• Title/Summary/Keyword: Enophthalmos

Search Result 73, Processing Time 0.024 seconds

Endoscopic slide-in orbital wall reconstruction for isolated medial blowout fractures

  • Kim, Taewoon;Kim, Baek-Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.6
    • /
    • pp.345-350
    • /
    • 2020
  • Background: This study evaluated the efficacy of the endoscopic medial orbital wall repair by comparing it with the conventional transcaruncular method. This surgical approach differs from the established endoscopic technique in that we push the mesh inside the orbit rather than placing it over the defect. Methods: We retrospectively reviewed 40 patients with isolated medial orbital blowout fractures who underwent medial orbital wall reconstruction. Twenty-six patients underwent endoscopic repair, and 14 patients underwent external repair. All patients had preoperative computed tomography scans taken to determine the defect size. Pre- and postoperative exophthalmometry, operation time, the existence of diplopia, and pain were evaluated and compared between the two methods. We present a case showing our procedure. Results: The operation time was significantly shorter in the endoscopic group (44.7 minutes vs. 73.9 minutes, p= 0.035). The preoperative defect size, enophthalmos correction rate, and pain did not significantly differ between the two groups. All patients with preoperative diplopia, eyeball movement limitation, or enophthalmos had their symptoms resolved, except for one patient who had preexisting strabismus. Conclusion: This study demonstrates that endoscopic medial orbital wall repair is not inferior to the transcaruncular method. The endoscopic approach seems to reduce the operation time, probably because the dissection process is shorter, and no wound repair is needed. Compared to the previous endoscopic method, our method is not complicated, and is more physiological. Larger scale studies should be performed for validation.

Treatment of Blow-out Fractures Using Both Titanium Mesh Plate and Porous Polyethylene (Medpor®) (광범위한 안와파열골절에서 Titanium Mesh Plate와 Porous Polyethylene (Medpor®) 동시 사용의 유용성)

  • Gu, Ja Hea;Won, Chang Hoon;Dhong, Eun-Sang;Yoon, Eul-Sik
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.2
    • /
    • pp.85-90
    • /
    • 2010
  • Purpose: The goals of a blow-out fracture reconstruction are to restore the osseous continuity, provide support for the orbital contents and prevent functional and anatomic defects. Over the past several years, a range of autogenous and synthetic implants have been used extensively in orbital reconstructions. None of these implants have any absolute indications or contraindications in certain clinical settings. However, in extensive blow-out fractures, it is difficult to restore support of the orbital contents, which can cause more complications, such as enophthalmos. This study examined the clinical outcomes of extensive or comminuted blow-out fractures that were reconstructed by the simultaneous use of a titanium mesh plate and $Medpor^{(R)}$. Methods: Eighty six patients with extensive orbital fractures, who were admitted between March 1999 and February 2007, were reviewed retrospectively. The patients' chart and CT were inspected for review. Twenty three patients were operated on with both a titanium mesh plate (Matrix MIDFACE pre-formed orbital plate, Synthes, USA) and $Medpor^{(R)}$ (Porex, GA, USA). The patients underwent pre-operative CT scans to evaluate the fracture site and measure the area of the fracture. A transconjunctival approach was used, and titanium mesh plates were inserted subperiosteally with screw fixation. $Medpor^{(R)}$ was inserted above the titanium mesh plate. The patients were evaluated post-operatively for enophthalmos, diplopia, sensory disturbances and eyeball movement for a period of at least 6 months. Results: No implant-related complications were encountered during the follow-up period. Enophthalmos occurred in 1 patient, 1 patient had permanent sensory disturbance, and 3 patients complained of ocular pain and fatigue, which recovered without treatment. Although there were no significance differences between groups, the use of 2 implants had fewer complications. Therefore, it can be an alternative method for treating blow out fractures. Conclusion: The use of both a titanium mesh plate and $Medpor^{(R)}$ simultaneously may be a safe and acceptable technique in the reconstruction of extensive blow-out fractures.

Diplopia after inferior alveolar nerve block: case report and related physiology

  • You, Tae Min
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.2
    • /
    • pp.93-96
    • /
    • 2015
  • Although inferior alveolar nerve block is one of the most common procedures performed at dental clinics, complications or adverse effects can still occur. On rare occasions, ocular disturbances, such as diplopia, blurred vision, amaurosis, mydriasis, abnormal pupillary light reflex, retrobulbar pain, miosis, and enophthalmos, have also been reported after maxillary and mandibular anesthesia. Generally, these symptoms are temporary but they can be rather distressing to both patients and dental practitioners. Herein, we describe a case of diplopia caused by routine inferior alveolar nerve anesthesia, its related physiology, and management.

The Inferior Orbital Wall Reconstruction by Titanium Micro-mesh Remodeling (Titanium Micro-mesh의 개형을 통한 하벽부 안와골절의 재건)

  • Kim, Han Koo;Choi, Min Seok;Kim, Woo Seob;Bae, Tae Hui
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.81-85
    • /
    • 2009
  • Purpose: The inferior orbital wall is the most vulnerable to injury and inadequate reconstruction of inferior orbital fracture result in postoperative complications include enophthalmos, ocular dystopia and diplopia. Although the anatomical reconstruction of the inferior orbital wall is necessary to prevent these complications, the complexity of inferior orbital wall makes it difficult. We fabricated and remodeled the titanium micro-mesh plate for the anatomical reconstruction of inferior orbital wall. Methods: Twenty-nine patients with inferior orbital wall blow-out fracture were operated and twelve of them presented large extensive fracture. We intraoperatively fabricated and remodeled the Titanium-micro mesh to angulated lazy S shape similar to contralateral uninjured orbit. The preoperative and postoperative facial CT scan verified the 3-dimensional and anatomical reconstruction of the fractures. The mean follow-up was 19.7 months and postoperative complications was evaluated. Results: All cases showed the exact anatomical reconstruction, but there were minor complications in two cases. one patient had postoperative diplopia until 3months after surgery and the other patient had persistent enophthalmos (2 mm), but no further surgical correction was required. Conclusion: The comprehensive understanding of orbital convexity is the most important factor for anatomical reconstruction of inferior orbital fracture. We could prevent postoperative complications after inferior orbital wall reconstruction by intraoperative fabrication and anatomical remodeling of Titanium micro-mesh.

Orbital Wall Reconstruction by Copying a Template (defect model) from the Facial CT in Blow-out Fracture (얼굴뼈 CT 계측 모형을 이용한 안와벽골절의 재건)

  • Kim, Jae Keun;You, Sun Hye;Hwang, Kun;Hwang, Jin Hee
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.71-75
    • /
    • 2009
  • Purpose: Recently, orbital wall fracture is common injuries in the face. Facial CT is essential for the accurate diagnosis and appropriate treatment to reconstruct of the orbital wall. The objective of this study was to report the method for accurate measurement of area and shape of the bony defect in the blow-out fractures using facial CT in prior to surgery. Methods: The authors experienced 46 cases of orbital wall fractures and examined for diplopia, sensory disturbance in the area of distribution of the infraorbital nerve, and enophthalmos in the preoperation and followed 1 months after surgery, from August 2007 to May 2008. Bony defect was predicted by measuring continuous defect size from 3 mm interval facial CT. Copying from the defect model (template), we reconstructed orbital wall with resorbable sheet (Inion $CPS^{(R)}$ Inion Oy, Tampere, Finland). Results: One months after surgery using this method, 26 (100%) of the 26 patients improved in the diplopia and sensory disturbance in the area of distribution of the infraorbital nerve. Also 8 (72.7%) of the 11 patients had enophthalmos took favorable turn. Conclusion: This accurate and time-saving method is practicable for determining the location, shape and size of the bony defect. Using this method, we can reconstruct orbital wall fracture fastly and precisely.

Orbital Floor Reconstruction through Endoscopic Transnasal Approach Alone (안와하벽 파열 골절에 대한 내시경적 접근법만을 이용한 재건술)

  • Bae, Seong Hwan;Kang, Kyung Dong;Nam, Su Bong;Bae, Yong Chan;Choi, Soo Jong
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.99-103
    • /
    • 2012
  • Purpose: Many surgical methods for reconstruction of orbital floor fracture have been reported, which include subciliary approach, transconjunctival approach, transantral and transnasal endoscopic approach, etc. The purpose of this study is to demonstrate a surgical technique and analyze the results of transnasal endoscopic approach with Foley catheter ballooning without implantation of artificial surgical material through subciliary approach. Methods: Between February 2007 and November 2010, 29 orbital floor fracture patients, who had no herniated muscles through bone fragments, were treated through transnasal endoscopic approach with Foley catheter ballooning. Under the endoscopic view, the operator identified the opening of maxillary sinus. After widening of the opening using forceps, the operator reduced the fragmented bone with curved suction tip. Thereafter, 18-Fr Foley catheter was inserted. Four weeks after the operation, the catheter was removed. Results: Preoperatively, 6 patients had diplopias, 4 patients had limitations of extraocular motions and 3 patients had enophthalmos. After removal of the Foley catheter 4 weeks after the operation, 2 patients had diplopias, 1 patient had a limitation of extraocular motion, 1 patient has an enophthalmos and 1 patient had numbness on the cheek. These symptoms were resolved about 6 months after the surgery. Conclusion: The operative technique of Foley catheter ballooning through transnasal endoscopic approach without implantation of the artificial surgical material through subciliary approach can be considered one of the appropriate techniques for orbital floor fracture.

Anatomical Reconstruction of the Medial Orbital Wall Fracture (안와내벽골절의 해부학적 복원술)

  • Choi, Woo Kyung;Kang, Dong Hee;Oh, Sang Ah
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: In surgical treatment of the medial orbital wall fractures, restoring the original position of the orbital wall is difficult in some cases. Under such condition, the orbital wall is often reconstructed with synthetic material, without bony reduction, which is considered to be the conventional reconstruction. The purpose of this study is to compare the outcomes of anatomical reconstruction, which restores the bony wall to the anatomical position, from that of the conventional reduction in the isolated medial orbital wall fractures. Methods: Thirty patients, who underwent reconstruction surgery for the isolated medial orbital wall fractures from March 2007 to August 2011, were reviewed retrospectively. The surgical outcomes of two groups, the conventional reconstruction group (15 patients) and the anatomical reconstruction group (15 patients), were studied in 2 measurements, a one day before and 6 months after the surgery. The changes of orbital volume were calculated by the images from a computed tomography scan and enophthalmos was measured by a Hertel exophthalmometer. Results: The orbital volume ratio was decreased by an average of 1.05% in the conventional reconstruction group, while in the anatomical reconstruction group, the ratio decreased by 5.90% (p<0.05). The changes in the Hertel scale were 0.20 mm in the conventional reconstruction group, and 0.70 mm in the anatomical reconstruction group. However, the difference in the Hertel scale was statistically insignificant (p>0.05). Conclusion: In conclusion, the anatomical reconstruction technique of the isolated medial orbital wall fracture results in a better outcome than that of the conventional reconstruction, in terms of restoring of the original orbital volume and anatomic position. Thus, it can be considered as a useful method for the isolated medial orbital wall fractures.

Orbital wall restoration with primary bone fragments in complex orbital fractures

  • Jong Hyun Park;Dong Hee Kang;Hong Bae Jeon;Hyonsurk Kim
    • Archives of Craniofacial Surgery
    • /
    • v.24 no.2
    • /
    • pp.52-58
    • /
    • 2023
  • Background: Complex orbital fractures are impure orbital fractures because they involve the orbital walls and mid-facial bones. The author reported an orbital wall restoration technique in which the primary orbital wall fragments were restored to their prior position in complex orbital fractures in 2020. As a follow-up to a previous preliminary study, this study retrospectively reviewed the surgical results of complex orbital wall fractures over a 4-year period and compared the surgical outcomes by dividing them into groups with and without balloon restoration. Methods: Data of 939 patients with facial bone fractures between August 2018 and August 2022 were reviewed. Of these, 154 had complex orbital fractures. Among them, 44 and 110 underwent reduction with and without the balloon technique respectively. Pre- and postoperative Naugle exophthalmometer (Good-Lite Co.) scales were evaluated. The orbital volume and orbital volume ratio were calculated from preoperative and 6 months postoperative computed tomography images. Results: Among 154 patients with complex orbital fractures, 44 patients underwent restoration with the balloon technique, and 110 patients underwent restoration without it. The Naugle scale did not differ significantly between the two groups, but the orbital volume ratio significantly decreased by 3.32% and 2.39% in groups with and without the balloon technique and the difference in OVR was significantly greater in patients in the balloon restoration group compared with the control group. Postoperative balloon rupture occurred in six out of 44 cases (13.64%). None of the six patients with balloon rupture showed significant enophthalmos at 6 months of follow-up. Conclusion: The balloon rupture rate was 13.64% (6/44 cases) with marginal screw fixation, blunt screws, and extra protection with a resorbable foam dressing. Furthermore, we restored the orbital wall with primary orbital fragments using balloon support in complex orbital wall fractures.

THE TRANSCARUNCULAR APPROACH OF THE MEDIAL ORBITAL WALL FRACTURE (내측 안와벽 골절 처치: Transcaruncular approach)

  • Kim, Hyun-Chul;Choi, Ju-Seok;Baek, Jin-A;Shin, Hyo-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.1
    • /
    • pp.63-70
    • /
    • 2007
  • The occurrence of medial orbital wall fracture is isolated or combined with other facial bone fracture. There are many complications, for example, diplopia, enophthalmos, limitation of eye movement, visual activity depression and blindness. Because of these complications, the accurate diagnosis and treatment of medial orbital wall fracture is very important. We have reconstructed medial orbital walls with transcaruncular approach and obtained good results in patients with medial orbital wall fracture.

Bilateral Upper Eyelid Entropion in a HanWoo (Bos taurus coreanae) Calf

  • Jung, Sunjun;Kim, Jury;Lee, Dong-bin;Kim, Namsoo;Heo, Suyoung
    • Journal of Veterinary Clinics
    • /
    • v.36 no.5
    • /
    • pp.289-291
    • /
    • 2019
  • An 18-day-old male HanWoo calf was presented to the Animal Medical Center of Jeonbuk National University with a history of bilateral blepharospasm and epiphora. The calf was infected with rotavirus and was severly dehydrated. On ophthalmic examination, enophthalmos was noticed and the calf was diagnosed with bilateral upper eyelid entropion and resultant trichiasis. As a treatment, skin staples were applied, and the entropion was successfully corrected. Further, entropion has not recurred through the follow-up period.