• Title/Summary/Keyword: Envelope System

Search Result 407, Processing Time 0.026 seconds

Design of High-efficiency Power Amplifier System for High-directional Speaker (고지향성 스피커를 위한 새로운 전력 증폭기 설계)

  • Kim, Jin-Young;Kim, In-Dong;Moon, Wonkyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1215-1221
    • /
    • 2017
  • Parametric array transducers are used for highly directional speaker in an air environments. Piezoelectric micromachined ultrasonic transducers for parametric array transducers need DC-biased voltage driving signals in order to get high-directional quality-sound features. The existing power amplifier such as class A amplifiers has low efficiency and require large volume heatsinks. To overcome the above-mentioned disadvantages of the conventional amplifier, this paper proposes a new power amplifier system. The proposed power amplifier system ensures high linearity of output characteristic by utilizing the push-pull class B type amplifier. Furthermore, the proposed power amplifier system gets high efficiency because it contains the DC-DC converter-type power supply which can perform energy recovery and envelope tracking function. Also the paper suggests the detailed circuit topology. Its characteristics are verified by the detailed experimental results.

Design of the Zero Location for Minimizing the Peak Overshoot of Second Order Discrete Systems (이차 이산시스템의 Peak Overshoot을 최소화하기 위한 영점의 위치 설계)

  • Lee, Jas-Seok;Chung, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.512-514
    • /
    • 1999
  • The damping ratio $\zeta$ of a continuous 2nd order response which passes all the points of the discrete response of a 2nd order discrete system(envelope curve) is a function of only the location of the closed-loop pole and ie not at all related to the location of the zero. And the peak overshoot of the envelope curve is uniquely specified by the damping ratio $\zeta$, which is a function of solely the closed-loop pole location, and the angle $\alpha$ which is determined by the relative location of the zero with respect to the closed-loop complex pole. Therefore, if the zero slides on the real axis with the closed-loop complex poles being fixed, then the angle $\alpha$ changes however the damping ratio $\zeta$ does not. Accordingly, when the closed-loop system poles are fixed, the peak overshoot is function of $\alpha$ or the system zero. In this thesis the effects of the relative location of the zero on the system performance of a second order discrete system is studied.

  • PDF

Full-scale Mock-up Measurement of a Double Glazed Window System Equipped with Sunlight Controls (광기능성 창호시스템의 동절기 채광특성에 관한 목업연구)

  • Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.35-42
    • /
    • 2008
  • Besides genuine skin and clothes, it is called that building is third skin for us. That means the skin of buildings is the most important factor for our man-made environment. The issues in designing the building envelope include the insulation, infiltration, ventilation and bridging in windows. Getting light into the space safely and providing views to outdoor, additionally, are key things with the building envelope design. A deep-rooted preference for full view is still alive with large area of glass. Balcony expansion is legalized in apartment houses, which causes lots of environmental problems. Without balcony space, the adjacent space to unshaded window is exposed to the direct sun. A window can have many layers and the inner space can be utilized with an automatic blind system. Recently, the refurbished version of a double-glazed window system has been developed for the purpose of minimizing energy loss occurred around windows. For the better daylight control with equipped blind system, a set of adjustment technique of blind slats was tested in a mock-up building and recommended the detail operation. Not surprisingly, the optimized blind system can be oriented to enhance the uniformity in light distribution and direct glare from the sky as well..

Analysis on the Building System Integration Methods of the Salk Institute for Biological Studies (솔크 생물학 연구소에 적용된 건물시스템 통합기법 분석에 관한 연구)

  • Choi, Joon Sung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.59-68
    • /
    • 2018
  • Salk Institute for Biological studies is widely considered as architectural masterpiece of Louis Kahn's. Its iconic plaza with symmetrical concrete structures, overlooking the Pacific ocean in La Jolla, has been acclaimed as a facade to the sky. Little has been written on Kahn's achievements in the building system integration in order to bridge the gap between technology and design. This paper explores the technical issues, the design intents, and the major building systems to identify the Kahn's integration methods between building systems. The project is analysed into four major systems; structure, mechanical, envelope, and interior system. The integration methods of building systems are investigated in physical, visual, and functional aspects. The most distinguished cases of building system integration are the introduction of the interstitial floors between the laboratories and the creation of the smooth and warm materiality of exposed concrete walls. Kahn proposed open floor plans for the laboratories which are capable of easily adapting to changing needs. He also introduced the interstitial floors which are framed of the vierendeel truss systems and deliberately overlapped the structure systems with the mechanical systems such as ducts, water pipes, and electric conduits. The exposed concrete walls mixed with pozzolan ashes look very much like granite or limestone as the result of the physical and visual integration between structure, envelope, and interior systems.

Characterization of Monoclonal Antibody Specific for Hepatitis C Virus E2 Envelope Protein (Hepatitis C Virus E2 외피항원에 대한 단일클론항체의 특성 연구)

  • Park, Joon-Sang;Lee, Bum-Young;Chung, Soo-Il;Min, Mi-Kyung
    • The Journal of Korean Society of Virology
    • /
    • v.27 no.1
    • /
    • pp.9-17
    • /
    • 1997
  • Hepatitis C virus (HCV) E2 protein is known to be one of putative envelope proteins. To develop a sensitive detection method for HCV infected tissues and cells, monoclonal antibodys (MAbs) to the E2 protein of HCV were prepared from mice immunized with recombinant baculovirus-expressing E2 protein (Bac-E2). Several hybridoma clones secreting various levels of MAb were isolated and isotypes of these MAb were determined. One clone (L.2.3.3) was used for ascites production and the E2-MAb was purified and characterized. The L.2.3.3 reacted well with both Bac-E2 and E. coli expressed glutathione-S-transferase-E2 (GST-E2) fusion proteins. Using HCV patient sera, E2 envelope protein was found to be localized in the cell membrane boundary both in CHO cells and insect cells which express HCV E2 protein. Similar result was obtained when same cells were treated with the MAb L.2.3.3. These results demonstrated that Bac-E2 protein is capable of eliciting high titer antibody production in mice.

  • PDF

A Study on the Non-residential Building Envelope Remodeling for Energy Efficiency (비주거용 건물의 외피 리모델링을 통한 에너지성능향상 방안에 관한 연구)

  • Jang, Hyun-Sook;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.3-12
    • /
    • 2012
  • The slowdown of private building industry resulted in growth of remodeling market as a way to improve energy performance. Remodeling is considered more cost-effective and eco-friendly approach for energy efficient building than new construction. Since 2008, Seoul has promoted Building Retrofit Project (BRP) preponderantly to attract energy-saving renovation by supporting building owners to switch building system into energy-saving system when they remodel their old buildings. According to 2012 press release, 254 Private sectors participated in this green building project and annually reduced 41000ton of greenhouse gas emission, 14000TOE, which also result in 7.5 billion won energy cost savings per year. The paper focuses on the building envelope remodeling as a way to improve energy efficiency. Different components of the building envelope such as wall insulation, window, and shading, were applied to the baseline model and the comparison was analyzed to come up with the ideal solution. This study only assesses the building envelope as to suggest the way to redesign the better energy performing building. Offering solution focusing on the architectural feature is essential because it will provide basic information and standard when remodeling a building for energy efficiency, especially, for the nonresidential buildings used as rental offices.

Envelope Elimination and Restoration Transmitter for Efficiency and Linearity Improvement of Power Amplifier (전력증폭기의 효율 및 선형성 개선을 위한 포락선 제거 및 복원 송신기)

  • Cho, Young-Kyun;Kim, Changwan;Park, Bong Hyuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.292-299
    • /
    • 2015
  • An envelope elimination and restoration transmitter that uses a tri-level envelope encoding scheme is presented for improving the efficiency and linearity of the system. The proposed structure amplifies the same magnitude signal regardless of the input peak-to-average power ratio and reduces the quantization noise by spreading out the noise to the out-of-band frequency, resulting in the enhancement of power efficiency. An improved linearity is also obtained by providing a new timing mismatch calibration technique between the envelope and phase signal. Implementation in a 130 nm CMOS process, transmitter measurements on a 20-MHz long-term evolution input signal show an error vector magnitude of 3.7 % and an adjacent channel leakage ratio of 37.5 dBc at 2.13 GHz carrier frequency.

A Comparison with SNR Performance of Coherent Integration and Non-coherent Integration to Estimate Target Detection Range in Radar System (레이더 시스템에서 목표물 탐지 거리 추정을 위한 코히런트 집적과 비 코히런트 집적의 SNR 성능 비교)

  • Ga, Gwan-U;Ham, Sung-Min;Lee, Kwan-Hyeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.2
    • /
    • pp.86-91
    • /
    • 2014
  • This paper compare with SNR performance of coherent integration and non-coherent integration in radar system. This paper to prevent distortion of transmit signal and radar return in radar system is used to pulsed waveform. This paper to estimate target detection range and to compare with SNR performance used to coherent integration performed before the envelope detector and non-coherent integration processed after the envelope detector. Through simulation, SNR performance of coherent integration and non-coherent integration were comparatively analyzed. SNR performance of coherent integration is good proof higher than non-coherent integration.

Freeform 3D Coordinate Control Technology using CNC Twisted Tube Method -Focused on The ARC in DaeGu- (CNC Twisted Tube공법을 이용한 비정형 3차원 좌표제어 기술 -대구 대표물문화관(디아크)를 중심으로-)

  • Kim, Sung-Jin;Ryu, Geun-seok;Ryu, Han-Guk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.227-228
    • /
    • 2012
  • In contemporary architectural practice, flat sections and plan drawings are no longer a primary means of representation and communication with participants. A typical building design has an ornamental exterior wall system and a roof system that should have water-proof quality and drainage function. By comparison, distinction between exterior wall and roof are unclear in freeform buildings, and they are integrated into a concept of a building envelope. This study is to propose 3D coordinate control technology for freeform structure by CNC curved tube method in order to develop a BIM-based envelope design and construction method for freeform building. Because a much wider freeform building construction can be achieved with correct 3D data and easy-to-implement in construction field, the proposed 3D coordinate control technology is highly recommended for practical use instead of the conventional CAD system.

  • PDF

테레비젼 신호중단에 있어 화질에 영향을 주는 요인에 관한 연구

  • 김원후
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.1 no.1
    • /
    • pp.23-31
    • /
    • 1976
  • When Television signal of VHF and UHF channel is retransmitted at the relay system with 6MHz Bandwidth including video and aural signals, the image is often affected with the unnatural changes of output amplitude frequency response within ttle region of dual sideband near to the carrier frequency. These phenomena are caused by the unnecessary lower sideband due to the spurious emission at the local oscillator, the nonlinear distortion in the linear amplifier, the intermoudulation distortion with the components of neighboring signal, the AM-PM conversion, and the envelope delay distortion. From the output characteristics, considering above results, the chief cause is caused by nonlinear response and has an effect on the bias states. Finally, it is confirmed that the effects on neighboring signal appear high in case of Down conversion than Up conversion and obtained the method for reducing the effects on the system.

  • PDF