• Title/Summary/Keyword: Envelope

Search Result 1,547, Processing Time 0.026 seconds

Evaluation and Analysis of Building Energy Rating System Accroding to Insulation Performance of Building Envelope in Regional and Building Form of Apartment House (지역 및 주동형태별 공동주택 외피 단열 성능에 따른 건물에너지효율등급 평가 및 분석)

  • Kim, Min-Kyu;Park, Hyu-Soon;Song, Kyoo-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.49-54
    • /
    • 2013
  • In field of apartment housing currently, insulation technology is the most effective way because it is common to improve the thermal performance, therefore, it is contributed to energy saving as several regional insulation standards and legal mandate method. In addition, by applying of building energy efficiency rating certification system, it has inspired voluntary energy conservation commitment for the building owner or facility manager by making a plan to evaluate and verify building energy performance. However, these circumstances are not enough to acquire a grade 2 of higher information. Therefore, in this study, we analyzed the impact of building energy efficiency rating and confirmed reduction ratio compared to the standard housing on the basis of recent our nation building law when we had changed the shape of windows and wall insulation performance and shapes of housing.

A Comparative strudy on the Insulation Performance of the Super Window by Actual Survey and Simulation (초단열 슈퍼윈도우의 단열성능 실측과 시뮬레이션 비교 분석)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Jang, Cheol-Yong;Hong, Won-Hwa
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.231-235
    • /
    • 2009
  • According to flow of energy, the loss occurs through walls, roofs, windows and so on. Among these case, most of the loss that is about 45% occurs through windows. windows's U-value is six times higher than wall's one according to Building code, so the loss through windows accounts for very much rates. Currently, Exterior wall's U-value about building envelope is 0.35~0.58W/ mK, but windows's one is 3.3W/ mK. It means that the loss through windows occupy very much amounts relatively. Therefore, the solution is required to reduce energy loss and increasing displeasure caused by excessive influx of solar energy through windows, to solve the problems Like decoloration on indoor furniture an clothes by harmful ultraviolet rays, air conditioning and increased cost. Therefore, on this paper, Thermal Performance was evaluated through actual test about high insulation Super Window which can improve thermal performance and the Simulation result was compared with actual resul by using Simulation program WINDOW and THERM.

  • PDF

Ciprofloxacin Resistance by Altered Gyrase and Drug Efflux System in Pseudomonas aeruginosa

  • Cho, Myung-Sun;Kim, Do-Yeob;Kong, Jae-Yang;Yang, Sung-Il
    • Archives of Pharmacal Research
    • /
    • v.18 no.3
    • /
    • pp.173-178
    • /
    • 1995
  • Ciprofloxacin resistance mechanisms were studied by investigating the inhibitory effect of ciprofloxacin on the gyrase-mediated DNA supercoiling and the intracellular accumulation of ciprofloxacin in clinical isolates of Pseudomonas aeruginosa. A higher amount of ciprofloxacin was required to inhibit the gyrases purified from the ciprofloxacin-resistant strains than that from the sensitive strain. Reconstitution of heterologous gyrase subunits from different strains revealed alterations in the A and/or the B subunits of gyrase in these strains. In addition, the resistant strains accumulated approximately a half amount of ciprofloxacin inside the cells, compared to the sensitive strain. However, when the active efflux was blocked by carbonyl cyanide m-chlorophenyl hydrazone treatment, intracellular concentration of ciprofloxacin was elevated about 4-7 fold in these strains, while the sensitive strain was not significantly affected by this treatment, indicating that the ciprofloxacin-resistant strains developed a drug efflux system. Interestingly, these resistant strains expressed an envelope protein of approximately 51 kD. These studies suggest that alterations in the gyrase as well as the active drug-efflux system conferred dual ciprofloxacin resistance mechanisms to these clinical isolates of P. aeruginosa.

  • PDF

Performance Evaluation of BIPV Systems Applied in School Buildings (학교 건축에 대한 BIPV시스템의 성능 평가)

  • Park, Kyung-Eun;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.5
    • /
    • pp.14-23
    • /
    • 2004
  • Building-integrated photovoltaic(BIPV) systems can operate as a multi-functional building components, which generates electricity and serves as part of building envelope. It can be regarded as a new architectural elements, adding to the building's aesthetics. Besides of these benefits, the application of PV systems into school buildings tends to play an important role in energy education to students. In this context, this study aims to analyse the applicability of PV systems into school buildings. For an existing school building, four types of BIPV designs were developed; rooftops, wall-attached, wall-mounted with angle, and sunshading device. Based on energy modeling of those BIPV systems, the whole 60.1kWp rated PV installation is expected to yield about 65.6MWh of electricity, that is about 50% more than the annual electricity consumption of the school, 44MWh. It was also found that the applicability of the PV systems into the school building was very high, and the rooftop systems with the optimized angle was the most efficient in energy production, followed by sunshading, wall-mounted with angle and wall-attached. It concludes that school buildings have a reasonable potential to apply PV systems in the aspects of building elements and electricity production.

Simulation and Verification of the Received Signals in Rician Channel (라이시안 채널에서의 수신 신호 모의 실험 및 검증)

  • Lee, Bom-Son;Lee, Il-Yong;Park, Jung-Il;park, Kyung-Ryung;Yeon, Kwang-Il;Eo, Ik-Soo;Kang, In
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.3
    • /
    • pp.347-358
    • /
    • 1998
  • The possibility of modeling the complex and diversified radio environment using Rician channel has been considered. The signals received in Rician channel have been simulated using the computer simulator. The PDF(Probability Density Function of the Envelope amplitude), PSD(Power Spectral Density), LCR(Level Crossing Rate), ADF(Average Duration of Fades) and BER(Bit Error Rate) of the simulated signal have been compared with those of theory. They were shown to be in good agreement.

  • PDF

Dynamic Fracture Behavior of Some Polymeric Materials (고분자재료의 동적 파괴거동에 관한 연구)

  • 이억섭;한정우;한문식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1630-1641
    • /
    • 1995
  • The dynamic stress intensity factors (DSIF ; $K_{I}$$^{dyn}$) were studied in some polymeric materials using caustics method with a high speed camera system. Also crack tip propagation speed was measured by dynamic crack propagation velocity measuring device. To calculate DSIF a finite element analysis program-INha Stress Analysis Moving CRack(INSAMCR) was utilized. Dynamic fracture characteristics were investigated to verify a relationship between DSIF and crack tip propagation speed and acceleration in PMMA, Homalite-100 and Polycarbonate. The relationship between dynamic stress intensity factor and crack tip velocity revealed typical shapes. Measured crack tip acceleration data envelope converges to the zero level with increasing DSIF. Equivalently crack tip velocities show a wide spread range at low values of DSIF, but become a constant with a higher DSIF. $1.2MPa{\sqrt{m}}$, $1.4MPa{\sqrt{m}}$ and $1.3 MPa{\sqrt{m}}$ were obtained as $K_{I}$$^{dyn}$ values to arrest the dynamic crack for PMMA, Homalite-100 and Polycarbonate, respectively. INSAMCR was run to verify experimental results in PMMA and shows good agreementment.

A Study on the Gain Tuning of Fuzzy Logic Controller Superior to PI Controller in DC Motor Speed Control (직류 전동기 속도 제어에서 PI 제어기보다 우수한 퍼지 논리 제어기의 이득 선정을 위한 연구)

  • Kim, Young-Real
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.30-39
    • /
    • 2014
  • Through a lot of papers, it has been concluded that fuzzy logic controller is superior to PI controller in motor speed control. Although fuzzy logic controller is superior to PI controller in motor speed control, the gain tuning of fuzzy logic controller is more complicated than that of PI controller. In this paper, using mathematical analysis of the PI and fuzzy controller, the design method of the fuzzy controller that has the same characteristics with the PI controller is proposed. After that, we can design the fuzzy controller that has superior performance than PI controller by changing the envelope of input of fuzzy controller to nonlinear, because the fuzzy controller has more degree of freedom to select the control gain than PI controller. The advantage of fuzzy logic controller is shown through mathematical analysis, and the simulation result using Matlab simulink has been proposed to show the effectiveness of these analysis.

Numerical Study on Ricochet Behavior with Inclined Impact of Polycabonate Plates (폴리카보네이트 판의 경사충격에 의한 도비 거동 수치연구)

  • Yang, Tae-Ho;Lee, Young-Shin;Jo, Jong-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, the numerical simulation using AUTODYN-3D program was investigated angle trajectory prediction for inclined impacts of projectiles. The penetration and perforation of polycarbonate plate by 7.62 mm projectile was investigated numerically. The characteristic structure of the projectile's trajectory in the polycabonate plates was studied. Two combined failure criteria were used in the target plate, and the target plate was modeled with the properties of polycarbonate for simulating the ricochet phenomenon. The effect of the angle of inclination on the trajectory and kinetic energy of the projectile were studied. The dynamic deformation behaviors tests of polycabonate were compared with numerical simulation results which can be used as predictive purpose. From the simulation, the ricochet phenomenon was occurred for angles of inclination of $0^{\circ}{\leq}{\theta}{\leq}20^{\circ}$. The projectile perforated the plate for ${\theta}{\leq}30^{\circ}$, thus defining a failure envelope for numerical configuration. The numerical analyses are used to study the effect of the projectile impact velocity on the depth of penetration (DOP). It can be observed that the residual velocities were almost linear relative to penetration velocities. It means that polycarbonate has high resistance at higher velocities.

Parameter and Brightness Characteristic of Antena according to Coil turns on Electrodeless Fluorescent Lamp (무전극 램프 안테나의 권선수에 따른 휘도와 파라미터 특성)

  • Yang, Jong-Kyung;Choi, Gi-Seung;Pack, Gwang-Hyeon;Choi, Yong-Sung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.281-284
    • /
    • 2004
  • In Recent, it became necessary to envelope the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long-lifetime. Especially, in the electrodeless fluorescent lamp which used H-mode, efficiency of lamp is decided from matching parameter of antena and inverter So it is of the utmost importance to design antena and inverter. Therefore, this paper used a transformer principle for efficiency rising of electrodeless fluorescent lamp and interpreted an equivalent circuit, used an impedance analyzer in order to confirm a performance enhancement of lamp along design of antenna, and confirmed parameter characteristic of R, L, C, Z, Phase, Q-factor along a change of magnetic flux density. Also, this paper confirmed a luminance characteristic of electrodeless lamp along parameter change with measuring optical characteristic along a change of magnetic flux density.

  • PDF

Evaluation of Indoor Thermal Environment according to Type and Color of Blinds Installed in the Classroom (교실에 설치된 블라인드의 유형과 색상에 따른 실내 온열환경 평가)

  • Kwon, Daehyeok;Lee, Jae-Ro;Oh, Juseok;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.3
    • /
    • pp.224-232
    • /
    • 2017
  • Building energy saving have been put effort in a long time since buildings consume about 40.6% of total energy use, where heating, cooling and electrical lighting requirement results in energy consumption of building significantly. The window is an important part of building envelope, it usually brings a certain heat load from solar radiation while it allows light passing through, and properly leads to overheating in summer, hence the cooling load increase sand cause of thermal uncomfortable factor. The purpose of this study was to evaluate internal shade performance according to color and materials. There is growing interest in improving the sense of comfort among students who spend most of their time in the classroom. The study examined thermal environment and light environmental performance according to the color and materials of internal blinds to the school classroom. The results of this study were as follows; Among wooden blinds, aluminium blinds, and polyester blinds, the aluminium blinds were most excellent. In addition, among white blinds, light brown blinds, dark brown blinds, the light brown were most excellent.