• 제목/요약/키워드: Enhanced

검색결과 22,896건 처리시간 0.046초

Focal nodular hyperplasia: Tripie-contrast enhanced MR imaging using gadolinium chelates, mangafodipir trisodium, and ferumoxides

  • Kim, Joo-Hee;Kim, Myeong-Jin;Park, Young-Nyun;Kim, Kyung-Sik;Lee, Jong-Tae;Yoon, Hyung-Sik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.140-140
    • /
    • 2001
  • We present two cases of surgically proven focal nodular hyperplasia whou underwent tri contrast-enhance MR imaging using gadolinium chelates, mangafodipir trisodium, and ferumoxides After the unehanced MR images were obtained, dynamic gadolinium-enhanced T1-weighted imagi were performed, then mangafodipir enhanced and ferumoxides-enhanced images were obtained. In one case, the mass was isointense on both T1- and T2-weighted images on the unehanced M images, iso and slightly hyperintense on ferumoxides-enhanced FSE and GRE images, strong hyperintense on the mangafodipir enhanced and gadolinium enhanced arterial phase images. In th other case, the mass was isointense on T2-weighted and hypointense on T1-weighted image isointense on ferumoxides-enhanced images, and hyperintense on mangafodipir enhanced an gadolinium enhanced arterial phase images. Triple contrast enhanced MR images were useful correctly diagnose these two cases preoperatively.

  • PDF

차세대 지상파 DTV 전송시스템을 위한 Enhanced-TCM CODEC 개발 (Enhanced-TCM CODEC Development for Next Generation Terrestrial DTV Transmission System)

  • 김성훈;지금란;이재영;김승원;이수인;김창중;이호경
    • 방송공학회논문지
    • /
    • 제10권1호
    • /
    • pp.14-21
    • /
    • 2005
  • 본 논문은 보행/이동수신 환경에서 기존의 ATSC(Advanced Television System Committee) 8-VSB DTV 전송규격의 수신성능을 개선한 Enhanced-xVSB를 제안한다. E-xVSB시스템은 normal(8-VSB) 스트림과 enhanced(robust) 스트림을 섞어 전송하며. robust 스트림은 기존의 8-VSB 스트림인 normal stream에 비해 모드에 따라 TOY(Threshold Of Visibility)를 만족하는 SNR을 획기적으로 개선시킬 수 있으며. 이와 같은 robust 스트림은 E-xVSB 전용수신기가 아닌 기존 수신기에서는 MPEG 스트림 역다중화 과정에서 누락되어지므로 기존의 8-VSB 수신기와 하위호환성을 유지한다. E-xVSB는 이동 및 보행수신 성능개선을 위해 reduced constellation 및 enhanced trellis coded modulation기법을 도입하였으며. 사용목적에 따라 Pseudo-2VSB. Enahnced-4VSB. Enhanced-xVSB 및 Hybrid 모드등 다양한 변조기법을 지원한다.

Generation of contrast enhanced computed tomography image using deep learning network

  • Woo, Sang-Keun
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권3호
    • /
    • pp.41-47
    • /
    • 2019
  • In this paper, we propose a application of conditional generative adversarial network (cGAN) for generation of contrast enhanced computed tomography (CT) image. Two types of CT data which were the enhanced and non-enhanced were used and applied by the histogram equalization for adjusting image intensities. In order to validate the generation of contrast enhanced CT data, the structural similarity index measurement (SSIM) was performed. Prepared generated contrast CT data were analyzed the statistical analysis using paired sample t-test. In order to apply the optimized algorithm for the lymph node cancer, they were calculated by short to long axis ratio (S/L) method. In the case of the model trained with CT data and their histogram equalized SSIM were $0.905{\pm}0.048$ and $0.908{\pm}0.047$. The tumor S/L of generated contrast enhanced CT data were validated similar to the ground truth when they were compared to scanned contrast enhanced CT data. It is expected that advantages of Generated contrast enhanced CT data based on deep learning are a cost-effective and less radiation exposure as well as further anatomical information with non-enhanced CT data.

Quality characteristics of the enhanced beef using winter mushroom juice

  • Choi, Yun-Sang;Jo, Kyung;Lee, Seonmin;Yong, Hae In;Jung, Samooel
    • Journal of Animal Science and Technology
    • /
    • 제62권3호
    • /
    • pp.396-408
    • /
    • 2020
  • This study investigated the quality properties of enhanced beef, manufactured by injecting the beef with a brine containing winter mushroom juice powder (WMJP). The enhanced beef was manufactured by injecting the eye of round with brine (15% by green weight). Four treatments consisted of control (no injection of brine) and three enhanced beef, EBS (brine containing 5 g sodium chloride per kg beef), EBW 0.2 (brine containing 5 g sodium chloride and 2 g WMJP per kg beef), and EBW 0.5 (brine containing 5 g sodium chloride and 5 g WMJP per kg beef), were tested. The effect of enhancement or WMJP on the quality properties of beef was evaluated during storage at 4℃ for 1, 5, and 10 days. Total aerobic bacteria counts between the control and the enhanced beef, and among EBS, EBW 0.2, and EBW 0.5 were not significantly different after any storage period (p > 0.05). The pH of beef was not different between the control and the enhanced beef, and among enhanced beef at 1 and 5 days of storage (p > 0.05). However, it was higher in the enhanced beef than control, and EBW 0.2 and EBW 0.5 had higher pH than EBS after 10 days of storage (p < 0.05). The enhanced beef showed a high total loss at all storage days (p < 0.05). There were no differences in total loss among enhanced beef after any storage period (p > 0.05). The enhanced beef had no consistent differences in L*, a*, and b* values with control during storage, however, EBW 0.5 showed high color stability. The hardness of the enhanced beef was significantly lower than that of the control after 10 days of storage, although the values were lower at all storage stages. EBS 0.5 had the lowest thiobarbituric acid reactive substance (TBARS) value among cooked beef of all treatments at all storage days. The enhanced beef received higher scores in all sensory properties than control, and no negative effect of WMJP was found in the sensory quality of the enhanced beef. The use of winter mushroom juice can result in quality improvement in enhanced beef.

차세대 지상파 DTV 전송방식 시스템을 위한 Enhanced-xVSB 개발 (Enhanced-xVSB Development for Next Generation Terrestrial DTV Transmission System)

  • 김성훈;지금란;이재영;김승원;이수인;김창중;이호경
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2004년도 정기총회 및 학술대회
    • /
    • pp.281-284
    • /
    • 2004
  • This paper described an Enhanced-xVSB system for improving mobile/pedestrian reception performance to the ATSC DTV 8-VSB transmission standard. E-xVSB system can transmit a mixture of normal (8-VSB) stream and enhanced (robust) stream. The robust stream has a higher threshold of visibility (TOV) compared to the standard stream, and legacy receivers ignore the robust packets. Thus, Enhanced-xVSB system is fully backward compatible with a current ATSC standard. for mobile and portable reception support, E-xVSB system adopts a reduced constellation method as well as enhanced trellis-coded modulation scheme. E-xVSB system supports a variety of enhanced modulation schemes: Pseudo-2VSB, Enhanced-4VSB, modified Enhanced-8VSB and Hybrid-VSB. Proposed E-xVSB system performs well under serious dynamic multipath reception environment.

  • PDF

차세대 지상파 DTV 전송시스템 개발 (Enhanced-x VSB System Development for Next Generation Terrestrial DTV RF Transmission)

  • 김성훈;이재영;이수인;안치득;김기두
    • 방송공학회논문지
    • /
    • 제12권2호
    • /
    • pp.120-127
    • /
    • 2007
  • 본 논문에서는 ATSC 8-VSB 전송방식과 하위호환성을 유지하며, 수신성능을 비약적으로 개선시킨 Enhanced-xVSB 1/4 rate robust modulation 방식을 제안한다. Enhanced-xVSB 1/4 rate 모드는 보행 및 이동수신을 위해 데이터 전송량 및 수신성능개선의 상호 trade-off를 방송사측에 폭넓게 제공한다. Enhanced-xVSB 1/4 rate mode는 AWGN 및 다양한 multipath fading환경에서의 VSB수신성능을 비약적으로 발전시켰으며, 본 논문에서는 Enhanced-x VSB 지상파 전송시스템을 보행, 이동수신을 위한 ATSC 차세대 전송방식으로 제안한다.

원심성형 고성능 RC 말뚝의 이음부 보강에 대한 해석적 연구 (A Numerical Study on Flexure Performance of Enhanced Spun RC Pile with Reinforced Joint)

  • 주상훈;황훈희;배재현;이지훈
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.70-77
    • /
    • 2018
  • In this study, the reinforced methods of joints were proposed to improve the structural performance of the enhanced spun reinforced concrete piles with joints. To verify the proposed methods, flexure performance was validated by finite element analysis considering both material and contact nonlinearity. Based on the previous study and those results of the analysis, it is concluded that the structural performance of the current joints system for the enhanced spun RC piles can be enhanced by applying the reinforced joints composed of extended circular band plates and studs. This proposed method showed the nearest structural behavior to the enhanced spun RC piles without joints. This numerical study will be used to further experimental study on the enhanced spun RC piles with reinforced joints.

Impact of Enhanced Recovery Program on Colorectal Cancer Surgery

  • Lohsiriwat, Varut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권8호
    • /
    • pp.3825-3828
    • /
    • 2014
  • Surgical outcomes of colorectal cancer treatment depend not only on good surgery and tumor biology but also on an optimal perioperative care. The enhanced recovery program (ERP) - a multidisciplinary and multimodal approach, or so called 'fast-track surgery' - has been designed to minimize perioperative and intraoperative stress responses, and to support the recovery of organ function aiming to help patients getting better sooner after surgery. Compared with conventional postoperative care, the enhanced recovery program results in quicker patient recovery, shorter length of hospital stay, faster recovery of gastrointestinal function, and a lower incidence of postoperative complications. Although not firmly established as yet, the enhanced recovery program after surgery could be of oncological benefit in colorectal cancer patients because it can enhance recovery, maintain integrity of the postoperative immune system, increase feasibility of postoperative chemotherapy, and shorten the time interval from surgery to chemotherapy. This commentary summarizes short-term outcomes and potential long-term benefits of enhanced recovery programs in the treatment of colorectal cancer.

입력강화와 출력강화 형태초점교수 상황에서의 한국 EFL 학습자들의 언어형태 지식개발에 관한 연구 (A Study on the Korean EFL Learners' Grammatical Knowledge Development under Input-enhanced FFI and Output-enhanced FFI Conditions)

  • 황희정
    • 디지털융복합연구
    • /
    • 제16권5호
    • /
    • pp.435-443
    • /
    • 2018
  • 본 연구의 목적은 형태초점교수법이 학습자의 언어형태에 관한 지식 향상에 미치는 영향을 조사하고, 학습자들이 그 형태에 관한 지식을 출력활동인 글쓰기에 어떻게 활용하는지를 살펴보는 것이다. 연구참여자들은 122명의 대학생들로 3개의 집단 즉 입력강화집단 35명, 출력강화집단 41명, 대조집단 46명으로 나누어 평가시험과 글쓰기 과제를 사전 사후로 실시하였다. 연구결과를 살펴보면, 입력강화 형태초점교수법과 출력강화 형태초점교수법 모두 학습자의 언어형태 학습에 영향을 미치는 것으로 드러났고, 학습자들이 이러한 형태초점교수법으로 습득한 지식을 영어글쓰기에 활용하는데 기여한 것으로 나타났다. 본 연구결과에 의거하여, 학습자의 언어형태 학습의 효과를 극대화할 수 있는 방법으로 입력강화와 출력강화기법을 적절하게 결합한 형태초점교수법을 적용할 것을 제안한다.

심근경색 모델에서 자기공명영상에 대한 비교 연구 (Comparative Study of the Magnetic Resonance Imaging in Myocardial Infarction model)

  • 임청환;정홍량;김정구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.19-22
    • /
    • 2001
  • The purpose of this study is to evaluate time course of signal enhancement on Gadomer-17 enhance MRI, and to correlate the size of enhanced area with that of the infarct area on 2'3'5'-triphenyl tetrazolium chloride(TTC) histochemical examination for the assessment of myocardial viability in reperfused Myocardial Infarction in a cat model. Tan cats(average weight: 3.8 kg) which had undergone 90 minutes of occlusion of the LAD followed by 90 minutes of reperfusion underwent MR T2-weighted imaging, and T1-weighted imaging, enhanced T1-weighted imaging. We used 1.5T Magneton Vision MRI system(Siemens, Erlangen, Germany). Signal intensities were measured in the enhanced and non-enhanced areas of enhanced T1-weighted imaging. and TTC histochemical staining the size of the abnormal signal area on each image was compared with that of the infarct area. Maximum enhancement was detected during a $40{\sim}60$ minute period with an average enhancement of $168{\pm}9.9%$ of normal myocardium. TTC staining revealed that the size of the high signal area on T2-weighted images and of the enhanced area on enhanced T1-weighted images was greater than that of the infarct area($T2=48.1%{\pm}3.7$, enhanced $T1=47.2%{\pm}2.6$, TTC $staining=38.7%{\pm}3.1$ ; p<0.05). In reperfused Myocardial Infarction in a cat model, enhanced MR imaging delineates reversibly and irreversibly damaged myocardium, with a strong enhancement and a broad temporal window. We may therefore expect that enhanced MR image is useful for demonstrating myocardial injury.

  • PDF