• Title/Summary/Keyword: Enthalpy efficiency

Search Result 77, Processing Time 0.024 seconds

The Novel Configuration for Building Energy System Including Build ins Microgrid (빌딩 마이크로그리드가 포함된 새로운 빌딩에너지 시스템 구축방향에 관한 연구)

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.235-240
    • /
    • 2008
  • The recent development of efficient thermal prime movers for distributed generation id changing the focus of the production of electricity from large centralized power plants to local generation units scattered over the territory. The scientific communality is addressing the analysis and planning of the distributed energy resources(der) with wide spread approaches, taking into account technical, environmental, economical and social issues. The coupling of cogeneration system to absorption/electric chillers or heat pumps as well as the interactions with renewable sources, allow for setting up multi-generation systems for building cooling heating and power(BCHP) systems of different energy vectors such as electricity, heat(at different enthalpy levels), cooling power, hydrogen, various chemical substances and so forth. Adoption of the composite multi-generation systems may lead to significant benefits in term of higher efficiency, reduced $CO_2$ emissions and enhanced economy. This paper outlines the main aspects of the BCHP system framework, illistrating its characteristics and summarizing the relevant distributed multi-generation structures.

  • PDF

Development of Freeze Drying Analysis Program using Fixed Grid (고정격자를 이용한 동결건조 해석프로그램의 개발)

  • Nam Jin Hyun;Song Chi Sung;Kim Charn-Jung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.923-931
    • /
    • 2004
  • A multi-dimensional freeze drying analysis program, which took simultaneous heat and mass transfer, sublimation of ice and motion of sublimation front into full account, was developed using finite volume method with fixed grid. The effect due to the motion of sublimation interface was modeled by an enthalpy formulation streamlined for the freeze drying problems. The efficiency and accuracy of the program was validated by solving one- and two-dimensional freeze drying problems frequently encountered in industrial processes. Finally, the freeze drying processes of cylinder and slab objects with permeable side surfaces were simulated, which demonstrated the capability of the present analysis program in solving multi-dimensional freeze drying problems with complex sublimation interface configurations.

Performance Change of Gas Turbine with a Evaporation Cooling System in Summer Season (하절기 기화냉각장치 설치에 따른 가스터빈 성능변화)

  • Chung, Hyeon-Jo;Yoo, HoSeon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2017
  • This study analyzed the change of gas turbine performance with air temperature decrease by the evaporation cooling system in summer season. Gas turbine performance was tested on the condition that ambient temperature is $29{\pm}1^{\circ}C$. As a result, Air temperature at the compressor inlet was decreased by $4.12^{\circ}C$ after the installation of evaporation cooling system. Decreased air temperature followed by increased air density affected gas turbine performance, Which increased compressor pressure ratio by 0.27, improved compressor efficiency of 0.29 %p, improved gas turbine enthalpy drop efficiency of 0.31 %p, improved the gas turbine efficiency by 0.44 %p, improved electric power output by 4,489 kW. On the other side, the influence of the humidity increase and flow resistance increase was negligible.

  • PDF

Thermodynamic Analysis on Organic Rankine Cycle Using Exhaust Gas of the Chimney in a Resource Recovery Facility (폐기물 소각시설 굴뚝의 배기가스를 이용한 유기랭킨사이클 시스템의 열역학적 해석)

  • Kim, Sunhee;Sung, Taehong;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.27-35
    • /
    • 2017
  • The amount and quality of waste heat from a resource recovery facility were measured. The temperature of exhaust gas was $176.6^{\circ}C$ and the amount of that was 13.8 kg/s. This research designed a waste heat recovery system whose working fluid is R-245fa. It simulated three study cases as follows. In simulation of a basic ORC system, the turbine power output and thermal efficiency were respectively 96.56 kW, 14.3%. In simulation of a superheater connection, 0.09% of efficiency could be improved due to the increase of enthalpy by overheating of working fluid, but the obtained output was decreased with 16.58kW because of the decrease of working fluid mass. In simulation of a process heater connection, efficiency was increased up to 38.51%.

Analysis of Heat Release Rate with Various Diameter of Heptane Pool Fire Using Large Scale Cone Calorimeter (헵탄의 화원 직경 변화를 고려한 대형콘칼로리미터의 발열량 측정 결과 분석)

  • You, Woo Jun;Nam, Dong-Gun;Youm, Moon Cheon;Kim, Sung-Chan;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.1-7
    • /
    • 2014
  • The present study has been conducted to analyse the effects of various pool diameters on the measurement of heat release rate (HRR) of heptane fire using large scale cone calorimeter (LSC). The burning rate which is the major parameter for HRR compared with the previous model suggested by A. Hamins. The combustion efficiency for heptane by oxygen consumption method is about 91%, which is almost same with the previous results of 92% suggested by J. Gore. The convective HRR by enthalpy consumption method was 54% lower than HRR by oxygen consumption method. This results are practical use for establishing the reliability of heat release rate for fire experiment.

Adsorption Characteristics of Methylene Blue and Phenol from Aqueous Solution using Coal-based Activated Carbon (석탄계 활성탄에 의한 수중의 메틸렌블루와 페놀 흡착 특성)

  • Lee, Song-Woo;Kam, Sang-Kyu;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.22 no.9
    • /
    • pp.1161-1170
    • /
    • 2013
  • The efficiency of coal-based activated carbon in removing methylene blue (MB) and phenol from aqueous solution was investigated in batch experiments. The batch adsorption kinetics were described by applying pseudo-first-order, pseudo-second-order, and first order reversible reaction. The results showed that the adsorption of MB and phenol occurs complexed process including external mass transfer and intraparticle diffusion. The maximum adsorption capacity obtained from Langmuir isotherm was 461.0 mg/g for MB and 194.6 mg/g for phenol, respectively. The values of activation parameters such as free energy (${\Delta}G^0$), enthalpy (${\Delta}H^0$), and entropy (${\Delta}S^0$) were also determined as -19.0~-14.9 kJ/mol, 25.4 kJ/mol, and 135.2 J/mol K for MB and 51.8~54.1 kJ/mol, -29.0 kJ/mol, and -76.4 kJ/mol K for phenol, respectively. The MB adsorption was found to be endothermic and spontaneous process. However, the CV adsorption was found to be exothermic and non-spontaneous process.

Effect of Scale and Geometry on the Performance of Heat-Recirculating Swiss roll combustors for Micro Power Generation Applications (마이크로 동력발생용 소형 스위스롤 연소기의 크기와 형상 효과에 대한 연구)

  • Oh, Hwa-Young;Huh, Hwan-Il;Ronney, Paul D.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Combustion and extinction limits in heat-recirculating excess enthalpy reactors employing both gas-phase and catalytic reaction have been examined with an emphasis Reynolds number (Re) effects and possible application to microscale combustion devices. In this paper, geometrically similar reactors of different physical sizes and different numbers of turns were tested with the aim of estimating for combustor characteristics. Combustion efficiency is estimated by measuring exhausted gases through the gas chromatograph. From these results the effect of scale and number of turns are demonstrated and optimal operating conditions for Swiss roll combustors are identified.

Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics) (PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

An analysis on the characteristics of superheater organization of ORC system for marine waste heat recovery system(WHRS) (선박폐열회수(WHRS) ORC 시스템의 과열기 구성에 따른 특성 해석)

  • Kim, Jong-Kwon;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • This research designed Waste Heat Recovery System(WHRS) generation system of 250kW whose working fluid is R-245fa and studied on cycle characteristics by superheater organization. It simulated two conditions; series connection and parallel connection between superheater and evaporator. In simulation of series connection of superheater and evaporator, output of 4.7% could be improved because of the increase of enthalpy by overheating of working fluid. When setting 250kW for target output, cycle flux could be reduced by 4.1%. When setting 250kW as a target output of cycle In parallel connection simulation of superheater and evaporator, cycle flux was reduced as flux of heat source fluid for superheater was increased. So, the maximum 7.9% of working fluid pump's electric power was reduced and there was no big change in cycle efficiency and net efficiency by flux ratio.

Preparation and Application of Polyurethane-urea Microcapsules Containing Phase Change Materials

  • Kwon Ji-Yun;Kim Han-Do
    • Fibers and Polymers
    • /
    • v.7 no.1
    • /
    • pp.12-19
    • /
    • 2006
  • For thermal adaptable fabrics, the polyurethane-urea microcapsules containing phase-change materials (PCMs: hexadecane, octadecane and eicosane) were successfully synthesized by interfacial polycondensation using 2,4-toluene diisocyanate (TDI)/poly(ethylene glycol) (PEG400)/ethylene diamine (EDA) as shell monomers and nonionic surfactant NP-12 in an emulsion system under stirring rates of $3,000{\sim}13,000$ rpm. The mean particle size of microcapsule decreased significantly with increasing the stirring rate up to 11,000 rpm, and then leveled off. The mean particle size increased with increasing the content and molecular weight (eicosane > octadecane > hexadecane) of PCMs at the same stirring rate. The mean particle sizes of microcapsules were found to decrease with increasing the NP-12 content up to 1.5 wt%, and thereafter increased a little. It was found that the melting temperature ($T_m$) and crystallization temperature ($T_c$) of three kinds of encapsulated PCMs and their enthalpy changes (${\Delta}H_m,{\Delta}H_c$) increased with increasing PCM contents. The encapsulation efficiencies (Ee) of hexadecane microcapsule linearly increased with increasing the content of hexadecane. It was found that the stable microcapsule containing 50 wt% of hexadecane could be obtained in this study. However, Ee of octadecane and eicosane microcapsules increased with increasing PCM's contents up to 40 wt%, and then decreased a little. By considering the encapsulation efficiency, it was found that the maximum/optimum contents of octadecane and eicosane microcapsules were about 40 wt%. By the dynamic thermal performance test, it was found that the maximum buffering levels of Nylon fabrics coated with hexadecane, octadecane, and eicosane microcapsules were about $-2.4/+2.9^{\circ}C,\;-3.6/+3.6^{\circ}C\;and\;-4.0/+4.7^{\circ}C$, respectively.