Boryeong Jeong;Seong Ho Park;Byong Duk Ye;Jihun Kim;Suk-Kyun Yang
Korean Journal of Radiology
/
v.24
no.4
/
pp.305-312
/
2023
Objective: Chronic enteropathy associated with SLCO2A1 gene (CEAS) is a recently recognized disease. We aimed to evaluate the enterographic findings of CEAS. Materials and Methods: Altogether, 14 patients with CEAS were confirmed based on known SLCO2A1 mutations. They were registered in a multicenter Korean registry between July 2018 and July 2021. Nine of the patients (37.2 ± 13 years; all female) who underwent surgery-naïve-state computed tomography enterography (CTE) or magnetic resonance enterography (MRE) were identified. Two experienced radiologists reviewed 25 and 2 sets of CTE and MRE examinations, respectively, regarding the small bowel findings. Results: In initial evaluation, eight patients showed a total of 37 areas with mural abnormalities in the ileum on CTE, including 1-4 segments in six and > 10 segments in two patients. One patient showed unremarkable CTE. The involved segments were 10-85 mm (median, 20 mm) in length, 3-14 mm (median, 7 mm) in mural thickness, circumferential in 86.5% (32/37), and showed stratified enhancement in the enteric and portal phases in 91.9% (34/37) and 81.8% (9/11), respectively. Perienteric infiltration and prominent vasa recta were noted in 2.7% (1/37) and 13.5% (5/37), respectively. Bowel strictures were identified in six patients (66.7%), with a maximum upstream diameter of 31-48 mm. Two patients underwent surgery for strictures immediately after the initial enterography. Follow-up CTE and MRE in the remaining patients showed minimal-to-mild changes in the extent and thickness of the mural involvement for 17-138 months (median, 47.5 months) after initial enterography. Two patients required surgery for bowel stricture at 19 and 38 months of follow-up, respectively. Conclusion: CEAS of the small bowel typically manifested on enterography in varying numbers and lengths of abnormal ileal segments that showed circumferential mural thickening with layered enhancement without perienteric abnormalities. The lesions caused bowel strictures that required surgery in some patients.
Jiyeon Ha;Seong Ho Park;Jung Hee Son;Ji Hun Kang;Byong Duk Ye;So Hyun Park;Bohyun Kim;Sang Hyun Choi;Sang Hyoung Park;Suk-Kyun Yang
Korean Journal of Radiology
/
v.23
no.1
/
pp.30-41
/
2022
Objective: Computed tomography enterography (CTE) and magnetic resonance enterography (MRE) are considered substitutes for each other for evaluating Crohn's disease (CD). However, the adequacy of mixing them for routine periodic follow-up for CD has not been established. This study aimed to compare MRE alone with the mixed use of CTE and MRE for the periodic follow-up of small bowel inflammation in patients with CD. Materials and Methods: We retrospectively compared two non-randomized groups, each comprising 96 patients with CD. One group underwent CTE and MRE (MRE followed by CTE or vice versa) for the follow-up of CD (interval, 13-27 months [median, 22 months]), and the other group underwent MRE alone (interval, 15-26 months [median, 21 months]). However, these two groups were similar in clinical characteristics. Three independent readers from three different institutions determined whether inflammation had decreased, remained unchanged, or increased within the entire small bowel and the terminal ileum based on sequential enterography of the patients after appropriate blinding. We compared the two groups for inter-reader agreement and accuracy (terminal ileum only) using endoscopy as the reference standard for enterographic interpretation. Results: The inter-reader agreement was greater in the MRE alone group for the entire small bowel (intraclass correlation coefficient [ICC]: 0.683 vs. 0.473; p = 0.005) and the terminal ileum (ICC: 0.656 vs. 0.490; p = 0.030). The interpretation accuracy was higher in the MRE alone group without statistical significance (70.9%-74.5% vs. 57.9%-64.9% in individual readers; adjusted odds ratio = 3.21; p = 0.077). Conclusion: The mixed use of CTE and MRE was inferior to MRE alone in terms of inter-reader reliability and could probably be less accurate than MRE alone for routine monitoring of small bowel inflammation in patients with CD. Therefore, the consistent use of MRE is favored for this purpose.
The purpose of this study is to evaluate an effectiveness of switching turbo direction to improve motion artifacts of small bowels and aorta. From June to October 2015, 60 patients suspected of having Crohn's disease were enrolled. The MR Enterography scans were performed using same protocol other than the turbo direction: with the Z phase encoding (group A) and with Y phase encoding (group B). Qualitative analysis of each group was performed to evaluate the effectiveness of switching turbo direction from Z to Y. As a result, the 5-point Likert scale for paired observers were $2.33{\pm}0.88$ for group A and $3.80{\pm}0.85$ for group B on dynamic contrast enhanced coronal images. In conclusion, group B is proved to be superior to group A and can lessen the motion artifacts derived from phase shifts.
Crohn's disease is a chronic idiopathic inflammatory disease of the intestines characterized by frequent relapse and remission. It often develops in children and adolescents, who are vulnerable to repeated exposure to ionizing radiations. Magnetic resonance enterography (MRE) is an increasingly important radiation-free imaging modality that is used to evaluate pediatric patients with Crohn's disease. MRE can evaluate extraluminal and extraintestinal abnormalities as well as the status of the bowel wall. In addition, MRE has an advantage in the evaluation of the small bowel involvement. MRE can be used for the initial diagnosis of Crohn's disease, and can aid in the assessment of disease activity and complications such as penetrating and fibrostenotic diseases. The aims of this article are to review the MRE technique for obtaining diagnostic and high-quality images and to discuss interpretations of imaging findings in patients with Crohn's disease.
Although small bowel the mainly occupies the most part of the gastrointestinal tract, small intestine tumors are rare, insidious in clinical presentation, and frequently represent a diagnostic and management challenge. Small bowel tumors are generally classified as epithelial, mesenchymal, lymphoproliferative, or metastatic. Familial adenomatous polyposis and Peutz-Jeghers syndrome are the most common inherited intestinal polyposis syndromes. Until the advent of capsule endoscopy (CE) and device-assisted enteroscopy (DAE) coupled with the advances in radiology, physicians had limited diagnostic examination for small bowel examination. CE and new radiologic imaging techniques have made it easier to detect small bowel tumors. DAE allows more diagnosis and deeper reach in small intestine. CT enteroclysis/CT enterography (CTE) provides information about adjacent organs as well as pictures of the intestinal lumen side. Compared to CTE, Magnetic resonance enteroclysis/enterography provides the advantage of soft tissue contrast and multiplane imaging without radiation exposure. Treatment and prognosis are tailored to each histological subtype of tumors.
Dong Wook Kim;Seong Ho Park;Jong Seok Lee;Hyun Jin Kim;Ah Young Kim;Byong Duk Ye;Suk-Kyun Yang
Korean Journal of Radiology
/
v.22
no.10
/
pp.1640-1649
/
2021
Objective: Flattening in the anteroposterior direction (AP flattening) of the terminal ileum (TI) or sigmoid colon (SC) lying across the psoas muscle, on magnetic resonance enterography (MRE), might mimic bowel inflammation in the coronal view. This study investigated the prevalence of AP flattening and the factors associated with its development. Materials and Methods: A total of 364 surgery-naïve patients with Crohn's disease (CD) who had undergone MRE were retrospectively reviewed. AP flattening was defined as a luminal collapse in the anteroposterior direction, with a bowel width in the axial plane < 1/4 of the normal diameter without reduction of bowel width in coronal images. The prevalence of AP flattening of the TI and SC on MRE in patients with bowel segments lying across the psoas muscle was determined. We further compared the rate of AP flattening between MRE and computed tomography enterography (CTE) in a subcohort of patients with prior CTE. The factors associated with AP flattening were analyzed using multivariable logistic regression in a subcohort of patients with endoscopic findings of TI. Results: Three hundred and twenty-two and 363 patients, respectively, had TI and SC lying across the psoas muscle. The prevalence of AP flattening on MRE was 7.5% (24/322) in TI and 5.2% (19/363) in SC. The prevalences were significantly higher on MRE than on CTE in both the TI (7.3% [12/164] vs. 0.6% [1/164]; p = 0.003) and SC (5.8% [11/190] vs. 1.6% [3/190]; p = 0.039). AP flattening of the TI was independently and strongly associated with the absence of CD inflammation on endoscopy, with an adjusted odds ratio of 0.066 (p = 0.003) for the presence versus the absence (reference) of inflammation. Conclusion: AP flattening of the TI or SC lying across the psoas muscle was uncommon and predominantly observed on MRE of the bowel without CD inflammation.
Kim, Yeon Soo;Kim, Se Hyung;Ryu, Hwa Sung;Han, Joon Koo
Korean Journal of Radiology
/
v.19
no.6
/
pp.1077-1088
/
2018
Objective: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. Materials and Methods: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. Results: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. Conclusion: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD.
Purpose To assess the quality of four images obtained using single-breath-hold (SBH), single-shot fast spin-echo (SSFSE) and multiple-breath-hold (MBH) SSFSE with and without deep-learning based reconstruction (DLR) in patients with Crohn's disease. Materials and Methods This study included 61 patients who underwent MR enterography (MRE) for Crohn's disease. The following images were compared: SBH-SSFSE with (SBH-DLR) and without (SBH-conventional reconstruction [CR]) DLR and MBH-SSFSE with (MBH-DLR) and without (MBH-CR) DLR. Two radiologists independently reviewed the overall image quality, artifacts, sharpness, and motion-related signal loss using a 5-point scale. Three inflammatory parameters were evaluated in the ileum, the terminal ileum, and the colon. Moreover, the presence of a spatial misalignment was evaluated. Signal-to-noise ratio (SNR) was calculated at two locations for each sequence. Results DLR significantly improved the image quality, artifacts, and sharpness of the SBH images. No significant differences in scores between MBH-CR and SBH-DLR were detected. SBH-DLR had the highest SNR (p < 0.001). The inter-reader agreement for inflammatory parameters was good to excellent (κ = 0.76-0.95) and the inter-sequence agreement was nearly perfect (κ = 0.92-0.94). Misalignment artifacts were observed more frequently in the MBH images than in the SBH images (p < 0.001). Conclusion SBH-DLR demonstrated equivalent quality and performance compared to MBH-CR. Furthermore, it can be acquired in less than half the time, without multiple BHs and reduce slice misalignments.
Objective: To investigate the diagnostic yield of contrast-enhanced computed tomography (CT) in Crohn's disease (CD) patients presenting with acute severe lower gastrointestinal bleeding (LGIB), and the role of CT in predicting the risk of rebleeding. Materials and Methods: A consecutive series of 110 CD patients presenting with acute severe LGIB between 2005 and 2016 were analyzed. Among them, 86 patients who had undergone contrast-enhanced CT constituted the study cohort. The diagnostic yield of CT for detecting contrast extravasation was obtained for the entire cohort and compared between different CT techniques. In a subgroup of 62 patients who had undergone CT enterography (CTE) and showed a negative result for extravasation on CTE, the association between various clinical and CTE parameters and the risk of rebleeding during subsequent follow-up was investigated using Cox regression analysis. Results: The diagnostic yield of CT was 10.5% (9 of 86 patients). The yield did not significantly differ between single-phase and multiphase examinations (p > 0.999), or between non-enterographic CT and CTE (p = 0.388). Extensive CD (adjusted hazard ratio [HR], 3.27; 95% confidence interval [CI], 1.09-9.80; p = 0.034) and bowel wall-to-artery enhancement ratio (adjusted HR, 2.81; 95% CI, 1.21-6.54; p = 0.016) were significantly independently associated with increased rebleeding risks, whereas anti-tumor necrosis factor-${\alpha}$ therapy after the bleeding independently decreased the risk of rebleeding (adjusted HR, 0.26; 95% CI, 0.07-0.95; p = 0.041). Conclusion: The diagnostic yield of contrast-enhanced CT was not high in CD patients presenting with acute severe LGIB. Nevertheless, even a negative CTE may be beneficial as it can help predict the risk of later rebleeding.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.