• 제목/요약/키워드: Enhanced output torque

검색결과 10건 처리시간 0.03초

교류 전동기의 출력 토크 향상을 위한 인버터의 과변조 성능 개선 방법 (Method for Improving Overmodulation Performance of an Inverter for the Enhanced Output Torque of AC Motors)

  • 정혜인;김상훈
    • 전력전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.273-278
    • /
    • 2019
  • This study proposes a method for improving the overmodulation performance of a three-phase inverter to obtain an enhanced output torque for the AC motors. In the inverter-fed AC motor drives, the output torque of the motor can be enhanced by utilizing the overmodulation region as well as the linear modulation regions of the inverter. The overmodulation method is used for this overmodulation operation of the inverter. However, the voltage gain, the ratio of the output voltage of the inverter to the reference voltage achieved by the conventional overmodulation methods becomes nonlinearly smaller than unity. Therefore, the effect of improving the output torque of the AC motors is insignificant even when the overmodulation region is utilized. In this study, we propose a method that improves the overmodulation performance of the inverter by compensating the limited amount of the reference voltage in the overmodulation operation to enhance the output torque of the AC motors. The effectiveness of the proposed method is verified through the simulations and experiments with an 800 W permanent magnet synchronous motor.

구동 출력 토크 측정을 이용한 비틀림 진동 절연 성능 평가 (Evaluation of Torsional Vibration Isolation Performance Using In-situ Driveline Output Torque Measurement)

  • 김기우;장재덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.382-387
    • /
    • 2012
  • This paper presents a proof-of-concept study on the evaluation of torsional vibration isolation performance through in-situ output torque measurement by using a non-contacting magneto-elastic torque transducer installed in the vehicle driveline system. The de-trending processing is first conducted to extract the torsional vibration from the measured driveline output torque. In order to estimate the transmissibility, primary performance indicator of a vibration isolator, the magnitude of transmitted torsional vibration with different frequencies is compared. From the conservative estimation results, the torsional damper built in a lock-up clutch of a torque converter is identified to be a vibration isolator. The evaluation results show that the fluid damping by torque converter outperforms the vibration isolation function of a torsional damper, and the isolation performance needs to be enhanced.

  • PDF

토크 측정을 이용한 차량 변속기용 비틀림 진동 절연 댐퍼 평가 (Evaluation of Torsional Vibration Isolation Damper in Automotive Transmissions Based on In-situ Torque Measurement)

  • 김기우;장재덕
    • 한국소음진동공학회논문집
    • /
    • 제22권4호
    • /
    • pp.377-382
    • /
    • 2012
  • This paper presents a proof-of-concept study on the evaluation of torsional vibration isolation performance through in-situ output torque measurement by using a non-contacting magneto-elastic torque transducer installed in the vehicle driveline system. The de-trending processing is first conducted to extract the torsional vibration from the measured driveline output torque. In order to estimate the transmissibility, primary performance indicator of a vibration isolator, the magnitude of transmitted torsional vibration with different frequencies is compared. From the conservative estimation results, the torsional damper built in a lock-up clutch of a torque converter is identified to be a vibration isolator. The evaluation results show that the fluid damping by torque converter outperforms the vibration isolation function of a torsional damper, and the isolation performance needs to be enhanced.

Control Strategy of Total Output Power Ripple Cancellation for DFIG in MV Wind Power Systems under Unbalanced Grid Conditions

  • Han, Daesu;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.355-356
    • /
    • 2015
  • This paper proposes a control strategy of total output power ripple cancellation for both of Machine-Side Converter (MSC) and Grid-Side Converter (GSC) in a DFIG under unbalanced grid conditions. The proposed control strategy for the MSC is the zero torque ripple control algorithm with an enhanced LVRT capability. The control algorithm for the MSC exhibits reduced torque pulsation in steady-state unbalanced grid conditions. In addition, this control algorithm also minimizes a peak value of rotor current in transient unbalanced grid conditions. The total output power ripple cancellation control algorithm is adopted in the GSC. The total output power ripple cancellation is achieved by nullifying the oscillating component of the total output active and reactive power at the summing point of stator and rotor of DFIG. The proposed control strategy for the GSC reduces the output power oscillation leading to the improved quality of wind farms output.

  • PDF

토크 발생기의 신뢰성 향상 (Reliability Evaluation of Torque Generator)

  • 정동수;이용범;박종원
    • 동력기계공학회지
    • /
    • 제16권6호
    • /
    • pp.59-65
    • /
    • 2012
  • Torque Generator is a product which has function to transform hydraulic energy to mechanical energy of torque and rotating speed, and be used for direction change device of agricultural machines. This study proposes failure analysis and test analysis on torque generator and introduces a process that reliability of a product is enhanced by design improvement. And also it presents improvements of maximum output torque by modifying design and surface treatment. Lastly it verifies reliability improvement by analyzing test results of before and after life test.

Spoke Type 전동기 및 착자기 최적설계 (Optimum Shape Design of Spoke Type Motor and Magnetizer by Characteristic Analysis)

  • 김영현;이진경;서준;이중호
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.286-297
    • /
    • 2016
  • This study proposes criteria for both optimal-shape and magnetizer-system designs to be used for a high-output spoke-type motor. The study also examines methods of reducing high-cogging torque and torque ripple, to prevent noise and vibration. The optimal design of the stator and rotor can be enhanced using both a response surface method and finite element method. In addition, a magnetizer system is optimally designed for the magnetization of permanent magnets for use in the motor. Finally, this study verifies that the proposed motor can efficiently replace interior permanent magnet synchronous motor in many industries.

다상 BLDC 모터 드라이브 시스템의 개방 고장 시 효율 향상이 고려된 토크 리플 저감 대책 (Torque Ripple Reduction Method With Enhanced Efficiency of Multi-phase BLDC Motor Drive Systems Under Open Fault Conditions)

  • 김태윤;서용석;박현철
    • 전력전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.33-39
    • /
    • 2022
  • A multi-phase brushless direct current (BLDC) motor is widely used in large-capacity electric propulsion systems such as submarines and electric ships. In particular, in the field of military submarines, the polyphaser motor must suppress torque ripple in various failure situations to reduce noise and ensure stable operation for a long time. In this paper, we propose a polyphaser current control method that can improve efficiency and reduce torque ripple by minimizing the increase in stator winding loss at maximum output torque by controlling the phase angle and amplitude of the steady-state current during open circuit failure of the stator winding. The proposed control method controls the magnitude and phase angle of the healthy phase current, excluding the faulty phase, to compensate for the torque ripple that occurs in the case of a phase open failure of the motor. The magnitude and phase angle of the controlled steady-state current are calculated for each phase so that copper loss increase is minimized. The proposed control method was verified using hardware-in-the-loop simulation (HILS) of a 12-phase BLDC motor. HILS verification confirmed that the increase in the loss of the stator winding and the magnitude of the torque ripple decreased compared with the open phase fault of the motor.

토로이달 무단변속기 동적 거동에 관한 연구 (A Study on the Dynamic Behaviors of Toroidal Infinitely Variable Transmission)

  • 장시열;최완
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.348-354
    • /
    • 2003
  • An analysis of the dynamic behavior between disk and roller has been performed when the torque is transmitted to toroidal IVT (Infinitely Variable Transmission). The contact area, shape and pressure with elliptical shapes between disk and roller are computed as the transmission ratios are changed. This study will give the information of contact shapes between roller-input dist and roller-output disk which are working under the most severe condition. The computed results are expected to guide the design criteria for the enhanced endurance li(e. Furthermore, the investigation of contact behaviors is very crucial to develop the traction oil that the efficiency of IVT system is most dependent on.

  • PDF

Near-Five-Vector SVPWM Algorithm for Five-Phase Six-Leg Inverters under Unbalanced Load Conditions

  • Zheng, Ping;Wang, Pengfei;Sui, Yi;Tong, Chengde;Wu, Fan;Li, Tiecai
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.61-73
    • /
    • 2014
  • Multiphase machines are characterized by high power density, enhanced fault-tolerant capacity, and low torque pulsation. For a voltage source inverter supplied multiphase machine, the probability of load imbalances becomes greater and unwanted low-order stator voltage harmonics occur. This paper deals with the PWM control of multiphase inverters under unbalanced load conditions and it proposes a novel near-five-vector SVPWM algorithm based on the five-phase six-leg inverter. The proposed algorithm can output symmetrical phase voltages under unbalanced load conditions, which is not possible for the conventional SVPWM algorithms based on the five-phase five-leg inverters. The cause of extra harmonics in the phase voltages is analyzed, and an xy coordinate system orthogonal to the ${\alpha}{\beta}z$ coordinate system is introduced to eliminate low-order harmonics in the output phase voltages. Moreover, the digital implementation of the near-five-vector SVPWM algorithm is discussed, and the optimal approach with reduced complexity and low execution time is elaborated. A comparison of the proposed algorithm and other existing PWM algorithms is provided, and the pros and cons of the proposed algorithm are concluded. Simulation and experimental results are also given. It is shown that the proposed algorithm works well under unbalanced load conditions. However, its maximum modulation index is reduced by 5.15% in the linear modulation region, and its algorithm complexity and memory requirement increase. The basic principle in this paper can be easily extended to other inverters with different phase numbers.

건설기계의 배출가스 저감을 위한 대형 프로판 전용 엔진 개발 (Development of Large-sized Propane Engine for Emission Reduction of Construction Machinery)

  • 김용래;박철웅;장형준;최영;정문용;한명훈;정동훈
    • 한국가스학회지
    • /
    • 제27권3호
    • /
    • pp.91-97
    • /
    • 2023
  • 오래된 디젤 엔진을 탑재하고 있는 노후화된 건설용 기계 및 차량들은 보통 수명이 길기 때문에 최신의 배기 규제와는 동떨어진 수준의 유해한 배출가스를 계속 배출하고 있다. 따라서 이러한 구형 디젤 엔진을 최신 배기 규제를 만족하는 엔진으로 대체할 수 있다면 대기질 개선에 도움이 될 것으로 기대되는데, 건설 현장에서 손쉽게 구할 수 있는 프로판 연료를 적용한 엔진이 적합한 대안이 될 수 있다. 따라서 본 연구에서는 6.8리터 CNG 엔진을 베이스로 프로판 전용 엔진을 개발하였으며, 가스 전용 인젝터, 배기가스재순환(EGR), 강화된 촉매 등의 기술이 적용되었다. 그 결과 동급의 디젤 엔진 출력 및 토크를 확보하는 한편 최신 배출가스 규제인 Stage-V 수준에서 질소산화물은 절반 수준에 해당하는 배출가스 성능을 달성하였다.