사의 감염관리를 위한 표준주의지침 수행도를 증진 시키기 위해서는 재정적 지원 및 지지적 안전환경을 제공하고 현 상황을 고려한 차별화된 감염관리 교육프로그램과 모니터링이 요구된다.

폭염발생 기준 설정에 관한 연구 (A Study on Development of the Extreme Heat Standard in Korea)

  • 박종길;정우식;김은별
    • 한국환경과학회지
    • /
    • 제17권6호
    • /
    • pp.657-669
    • /
    • 2008
  • Lately extreme weather event is occurring because of the global warming. Especially disaster due to the extreme heat are increasing but the definition and the standard of the extreme heat is obscure until now. So this study established the extreme heat standard by using the number of daily deaths. As a result, considering the climate of the megalopolis using daily maximum heat index and daily maximum temperature was the best for the standard of the extreme heat. And it showed that extreme heat lasted for 2 days affects the death toll the most. The regional incidence of the extreme heat is highest at August and July, September and June is following.

서울지역 학교 교실의 실내환경 조사연구 (A Study on the Indoor Environment of school classrooms in Seoul area)

  • 최한영
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.67-74
    • /
    • 2003
  • In 15 schools where were chosen each location (East, West, South, North, Central) of Seoul area, 9 items were measured such as thermo circumstance(temperature, relative humidity, air current, intensity of illumination) particulate matter, carbon monoxide, sulfur dioxide, and nitrogen dioxide being based on the school indoor environment standard. It was showed that indoor temperature, relative humidity and air movement were suitable in comparison with school indoor environment standard. Intensity of illumination was suitable in comparison with all schools, only exception 2 schools. In all investigated schools were adequate for carbon monoxide, sulfur dioxide and nitrogen dioxide, in which each indoor environment standard (10ppw, 0.25ppm/hr, 0.15ppm/hr), but in 5 schools the carbon dioxide were exceeded for standard limit 1,000ppm of Korea. Indoor concentration of dust(PM-10) induced from respiration dust the standard of Korea ($150{\mu}g/m^3$) at all schools.

온열환경기준에 따른 여름철 사무실의 열쾌적성 평가 (A Field Survey of Thermal Comfort in Office Building with Thermal Environment Standard)

  • 공효주;윤근영;김정태
    • KIEAE Journal
    • /
    • 제11권3호
    • /
    • pp.37-42
    • /
    • 2011
  • This study aims to analyze the field survey of thermal comfort in office building with national thermal environment standard. Internal and external temperatures were measured at ten minute intervals and compared in accordance with the national standard for thermal environment. Sixty two workers filled in the questionnaire survey forms five times a day for 40 days. Field monitoring of offices in Seoul, Korea were conducted from 20 July to 28 August. Result for the comfort temperature was set a $26.30^{\circ}C$. This indicates that the 26 degree is reliable for the Korean standard. Indoor temperature standard can reduce energy use by air-conditioned buildings and the temperature would be offer comfort to occupants.

환경과 녹색성장 프로젝트 활동에 따른 교사용 평가 기준 개발과 적용 (Development and Application of Teacher's Evaluation Standard for Environment and Green Growth Project Activity)

  • 이성희;최선영;강호감
    • 한국환경교육학회지:환경교육
    • /
    • 제24권4호
    • /
    • pp.32-40
    • /
    • 2011
  • The purpose of this study was to develop an evaluation standard by which teachers in charge of environment and green growth education could conduct a project activity and examine its applicability. The results were as follows; First, 26 evaluation items were developed through interviews with teachers and expert meetings. These categories were base on 'Theme', 'Planning', 'Result' and 'Presentation', and 'Evaluation' of the project. Second, a reliability test showed that internal consistency of the items was currently high(Cronbach's alpha .8709). To examine the content validity, the project activity was evaluated by 5 different teachers, and the result showed that the evaluation standard developed in this study was a very effective tool for the teachers to do project learning. Third, from the 2011 revised national curriculum, the subject 'Environment' in middle schools would be renamed as 'Environment and Green Growth'. Also, environment project activity would be introduced in the middle school. Therefore, this study had a significant importance in the fact that it provided teachers and students with a practical evaluation standard for the environment and green growth project activity.

  • PDF

하천 유량.수질변화 특성을 고려한 수질오염총량관리 기준유량 조건에 관한 연구 (A Study on the Suggestions for Standard Flow Conditions considering the Variation of Stream Flow and Water Quality for the Management of Total Maximum Daily Loads)

  • 박준대;오승영;최윤호
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.426-435
    • /
    • 2012
  • The variation of stream flow is the one of the most important factors which influence on that of water quality in the unit watershed. The target water quality goal is established and permissible load is allotted in the base of the standard flow condition along with its water quality for the management of Total Maximum Daily Loads (TMDLs). A standard flow selected could cause problems in the load allotment if it was not properly arranged. This study reviewed the acquisition of water quality data, the self-variation and the retainability in water quality on the specific flow conditions. This study also proposed the median and the adjusted average flow condition out of general flow conditions as alternative standard flow conditions. It is considered that the alternatives can make the water quality data easily acquired and the water quality representativeness more enhanced on the standard flow conditions.