딤플이 설치된 채널에서 레이놀즈 수 및 딤플 깊이에 따른 유동 및 열전달 특성 (Effects of Dimple Depth and Reynolds Number on the Flow and Heat Transfer in a Dimpled Channel)

  • 안준;이영옥;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3253-3258
    • /
    • 2007
  • A large eddy simulation (LES) has been conducted for the flow and heat transfer in a dimpled channel. Two dimple depths of 0.2 and 0.3 times of the dimple print diameter (= D) have been compared at the bulk Reynolds number of 20,000. Three Reynolds numbers of 5,000, 10,000 and 20,000 have been studied, while the dimple depth is kept as 0.2 D. With the deeper dimple, the flow reattachment occurs father downstream inside the dimple, so that the heat transfer is not as effectively enhanced as the case with shallow ones. At the low Reynolds number of 5,000, the Nusselt number ratio is as high as those for the higher Reynolds number, although the value of heat transfer coefficient decreases because of the weak shear layer vortices.

  • PDF

Study on Heat Transfer Characteristics according to Flowing Particles in a Cold Water Tube

  • Park, Ki-Won;Kim, Myoung-Jun;Jung, Sung-Chan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권3호
    • /
    • pp.243-251
    • /
    • 2007
  • This experiment was conducted to investigate the effect of particles on the heat transfer characteristics of fluids flowing in a cold water tube. Plastic beads with 3 different sizes were used as flowing particles with cold water. An experimental test section was composed of concentric double tubes having diameters of 25mm for the inner tube and 50mm for the outer tube. The materials for the inner and outer tubes are copper and PVC respectively. It was found that the particles enhanced the heat transfer coefficient by random and vortex motion in the fluid. Hence the heat transfer coefficients for the fluid with 2mm, 5mm and $2{\times}6mm$ particles were $7%{\sim}37%$ higher than the fluid without the particles.

대와류를 이용한 채널 내 열전달 증진 (Effective Heat Transfer Using Large Scale Vortices)

  • 윤동혁;최춘범;이경준;양경수
    • 대한기계학회논문집B
    • /
    • 제32권3호
    • /
    • pp.198-206
    • /
    • 2008
  • A numerical study has been carried out to investigate heat transfer enhancement in channel flow using large-scale vortices. A square cylinder, inclined with respect to the main flow direction, is located at the center of the channel flow, generating a separation region and Karman vortices. Two cases are considered; one with a fixed blockage ratio and the other one with a fixed cylinder size. In both cases, the flow characteristics downstream of the cylinder significantly change depending on the inclination angle. As a result, heat transfer from channel wall is significantly enhanced due to increased vertical-velocity fluctuations induced by the large-scale vortices shed from the cylinder. Quantitative results as well as qualitative physical explanation are presented to justify the effectiveness of the inclined square cylinder as a vortex generator to enhance heat transfer from channel wall.

수직원형관내 초임계압 물의 난류 열전달에 관한 직접수치모사 (Direct Numerical Simulation of Turbulent Heat Transfer to Water at Supercritical Pressure Flowing in Vertical Pipes)

  • 이상훈;배중헌;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2471-2476
    • /
    • 2008
  • Turbulent flow and heat transfer to water at supercritical pressure flowing in vertical pipes is investigated using direct numerical simulation (DNS). A conservative space-time discretization scheme for variable-density flows at low Mach numbers is adopted in the present study to treat steep variations of fluid properties at supercritical pressure just above the thermodynamic critical point. The fluid properties at these conditions are obtained using PROPATH and used in the form of tables in the simulations. The buoyancy influence induced by strong variation of density across the pseudo-critical temperature proved to play an important role in turbulent flow and heat transfer at supercritical state. Depending on the degree of buoyancy influence, turbulent heat transfer may be enhanced or significantly deteriorated, resulting in local hot spots along the heated surface.

  • PDF

Effects of included angle on pool boiling of tube array having horizontal upper tube

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.530-537
    • /
    • 2020
  • This study investigates the effect of an included angle and heat flux on heat transfer of V-shape tube array having a horizontal upper tube. The test uses two stainless steel tubes with a smooth surface submerged under the water at atmospheric pressure. The angle varies from 2° to 24°. The heat transfer coefficient gets decreasing in consequence as the angle increases. The enhancement due to the lower tube is distinct as the heat flux is lower than 60 kW/㎡, where the effect of the convective flow is dominant. The present study and the published results show a similar tendency. Although the heat transfer coefficient for the present study is smaller than the symmetry case, enhanced heat transfer is observed compared to the tube array having a lower horizontal tube as the included angle is less than 10°.

삼각형 멀티 탭을 이용한 충돌제트 열전달 향상 연구 (Enhancement of Impinging Jet Heat Transfer Using Triangular Multi-Tabs)

  • 이정욱;이상준
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1139-1146
    • /
    • 2004
  • The effect of triangular tabs attached at the perimeter of jet nozzle on heat transfer enhancement was investigated experimentally. The modified flow structure was visualized using a smoke-wire method. Four different types of jet nozzle having 0, 4, 6 and 8 tabs were tested at jet Reynolds number Re=15,000 to investigate the effect of tabs on the variation of heat transfer rate. The local and average Nusselt numbers are increased with increasing the number of tabs. At nozzle-to-plate distance of L/D=4, the average Nusselt number was increased about 9.9% at Re=15,000 in the impingement region for the case of 8 tabs attachment. As the nozzle-to-plate distance increases, however, the heat transfer enhancement effect of triangular tabs is reduced. For the case of 4 tabs, the heat transfer enhancement is not so distinctive at L/D=8. As the protrusion depth of tabs into the jet flow increases, the heat transfer rate is also enhanced when the nozzle-to-plate distance is smaller than L/D=6.

원주 후미에 부착된 와동발생기의 영각 변화에 따른 유동 및 열전달 특성 (Flow and Heat Transfer Characteristics due to the Variations of the Angle of Attack at the Vortex Generators located behind a Circular Cylinder)

  • 하홍영;홍철현;양장식;이기백
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.439-449
    • /
    • 2002
  • Experimental investigations of the flow structure and heat transfer enhancement in a channel with a built-in circular cylinder and a wing-let type vortex generator are presented. Without any vortex generators, relatively low heat transfer takes place in the downstream of the circular cylinder where is a recirculation region with low velocity fluid is formed. However with a wing-let type longitudinal vortex generator in the wake region behind the cylinder, heat transfer in the region can be enhanced. In order to control the strength of longitudinal vortices, the angle of attack of the vortex generators is varied from $20^{circ} to 45^{\circ}$, but spacings between the vortex generations are fixed to be 5 mm. The 3-dimensional mean velocity field downstream of the vortex generator is measured by a five-hole pressure probe, and the hue-capturing method using thermochromatic liquid crystals has been used to provide the local distribution of the heat transfer coefficient. The vorticity field and streamwise velocity contour are obtained from the velocity field. Streamwise distributions of averaged Stanton number on the measurement planes show very similar trends for all the experimental cases($\beta=20^{circ}, 30^{circ} and 45^{\circ}$). Circulation strength and heat transfer coefficient have the maximum values when the angle of attack($\beta$) is $30^{\circ}$.

Convective heat transfer of MWCNT / HT-B Oil nanofluid inside micro-fin helical tubes under uniform wall temperature condition

  • Kazemia, M.H.;Akhavan-Behabadi, M.A.;Nasr, M.
    • Advances in nano research
    • /
    • 제2권2호
    • /
    • pp.99-109
    • /
    • 2014
  • Experiments are performed to investigate the single-phase flow heat transfer augmentation of MWCNT/HT-B Oil in both smooth and micro-fin helical tubes with constant wall temperature. The tests in laminar regime were carried out in helical tubes with three curvature ratios of 2R/d=22.1, 26.3 and 30.4. Flow Reynolds number varied from 170 to 1800 resulting in laminar flow regime. The effect of some parameters such as the nanoparticles concentration, the dimensionless curvature radius (2R/d) and the Reynolds number on heat transfer was investigated for the laminar flow regime. The weight fraction of nanoparticles in base fluid was less than 0.4%. Within the applied range of Reynolds number, results indicated that for smooth helical tube the addition of nanoparticles to the base fluid enhanced heat transfer remarkably. However, compared to the smooth helical tube, the average heat transfer augmentation ratio for finned tube was small and about 17%. Also, by increasing the weight fraction of nanoparticles in micro-fin helical tubes, no substantial changes were observed in the rate of heat transfer enhancement.

응축용 특수 전열관의 열전달 특성에 관한 연구 (Experimental Study on Condensation Heat Transfer Characteristics of Special Heat Transfer Tubes)

  • 한규일;박종운;권영철;조동현
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.827-835
    • /
    • 2001
  • In this study, condensation heat transfer characteristics were conducted with special heat transfer tubes of SH-C type. Experiments were carried out the saturated vapor temperature of 334K and the wall subcooling of 1.5-4.5K. The refrigerant was R-113 and the enhanced tubes used in the present study were SH-CDR, SH-CYR and SH-CHR. The experimental results showed that the condensation heat transfer coefficients of SH-C type tubes were about 23-66% higher than those of a low integral-fin tube. It was visualized that the condensed liquid on the outer surface of SH-C type tubes flowed continuously down unlike a low integral-fin tube and a plain tube, due to a 3-D extending fin on the outer surface of SH-C type tubes. As a result, the thermal resistance of the condensed liquid decreased and the heat transfer coefficient increased. Also, the enhancement ratio of SH-CDR tube was the highest, and it was about 9-11 times as compared to that of a plain tube.

  • PDF

초음속 유동장내 2차분사 분사각도 변화에 따른 열전달 특성 변화 (Heat Transfer on Secondary Injection Surface in Supersonic Flow-field with Various Injection Angle)

  • 송지운;이종주;조형희;배주찬
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.321-325
    • /
    • 2008
  • 초음속 유동장내에 분사된 2차제트 주변에서의 열전달 현상을 고찰 하였다. 초음속 유동장내에 분사되는 2차유동의 Jet to freestream momentum ratio(운동량비)의 변화와, 2차유동 분사각도에 따른 2차 분사홀 주변의 열전달 특성을 파악하기 위하여 홀 주변의 표면온도 변화를 고속 적외선 카메라를 통하여 측정하였으며, 이를 이용하여 비정상 열유속 기법을 바탕으로 열유속을 계산하였다. 운동량비가 증가할 수록 열전달 현상이 강화 되었으며, $15^{\circ}$ 기울어진 분사보다는 수직 분사의 경우에 더 강한 열전달 현상이 발생되었다. 이를 통해 분사비와 분사 각도가 표면 열전달 분포에 중요한 요인으로 작용함을 확인할 수 있었다.

  • PDF