• 제목/요약/키워드: Enhancement Ratio of Heat Transfer

검색결과 77건 처리시간 0.029초

A Study on the Heat Transfer Enhancement of Miniature loop Heat Pipes by Using the Cu Nanofluids

  • Kim, Young-Sik;Jeong, Hyo-Min;Chung, Han-Shik;Tanshen, Md.Riyad;Lee, Dae-Chul;Ji, Myoung-Kuk;Bae, Kang-Youl
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.70-77
    • /
    • 2013
  • An experimental study was carried out to understand the heat transfer performance of a miniature loop heat pipes using water-based copper nanoparticles suspensions as the working fluid. The suspensions consisted of deionized water and copper nanoparticles with an average diameter of 80 nm. Effects of the cupper mass concentration and the operation pressure on the average evaporation and condensation heat transfer coefficients, the critical heat flux and the total heat resistance of the mLHPs were investigated and discussed. The pressure frequency also depends upon the evaporator temperature which has been maintained from $60^{\circ}C$ to $90^{\circ}C$. The Investigation shows 60% filling ratio gives the highest inside pressure magnitude of highest number pressure frequency at any of setting of evaporator temperature and 5wt% results the lowest heat flow resistance.

평활관 및 열전달촉진관에서 액체질소의 관내 증발열전달 특성에 대한 연구 (Evaporation Heat Transfer Characteristics of Liquid Nitrogen in Horizontal Plain Tubes with Wire Coil Inserts)

  • 황지상;정진택;윤린;김용찬;문영준;김동혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1359-1364
    • /
    • 2004
  • An experiment was performed to study the evaporation heat transfer and the pressure drop characteristics of liquid nitrogen in a horizontal stainless steel tube with wire coil inserts. The inner diameter of test tube is 4.3mm and the length is 1.5m. Four wire coils having different pitch and thickness were inserted into the plain test tube. The wire coil length is 1.5m and the diameter is 3.65mm with thickness of 0.5mm and 0.9mm. Experiments were conducted at saturation temperature of $-191^{\circ}C$ mass flux from 200 to 370 $kg/m^{2}s$ and heat flux of 62 $kW/m^{2}$. Direct heating method was used to apply heat to the test section. Boiling heat transfer coefficients of both the plain and the enhanced tubes were calculated. Pressure drops between inlet and outlet side of test section were also measured, and they are used to estimate EPR(Enhancement Performance Ratio).

  • PDF

나선 그루브형 열사이폰의 작동유체의 변화에 대한 응축열전달 성능에 관한 연구 (A Study on the Performance of Condensation Heat Transfer for Various Working Fluid of Two-Phase Closed Thermosyphons with Various Helical Grooves)

  • 한규일;조동현
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.116-122
    • /
    • 2005
  • This study concerns the performance of condensing heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the type of working fluids are very important factors for the operation of thermosyphons. And the maximum enhancement (i.e. the ratio of the heat transfer coefficients the helical thermosyphons to plain thermosyphons) is $1.5{\sim}2$ for condensation.

나선 그루브형 열사이폰의 작동유체의 변화에 대한 응축열전달 성능에 관한 연구 (A Study on the Performance of Condensation Heat Transfer for Various Working Fluid of Two-Phase Closed Thermosyphons with Various Helical Grooves)

  • 한규일;조동현;박종운;이상진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.239-244
    • /
    • 2003
  • This study concerns the performance of condensing heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the type of working fluids are very important factors for the operation of thermosyphons. And the maximum enhancement (i.e. the ratio of the heat transfer coefficients the helical thermosyphons to plain thermosyphons) is $1.5{\sim}2$ for condensation.

  • PDF

발포금속의 열전달 특성에 관한 실험적 연구 (Study on the Heat Transfer Characteristic of Metallic Foam)

  • 김필환;김미화;김영진;정효민;정한식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.618-623
    • /
    • 2008
  • To enhancement heat transfer performance, the metallic foam as heat exchanger was studied rapidly. This was attributed to its high surface area to volume ratio as well as intensive flow mixing by tortuous flow passages. So the experimental study about the heat transfer characteristic of metallic foam is presented in this paper. The material in this experiment was used as FeCrAl which has density of 10 ppi, 20 ppi and 30 ppi respectively. And the results show the heat transfer is rise with permeability Reynolds number increase and the pressure drop metallic foam was increased with the ppi increase.

  • PDF

봉다발 유동 내 비틀림 혼합날개 지지격자의 대류열전달 성능 평가 (Evaluation of Convective Heat Transfer Performance of Twist-Vane Spacer Grid in Rod Bundle Flow)

  • 이치영
    • 대한기계학회논문집B
    • /
    • 제40권3호
    • /
    • pp.157-164
    • /
    • 2016
  • 봉다발 유동에서 비틀림 혼합날개 지지격자의 대류열전달 성능을 실험적으로 평가하였다. 시험부는 $4{\times}4$ 정사각 배열의 봉다발로 제작하였고, 모의 봉다발에서 봉 중심 간 거리와 봉 외경의 비는 ~1.35이다. 대류열전달 성능 평가를 위해 혼합날개 지지격자 하류에서 봉 벽면 온도의 원주방향 및 축방향 분포를 측정하였다. 원주방향의 경우, 지지격자 하류에서 비틀림 혼합날개 끝이 향하는 벽면의 온도가 가장 낮게 나타났는데 이는 비틀림 혼합날개에 의해 왜곡된 유동 때문으로 판단된다. 반면, 축방향의 경우, 혼합날개 지지격자 근처에서 벽면의 온도가 크게 낮아졌는데, 이는 비틀림 혼합날개에 의해 대류열전달이 향상됨을 의미한다. 비틀림 혼합날개 지지격자에 의해 대류열전달 성능은 지지격자 상류에 비해 지지격자 근처 하류에서 ~35 % 향상되었고, 실험데이터를 기반으로 비틀림 혼합날개 지지격자에 대한 열전달 성능 예측 상관식을 제안하였다.

Comparisons of 2-D and 3-D IVR experiments for oxide layer in the three-layer configuration

  • Bae, Ji-Won;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • 제52권11호
    • /
    • pp.2499-2510
    • /
    • 2020
  • We performed 3-D (3-dimensional) IVR (In-Vessel Retention) natural convection experiments simulating the oxide layer in the three-layer configuration, varying the aspect ratio (H/R). Mass transfer experiment was conducted based on the analogy to achieve high RaH's of 1.99 × 1012-6.90 × 1013 with compact facilities. Comparisons with 2-D (2-dimensional) experiments revealed different local heat transfer characteristics on upper and lower boundaries of the oxide layer depending on the H/R. For the 3-D shallow oxide layer, the multi-cell flow patterns appeared and the number of cells was considerably increased with the H/R decreases, which differs with the 2-D experiments that the number of cells was independent on H/R. Thus, the enhancement of the downward heat transfer and the mitigation of the focusing effect were more noticeable in the 3-D experiments.

수직 흡수전열관의 흡수성능에 미치는 스프링의 영향 (Influence of Spring on The Absorption Performance of a Vertical Absorber Tube)

  • 김정국;조금남
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.825-832
    • /
    • 2002
  • The present study investigated the enhancement of the absorption performance by the spring wrapped around the outer surface of the vertical falling film absorber tube. Heat and mass transfer enhancements were experimentally investigated, and flow visualization was performed to observe the wettability and flow pattern of the solution. The key experimental parameters were spring diameter (0.5, 1.0 mm) and spring pitch (1, 3, 10 mm), film Reynolds number (50~150), and concentration of LiBr-$H_2O$ solution (55, 60, 65 wt%). As the spring diameter was increased, the absorption mass flux, Sherwood number, Nusselt number, heat flux, and heat transfer coefficient were increased The Nusselt and Sherwood numbers showed the maximum at the spring pitch of 3mm, and the ratio of pitch to diameter of approximately 3 and 6 for the spring diamter of 0.5 mm, respectively.

배플과 관군간의 적정 누설유동을 이용한 쉘-관 열교환기의 성능향상 (Enhancement of Performance of Shell and Tube Heat Exchanger Using Pertinent Leakage Flow Between Baffle and Tube Bundles)

  • ;이근식
    • 대한기계학회논문집B
    • /
    • 제39권3호
    • /
    • pp.223-229
    • /
    • 2015
  • 배플과 관군간의 누설유동이 쉘-관 열교환기 성능에 미치는 영향을 FLUENT 를 사용하여 조사하였다. 쉘측 출구온도를 최대로 하는 최적누설유동을 찾기 위해 쉘측 단면적에 대한 누설단면적 비가 0%-40% 범위의 5 가지 누설유동을 가진 쉘-관 열교환기에 대하여 CFD 모델이 개발되었다. 관 입구 및 벽면온도를 일정하게 유지하고 Reynolds 수를 4952 부터 14858 증가시키면서 유동장 및 온도장을 계산하였다. 해석결과, 출구온도, 압력강하, 열전달률은 Reynolds 수뿐만 아니라 누설유동에도 크게 영향을 받는 것으로 나타났다. 누설유동은 열전달률과 압력강하를 동시에 낮추는 결과를 제시한 기존의 결과와는 달리, 본 연구에서는 적정의 누설유동은 배플 주위의 재순환영역에 추가적인 모멘텀을 공급함으로써 최대출구온도, 작은 압력강하, 높은 열전달률을 유도하는 효과를 발휘하는 새로운 결과를 얻었다. 20%의 누설단면적이 최적의 누설단면적으로 나타났다.

낮은 핀관과 Turbo-C 촉진관에서 R245fa의 외부 응축 열전달계수 (External Condensation Heat Transfer Coefficients of R245fa on Low Fin and Turbo-C Tubes)

  • 심윤보;박기정;정동수
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.167-175
    • /
    • 2009
  • In this study, condensation heat transfer coefficients(HTCs) of R22, R123, R134a and R245fa are measured on both 26fpi low fin and Turbo-C tubes. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling of $3{\sim}8^{\circ}C$. Test results show that HTCs of the newly developed low vapor pressure alternative refrigerant, R245fa, are $7.8{\sim}9.2%$ and $10.3{\sim}18.6%$ higher than those of R123 for 26fpi low fin tube and Turbo-C tube respectively. For all refrigerants tested, HTCs of Turbo-C enhanced tube are higher than those of 26fpi low fin tube. For the low fin tube, Beatty and Katz's prediction equation yielded 20% deviation for all fluids. The heat transfer enhancement ratio of R245fa on the Turbo-C tube is $5.9{\sim}6.4$ while that of R123 is $5.7{\sim}5.9$. From the view point of environmental safety and condensation heat transfer, R245fa is a long term candidate to replace R123 currently used in centrifugal chillers.