• Title/Summary/Keyword: Envelope

Search Result 1,547, Processing Time 0.024 seconds

POLARIZATION OF $H_{\alpha}$ WINGS RAMAN-SCATTERED IN SYMBIOTIC STARS (공생별에서의 $H_{\alpha}$날개의 편광연구)

  • BAK JIH-YONG;LEE HEE-WON
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc1
    • /
    • pp.147-151
    • /
    • 2000
  • Symbiotic stars, believed to be binary systems of a mass-losing giant and a white dwarf with an emission nebula, are known to exhibit very broad wings around Hex that extend to $\~10^3km\;s^{-1}$. The wing formation mechanism is not a settled matter and recently Lee (2000) proposed that Raman scattering of Ly$\beta$ by neutral hydrogen is responsible for the broad H$\alpha$ wings. In this model, it is predicted that. the Hex wings will be polarized depending on the geometric and kinematic distribution of the scatterers relative to the UV emission region. In this paper, we investigate the polarization of Hex wings in symbiotic stars. Noting that many symbiotic stars possess bipolar nebular morphology, we assume that the distribution of neutral scatterers follows the similar pattern with a receding velocity of several tens of km $s^{-1}$ that mimics the expansion of the neutral envelope of the nebula. It is found that the red wing is more strongly polarized than the blue and main part and that the polarization direction is along the equatorial plane. We obtain a typical degree of polarization $\~10$ percent, however, it varies depending on the detailed distribution of H I scatterers We conclude that spectropolarimetry will provide very important information on the origin of the Hex wings.

  • PDF

SPECTRA OF CHROMOSPHERICALLY ACTIVE STARS (채층 활동이 강한 별들의 분광선)

  • KANG YOUNG WOON;KIM HOIL;LEE WOO BAIK;OH KYU DONG
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc1
    • /
    • pp.93-102
    • /
    • 2000
  • We have reviewed the magnetic activity in close binaries. Solar like magnetic activity indicators such as photometric spots, chromo spheric emission, coronal X-ray and radio emission, and flare activity are commonplace in many cool stars with convective envelopes. Using the UV spectra we confirmed the strength of stellar activity increases with more rapid rotation and later spectral types which corresponds to the increasing depth of the star's convective envelope. Apart from very young stellar objects such as T Tauri stars, the stars with the highest levels of activity are close binary systems composed of cool stars, i.e., the chromospherically active binaries such as RS CVn, BY Dra, W UMa and related systems. The IUE low and high dispersion spectra of V711 Tau, VW Cep and SW Lac are used for ultraviolet photometry and for a variation study of chromospheric activity. Evidence of chromospherically activity is indicated by the intensity variation of the Mg II emission line with orbital phase.

  • PDF

A Multi-wavelength Study of a Pair of Interacting BCDs: ESO 435-IG20 and ESO 435-IG16

  • Kim, Jinhyub;Chung, Aeree;Sung, Eon-Chang;Staveley-Smtih, Lister
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.49-49
    • /
    • 2014
  • Blue Compact Dwarf galaxies (BCDs) are low-mass galaxies with recently enhanced star formation activity. Since the discovery of old stellar population in the BCDs, a number of hypotheses have been suggested as the origin of the current active star formation. One theory is tidal interactions such as fly-by and merger. In this study we test this hypothesis using a pair of BCDs, ESO 435-IG20 and ESO 435-IG16 that are separate by only ~80 kpc in projection at a similar redshift (at a ~9 Mpc distance). In the HIPASS survey, intergalactic atomic hydrogen envelope has been found to be covering both galaxies, making the pair a good candidate for the case where the star formation has been triggered by tidal interaction. We probe the gas morphology and kinematics of the BCD pair using ATCA HI data in order to find the evidence of tidal interaction. We also estimate star formation rates in the pair based on Ha emission and UV continuum, and compare with other dwarf galaxies to investigate how responsible the tidal interaction is for the enhanced star formation in this case.

  • PDF

A Standard Study for Improving Thermal Performance of the Hot and Cold Water Pipe Insulation in Buildings (건물 냉난방수배관의 단열성능 향상을 위한 기준 연구)

  • Choi, Seung-Hyuck;Gim, Yu-Seung;Yun, Hi-won;Ryu, Hyung-Kyou
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.21-30
    • /
    • 2017
  • Recently, It has increased the importance of building energy saving. Pipe insulation as well as building envelope insulation is to improve energy efficiency and reduce the energy loss. However, there continues to use the old standard for pipe insulation that is one of the most important elements in energy savings in buildings. The purpose of this study is to propose suitable pipe insulation thickness for reducing building energy use. The study also reviews pipe insulation thickness standard in accordance to Korea standard, ASHRAE 90.1 and BS5422 and analyzed through thermal simulation. As a result, it is necessary to apply the performance design method of the pipe insulation thickness to reduce the energy loss of the piping.

A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types (케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구)

  • Choi, Taehwoan;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior (ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구)

  • Kim, Young-Ho;Lee, Yong-Soo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.

Hybrid MIMO Antenna Using Interconnection Tie for Eight-Band Mobile Handsets

  • Lee, Wonhee;Park, Mingil;Son, Taeho
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.185-193
    • /
    • 2015
  • In this paper, a hybrid multiple input multiple output (MIMO) antenna for eight-band mobile handsets is designed and implemented. For the MIMO antenna, two hybrid antennas are laid symmetrically and connected by an interconnection tie, thereby enabling complementary operation. The tie affects both the impedance and radiation characteristics of each antenna. Further, printed circuit board (PCB) embedded type is applied to the antenna design. To verify the results of this study, we designed eight bands-LTE class 12, 13, and 14, CDMA, GSM900, DCS1800, PCS, and WCDMA-and implemented them on a bare board the same size as the real board of a handset. The voltage standing wave ratio (VSWR) is within 3:1 over the entire design band. Antenna isolation is less than -15 dB at the lower band, and -12 dB at the WCDMA band. Envelope correlation coefficient (ECC) of 0.0002-0.05 is obtained for all bands. The average gain and efficiency are measured to range from -4.69 dBi to -2.88 dBi and 33.99% to 51.5% for antenna 1, and -4.74 dBi to -2.97 dBi and 33.45% to 50.49% for antenna 2, respectively.

Intelligent AGC Circuit Design (지능형 AGC 회로 설계)

  • Zhang Liang;Kim Jong-Won;Seo Jae-Yong;Cho Hyun-Chan;Jeong Goo-Chul
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.302-305
    • /
    • 2006
  • A problem that arises in most communication receivers concerns the wide variation in power level of the signals received at the antenna. These variations cause serious problems which can usually be solved in receiver design by using Automatic Gain Control (AGC). AGC is achieved by using an amplifier whose gain can be controlled by external current or voltage. However, the AGC circuit does not respond to rapid changes in the amplitude of input. If input changes instantaneously, then even if op-amps could follow the change, the envelope detector capacitor could not, since the capacitor's voltage could not change instantaneously. To alleviate this deficiency, we present Improved Automatic Gain Control Circuit (IAGCC) replacing AGC circuit to FLC.

  • PDF

Performance of 2-Carrier DS system and its MODEM designed for Power Line Transmission (전력선 통신을 위한 2-반송파 DS방식의 특성과 MODEM의 구현)

  • 김인태;이무영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.3
    • /
    • pp.582-590
    • /
    • 1994
  • This paper introduce a highly verstile and simple data transmission system designed for commercial power distribution lines. The system operates on the DSSS principle but utilizes two independent carrier frequencies each represents polarity of DS MODEM outiputs. At the receiving terminal, outputs of two envelope detectors are directly applied to separate DS correlators before the two components are compared. The recovered signals which represents data and line noise are then compared at comparator. With the noise power greatly rudused at the correlator, the error rate of the data observed at comparator desplays great improvement comparing to the conventional FSK-DS system in which the detector output are compared before the correlator stage. Despite its simplest structure, the prototype MODEM transmitts 2400 bps with the error rate 10 , about 10dB improved compared to conventional FSK system.

  • PDF

A Study on Thermal Performance Analysis of the Sustainable Clayed Hollow Block Wall (친환경 점토질 다공블럭 벽체의 열성능 분석 연구)

  • Jang, Yong-Sung;Park, Hyo-Soon
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.65-70
    • /
    • 2004
  • The purpose of this study is to analysis the thermal performance of the clayed hollow block wall. Its thermal performance was evaluated comparison with the cement block wall, it was generally used in building envelope. To that end, we conducted a insulation performance experiment and heating and cooling load simulation for a respective wall. In addition, we calculated a construction cost for each other's wall. The results of this study can be summarized as follows. (1) According to experiment of a insulation performance, coefficient of overall heat transmission of the cement block wall and clayed hollow block wall was calculated respectively $2.72W/^2K$ and $1.42W/^2K$. (2) The annular load saving of the clayed hollow block wall was evaluated 1.5% larger than its of the cement block wall. (3) The construction cost of the clayed hollow block wall was calculated 73% more expensive than its of the cement block wall. (4) The construction cost of the clayed hollow block composite wall was calculated 13.7% more expensive than its of the cement block composite wall.