• Title/Summary/Keyword: Enthalpy Control

Search Result 64, Processing Time 0.032 seconds

Physicochemical Characteristics of Acid Thinned and High Pressure Treated Waxy Rice Starch for Yugwa (Korean Rice Snack) Production

  • Cha, Jae-Yoon;Choi, Ae-Jin;Chun, Bo-Youn;Kim, Min-Ji;Chun, Hyang-Sook;Kim, Chul-Jin;Cho, Yong-Jin;Kim, Chong-Tai
    • Food Science and Biotechnology
    • /
    • v.16 no.6
    • /
    • pp.943-947
    • /
    • 2007
  • The acid modification of waxy rice starch was conducted to improve the yugwa production process. The intrinsic viscosity, paste viscosity, and differential scanning calorimetry characteristics of acid modified starch were measured, and bandaegi and yugwa prepared from acid modified starch were evaluated. The intrinsic viscosities of acid thinned starches were 1.48, 1.27, 1.15, and 0.91 mL/g after reaction times of 1, 2, 3, and 4 hr, respectively. The gelatinization enthalpy was reduced from 16.3 J/g in native starch to 15.8, 15.3, 14.7, and 14.5 J/g in acid thinned starches as the time of acid thinning increased. The peak viscosity and final viscosity decreased with increasing the time of acid thinning, but the pasting temperature was slightly increased in acid thinned starches. The hardness of bandaegi from acid thinned starches under high pressure greatly decreased relative to the control, typical yugwa. Yugwa from acid thinned starch under high pressure maintained a homogeneous structure containing tiny and uniform cells similar to that of native waxy rice starch used for typical yugwa. Acid thinning under high pressure appears to be a good alternative to the existing steeping process for better yugwa quality.

Effects of Rice Bran Dietary Fiber Extract on Gelatinization and Retrogradation of Wheat Flour (미강 식이섬유 추출물이 밀가루의 호화 및 노화에 미치는 영향)

  • Kim, Young-Soo;Ha, Tae-Youl;Lee, Sang-Hyo;Lee, Hyun-Yu
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.464-469
    • /
    • 1997
  • Rapid visco-analyzer (RVA) and differential scanning calorimetry (DSC) were used to study the effect of rice bran dietary fiber extract on gelatinization and retrogradation of wheat flour. The addition of rice bran dietary fiber extracts from various heat treated bran into wheat flour caused to increase the pasting temperature, peak viscosity and final viscosity of RVA measurements. For gelatinization measured with DSC, mixtures of wheat flour and rice bran dietary fiber extract had slightly higher To (onset temperature) and Tp (peak temperature) values than those of control (wheat flour), and wheat flour/defatted rice bran dietary fiber extract mixture had the lowest enthalpy value. In comparison with gelatinization, the retrogradation endotherm of mixtures stored at $4^{\circ}C$ up to 4 weeks occurred at about $20^{\circ}C$ lower temperatures than gelatinization endotherm with broader shape and well-defined thermograms with storage time. The retrogradation of wheat flour was retarded greatly by addition of rice bran dietary fiber extract, and there was no big difference between 5% and 10% additions.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

Storage Quality Characteristics of Bread Added with Dried Mulberry Pomace (저장 중 건오디박 첨가 빵의 품질 특성)

  • Kim, Hyun Jeong;Shin, Suk Kyung;Kim, Mee Ree
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.12
    • /
    • pp.1972-1980
    • /
    • 2013
  • The purpose of this study is to evaluate the storage quality characteristics of bread with added dried mulberry pomace (DMP, 0, 1, 3 or 5%) during storage at $4^{\circ}C$ for 7 days. During the entire storage period, the moisture content was higher in breads containing DMP compared with the control bread. Textural properties by TPA showed that the hardness of DMP bread maintained a lower hardness than that of the control during the entire storage period. Moreover, DSC (Differential Scanning Calorimetry) result showed that ${\Delta}H$ (crystal melting enthalpy) of the bread containing DMP was lower than that of the control bread, which indicate the retarding of retrogradation. The sensory preference test results demonstrated that the bread with 3% DMP had higher scores in over-all preference than the others. These results suggest that DMP delays the retrogradation of bread during storage.

Quality Characteristic of Sulgidduk with Apple Pomace Dietary Fiber (사과박 식이섬유를 첨가한 설기떡의 품질특성)

  • Park, Young-Kyoung;Kim, Hee-Sun;Park, Hye-Young;Han, Gwi-Jung;Kim, Myung-Hwan
    • Food Engineering Progress
    • /
    • v.15 no.3
    • /
    • pp.250-256
    • /
    • 2011
  • This study was performed to analyze the quality characteristics of Sulgidduk added with different ratio 0, 10 and 15% (w/w) of apple pomace dietary fiber powder (DFP). Increasing DFP from 0% to 15% was decreased in color L* value from 87.9 to 65.9, while a* and b* values were increased from -1.9 to 5.9 and from 5.0 to 20.5, respectively. Scanning Electron Microscopy (SEM; ${\times}500$) showed that air cell size in the Sulgidduk surface increased as the DEP increased. On the other hand, control without DFP had a compact structure without air cell. Enthalpy by DSC showed that control without DFP, 10 and 20% DEP Sulgidduk after 3 days of storage were 4.83, 3.80 and 3.18 J/g at $4^{\circ}C$ and those of $25^{\circ}C$ were 1.14, 0.60 and 0.60 J/g, respectively. DEP had more effective on retarded retrogradation of Sulgidduk at $4^{\circ}C$ than that at $25^{\circ}C$. Hardness of 15% DEP Sulgidduk was around 42% compared to that of control without DFP after 3 days of storage at $4^{\circ}C$. In hedonic test, 15% DEP Sulgidduk showed the highest overall quality score among samples after making and storage 3 days at $4^{\circ}C$.

Process Parameters on Quality Characteristics of Jacopever (Sebastes schlegeli Hilgendorf) under Treatment of Hydrostatic Pressure (고압처리 공정변수가 조피볼락의 초기 품질특성에 미치는 영향)

  • Kim, Min-Ji;Lee, Soo-Jeong;Kim, Chong-Tai
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.3
    • /
    • pp.371-381
    • /
    • 2016
  • The present study investigated the effects of processing parameters such as time (10, 20, 30, 40 min), pressure (25, 50, 75, 100 MPa), and the salinity of brine (0~10%(w/v)) on jacopever (Sebastes schlegeli Hilgendorf) in order to establish optimization of the three factors using a high hydrostatic pressure (HHP) machine. To do so, it analyzed the quality characteristics of volatile basic nitrogen (VBN), trimethylamine (TMA), total bacterial counts, dynamic viscoelasticities, and differential scanning calorimetry (DSC) properties. First, when the time increased to 40 mins, by 10 min intervals, the total bacterial counts in HHP groups under $25^{\circ}C$, 100 MPa, and 4%(w/v) brine were significantly decreased except for the first 10 min in comparison to the control group. In regards to DSC properties, the onset temperature ($T_O$) of the first endothermal curve was significantly reduced. Second, when the pressure level increased up to 100 MPa by 25 MPa increments, the total bacterial counts in the HHP samples significantly decreased for 20 min at 50 MPa or higher. As the pressure increased, G', G" and the slope of tan ${\delta}$ decreased (except for 50 MPa). Third, in regards to the salinities of brine, when the HHP processing was treated at 100 MPa, $25^{\circ}C$ for 20 min, the total bacterial counts of all the HHP groups significantly decreased in comparison to those of the control group. A significant difference was found in the enthalpy of the second endothermic curve in the 6~10%(w/v) (except 7%(w/v)) HHP groups. Therefore, the salinity of the immersion water under the HHP condition was appropriate when it was lower than 6%(w/v). The present study demonstrated that the optimum parameter condition according to/under the condition of the microbial inhibition and economic effects using an HHP would be the reaction time for 20 min, reaction pressure at 100 MPa, and the salinity of 4%(w/v) brine.

Isolation and Physicochemical Properties of Rice Starch from Rice Flour using Protease (단백질분해효소에 의한 쌀가루로부터 쌀전분의 분리 및 물리화학적 특성)

  • Kim, ReeJae;Oh, Jiwon;Kim, Hyun-Seok
    • Food Engineering Progress
    • /
    • v.23 no.3
    • /
    • pp.193-199
    • /
    • 2019
  • This study aimed to investigate the impact of protease treatments on the yield of rice starch (RST) from frozen rice flours, and to compare the physicochemical properties of RST by alkaline steeping (control) and enzymatic isolation (E-RST) methods. Although the yield of E-RST, prepared according to conditions designed by the modified 23 complete factorial design, was lower than the control, the opposite trends were observed in its purity. E-RST (RST1, isolated for 8 h at 15℃ with 0.5% protease; RST2, isolated for 24 h at 15℃ with 1.5% protease; RST3, isolated for 24 h at 15℃ with 0.5% protease) with the yields above 50% were selected. Amylose contents did not significantly differ for the control and RST2. Relative to the control, solubilities were higher for all E-RST, but swelling power did not significantly differ for E-RST except for RST1. Although all E-RST revealed higher gelatinization temperatures than the control, the reversed trends were found in the gelatinization enthalpy. The pasting viscosities of all E-RST were lower than those of the control. Consequently, the enzymatic isolation method using protease would be a more time-saving and eco-friendly way of preparing RST than the alkaline steeping method, even though its characteristics are different.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Effect of Pretreatments on the Physicochemical Properties of Lotus Root Powder (전처리 방법에 따른 연근가루의 이화학적 특성)

  • Kim, Ok-Suk;Choi, Ok-Ja;Shim, Ki-Hoon
    • Food Science and Preservation
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2012
  • To enhance the application of lotus roots and to provide basic data for processed foods with lotus roots, lotus root powder was processed under four different conditions, and their physicochemical properties were analyzed as follows. In the Hunter's color value results, the salted sample had the highest L value, and the vinegared sample had the highest a and b values. The water-holding capacities of the salted, vinegared, and blanched samples were higher than that of the control sample. The amylase contents were in the 19.57-20.43% range but were not significant. The swelling power and solubility of the processed samples increased as the temperature rose. The blanched sample had the highest swelling power and solubility (65 and $60^{\circ}C$, respectively). The crystallinity of the processed samples, as determined via X-ray diffraction, reached their peak at $16.9^{\circ}$, and the other peaks at 14.6, 22.2, and $23.8^{\circ}$ were typical of the B type. In addition, the relative crystallinity, gelatinization temperature, and enthalpy, as determined via DSC thermogram, were highest in the vinegared sample and lowest in the blanched sample. In the amylogram results, the vinegared sample had the highest maximum viscosity and breakdown. The retrogradation of the vinegared sample was the slowest as its setback value was the lowest.

Air-side Heat Transfer and Friction Characteristics of Fined-tube Heat Exchangers under Heating Condition (핀-관 열교환기의 난방운전 시 공기측 열전달 및 마찰특성)

  • Kwon, Young Chul;Chang, Keun Sun;Ko, Kuk Won;Kim, Young Jae;Park, Byung Kwon
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.476-482
    • /
    • 2006
  • An experimental study has been performed to investigate the characteristics of air-side heat transfer and friction of a fined tube heat exchanger under heating conditions. Air enthalpy calorimeter was used to obtain the performance evaluation and analysis of the fined tube heat exchanger. Eight finned tube heat exchangers with slit fin, louver fin, and plain fin were used. The air-side heat transfer coefficient was calculated by the log-mean-temperature-difference. Air-side heat transfer and friction were presented in terms of j factor and friction factor on Reynolds number. From the experimental result, it was found that the variations of air-side heat transfer and friction of fined tube heat exchanger with the change of the fin configuration, row number, fin pitch, and tube circuit were obtained. j factor and friction factor decreased with Reynolds number increased. The tube circuit affected the air-side heat transfer and friction. In the case of slit and louver fin, j factor of 1st row was higher than that of 2nd row. But, with increasing Re, j factor was reversed. The characteristics of j factor and friction factor of 2nd row heat exchanger were different according to the kind of fins.