• Title/Summary/Keyword: Energy-efficiency

Search Result 11,162, Processing Time 0.051 seconds

Localization Scheme with Mobile Beacons in Ocean Sensor Networks (모바일 비콘을 이용한 해양 센서 네트워크의 위치 파악 기법)

  • Lee, Sang-Ho;Kim, Eun-Chan;Kim, Chung-San;Kim, Ki-Seon;Choi, Yeong-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1128-1134
    • /
    • 2007
  • Recently, sensor network technology is a highly concerned area due to the expectation of many applications in various fields. The application of sensor network technology to the marine and ocean surveillance and investigation makes the marine environmental research easier since intelligent sensor nodes substitute the human labor work. In ocean sensor network, the localization scheme for the sensor nodes is most essential because all the information without from sensor nodes might be useless unless the positional information of each sensor nodes is provided. In this paper, the localization scheme with mobile beacons in ocean sensor networks is suggested and showed it could be effective for applying to marine circumstances. Even though the previous localization scheme(Ssu's) has advantages that additional hardware is not required for obtaining the information of distance and angle and shows the high accuracy of location and energy efficiency and easy expandability as well, it has also demerits the location error increases as the minimum distance between the absolute positional information become closer. In our works, the improved localization scheme with the presumed area of sensor node using geometric constraints is suggested.

  • PDF

A Study on Time Synchronization Protocol to Cover Efficient Power Management in Ubiquitous Sensor Network (유비쿼터스 센서 네트워크를 위한 효율적인 시간 동기화 프로토콜 연구)

  • Shin, Moon-Sun;Jeong, Kyeong-Ja;Lee, Myong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.896-905
    • /
    • 2010
  • The sensor networks can be used attractively for various application areas. Time synchronization is important for any Ubiquitous Sensor Networks (USN) systems. USN makes extensive use of synchronized time in many contexts for data fusion. However existing time synchronization protocols are available only for homogeneous sensor nodes of USN. It needs to be extended or redesigned in order to apply to the USN with heterogeneous sensor nodes. Because heterogeneous sensor nodes have different clock sources with the SinkNode of USN, it is impossible to be synchronized global time. In addition, energy efficiency is one of the most significant factors to influence the design of sensor networks, as sensor nodes are limited in power, computational capacity, and memory. In this paper, we propose specific time synchronization based on master-slave topology for the global time synchronization of USN with heterogeneous sensor nodes. The time synchronization master nodes are always able to be synchronized with the SinkNode. Then time synchronization master nodes enable time synchronization slave nodes to be synchronized sleep periods. The proposed master-slave time synchronization for heterogeneous sensor nodes of USN is also helpful for power saving by maintaining maximum sleep time.

Development of State Diagnosis Algorithm for Performance Improvement of PV System (태양광전원의 성능향상을 위한 상태진단 알고리즘 개발)

  • Choi, Sungsik;Kim, Taeyoun;Park, Jaebeom;Kim, Byungki;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1036-1043
    • /
    • 2014
  • The installation of PV system to the power distribution system is being increased as one of solutions for environmental pollution and energy crisis. Because the output efficiency of PV system is getting decreased because of the aging phenomenon and several operation obstacles, the technology development of output prediction and state diagnosis of PV modules are required in order to improve operation performance of PV modules. The conventional methods for output prediction by considering various parameters and standard test condition values of PV modules may have difficult and complex computation procedure and also their prediction values may produce large error. To overcome these problems, this paper proposes an optimal prediction algorithm and state diagnosis algorithm of PV modules by using least square methods of linear regression analysis. In addition, this paper presents a state diagnosis evaluation system of PV modules based on the proposed optimal algorithms of PV modules. From the simulation results of proposed evaluation system, it is confirmed that the proposed algorithms is a practical tool for state diagnosis of PV modules.

Optical Monte Carlo Simulation on Spatial Resolution of Phosphor Coupled X-ray Imaging Detector (형광체 결합형 X선 영상검출기의 공간 해상력 몬테카를로 시뮬레이션)

  • Kang, Sang-Sik;Kim, So-Yeong;Shin, Jung-Wook;Heo, Sung-Wook;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.328-328
    • /
    • 2007
  • Large area matrix-addressed image detectors are a recent technology for x-ray imaging with medical diagnostic and other applications. The imaging properties of x-ray pixel detectors depend on the quantum efficiency of x-rays, the generated signal of each x-ray photon and the distribution of the generated signal between pixels. In a phosphor coated detector the light signal is generated by electrons captured in the phosphor screen. In our study we simulated the lateral spread distributions for phosphor coupled detector by Monte Carlo simulations. Most simulations of such detectors simplify the setup by only taking the conversion layer into account neglecting behind. The Monte Carlo code MCNPX has been used to simulate the complete interaction and subsequent charge transport of x-ray radiation. This has allowed the analysis of charge sharing between pixel elements as an important limited factor of digital x-ray imaging system. The parameters are determined by lateral distribution of x-ray photons and x-ray induced electrons. The primary purpose of this study was to develop a design tool for the evaluation of geometry factor in the phosphor coupled optical imaging detector. In order to evaluate the spatial resolution for different phosphor material, phosphor geometry we have developed a simulation code. The developed code calculates the energy absorption and spatial distribution based on both the signal from the scintillating layer and the signal from direct detection of x-ray in the detector. We show that internal scattering contributes to the so-called spatial resolution drop of the image detector. Results from the simulation of spatial distribution in a phosphor pixel detector are presented. The spatial resolution can be increased by optimizing pixel size and phosphor thickness.

  • PDF

Marinelli Beaker Measurement and Self Absorption Correction and Application for Various Environmental Samples in Monte Carlo Simulation (몬테카를로 시뮬레이션에서의 다양한 환경 샘플에 대한 Marinelli 비이커 측정 및 자기 흡수 보정과 적용)

  • Jang, Eun-Sung;Gim, Yang-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.605-611
    • /
    • 2017
  • The structure of the actual detector was computed using the code of the PENELOPE. Using the standard mixed sources (450, 1,000 ml), compare the effectiveness of each energy according to various densities and height of the PENELOPE computer simulation, and calculate the effectiveness of the various environmental specimens and apply them to various environmental specimens to determine the lower limit. The values obtained by the obtained value were obtained by applying the obtained efficiency to the actual environmental specimens and obtaining the lower limit values. The density correction factor is 1.155 g of the density correction factor of $0.4g/cm^3$ (59.54keV), 1.153 (661 keV), $1.06g/cm^3$ 1.064 (1,836.04keV), 1.03, and 1.033. It was confirmed that the radioactivity concentration of environmental samples decreased as the amount of specimen was measured increases, and the MDA value decreased as time measured increases.

Multiphonon relaxation and frequency upconversion of $Er^{3+}$ ions in heavy metal oxide glasses ($Er^{3+}$첨가 중금속 산화물 유리의 다중포논 완화와 주파수 상향 전이 현상)

  • Choi, yong-Gyu;Kim, Kyong-Hon;Heo, Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.221-226
    • /
    • 1998
  • Ternary heavy metal oxide glasses in the $PbO-Bi_2O_3-Ga_2O_3$ system doped with $Er_2O_3$ were prepared and their spectroscopic properties, such as radiative transition probability, calculated and measured radiative lifetimes and cross-sections of 1.5 $\mu\textrm{m}$ and 2.7 $\mu\textrm{m}$ emissions were analyzed. Enhanced quantum efficiencies of some electronic transitions were evident mainly because of the low vibrational phonon energy ($~500cm^{-1}$) inherent in the host glasses. This seems to be the main reason for obtaining the 2.7 $\mu\textrm{m}$ luminescence which is normally quenched in the conventional oxide glasses. In addition, green and red fluorescence emissions were observed through the frequency upconversion processes of the 798 nm excitation. Non-radiative transition due to the multiphonon relaxation is a dominant lifetime-shortening mechanism in the 4f-4f transitions in $Er^{3+}$ ion except for the $^4S_{3/2}{\rightarrow}^4I_{15/2}$ transition where a non-radiative transfer to band-gap excitation of the host glasses is dominant. Melting of glasses under an inert gas atmosphere and (or) addition of the typical glass-network former into glasses is necessary in order to enhance the quantum efficiency of the transition.

  • PDF

Anticancer Activity of Acer mono Wood Extracted by Ultra High Pressure Extraction Process (초고압 추출 공정을 통한 고로쇠 목부 추출물의 항암활성 증진)

  • Jeong, Myoung-Hoon;Choi, Woon-Yong;Seo, Yong-Chang;Kang, Ha-Young;Choi, Geun-Pyo;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.18 no.3
    • /
    • pp.157-167
    • /
    • 2010
  • We investigated a method to improve anticancer activities of Acer mono wood extracts by ultra high pressure extraction process. The A. mono was extracted by water at $40^{\circ}C$ and 300 MPa for 15 min (High Pressure Extraction, HPE). The extraction yield by ultra high pressure extraction process was 5.42%. The cytotoxicity on human normal lung cell (HEL299) of the extracts from HPE showed 21.54% lower than that from conventional water extraction at $100^{\circ}C$ in adding the maximum concentration of 1.0 mg/$m{\ell}$. Ultra high pressure extracts process for 15 minutes extracts (HPE15) showed more potent scavenging effect than the control, BHA. On SOD-like test, the HPE15 showed highest activity as 32.4% at 1.0 mg/$m{\ell}$ concentration. Human stomach adenocarcinoma, liver adenocarcinoma, breast adenocarcinoma and lung adenocarcinoma cell growth were inhibited up to about 67~79%, in adding 1.0 mg/$m{\ell}$ of extracts from HPE. HPE was 20~25% higher than conventional water extraction. It was interesting that, among several cancer cell lines (stomach adenocarcinoma, liver adenocarcinoma), the growth of digestive related cancer cells were most effectively inhibited as about 75~79%. On in vivo experiment using ICR mice, the variation of body weight of mice group treated A. mono wood extracts from HPE of 100 mg/kg/day concentration was very lower than control and other group. The survival times of group treated this extracts was 61.96% longer than that of the control group and this extracts showed the lower tumor weight, which were 10.49 g than positive control as 16.17 g. Based on these results, we could tell that the HPE wood extracts of A. mono had higher anticancer activity than conventional water extraction. The results of HPE showed obvious advantages in higher efficiency, shorter extraction time, at lower energy costs.

Filtration Characteristics of Membrane-coupled Fermentor System for Dissolved Organics Recovery From Liquid Organic Sludge (액상유기성슬러지로부터 용존유기물의 회수를 위한 막결합형 발효 시스템의 여과 특성)

  • Jong Oh Kim
    • Membrane Journal
    • /
    • v.13 no.2
    • /
    • pp.65-72
    • /
    • 2003
  • This study was focused on the investigation of filtration characteristics of membrane-coupled fermentor system for dissolved organics recovery from liquid organic sludge. On the filterability of MF over the range of $0.1{\sim}5 {\mu}m,$ the magnitude of total membrane resistance ($R_t$) is ranged as follows in the order; $0.1 {\mu}m>0.2{\mu}m>0.5 >1{\mu}m>2{\mu}m>5{\mu}m$. The cake layer resistance ($R_c$) occupied about 68~88% of total resistance with fermented sludge. Permeation flux decline was mainly attributed to the $R_c$, which was formed by a strong deposition from physico-chemical interactions of solids on membrane surface. Higher suspended solids (SS) concentration of suspension caused lower permeation flux. However, there was not a proportion relation beyond a certain SS concentration. The cross-flow velocity on the membrane surface was faster, which resulted in the higher permeation flux and also more efficient with low trans membrane pressure (TMP) in viewpoint of energy efficiency. The appropriate pH of suspension was over the range of 5.0~6.0 for dissolved organics recovery as well as the permeation flux. It is possible f3r bacteria to be separated perfectly with $0.1{\mu}m\; and \;0.2{\mu}m$ membrane pore size. Based on experimental results, most appropriate membrane pore size for the recovery is believed to around $1{\mu}m$.

High-k ZrO2 Enhanced Localized Surface Plasmon Resonance for Application to Thin Film Silicon Solar Cells

  • Li, Hua-Min;Zang, Gang;Yang, Cheng;Lim, Yeong-Dae;Shen, Tian-Zi;Yoo, Won-Jong;Park, Young-Jun;Lim, Jong-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.276-276
    • /
    • 2010
  • Localized surface plasmon resonance (LSPR) has been explored recently as a promising approach to increase energy conversion efficiency in photovoltaic devices, particularly for thin film hydrogenated amorphous silicon (a-Si:H) solar cells. The LSPR is frequently excited via an electromagnetic (EM) radiation in proximate metallic nanostructures and its primary con sequences are selective photon extinction and local EM enhancement which gives rise to improved photogeneration of electron-hole (e-h) pairs, and consequently increases photocurrent. In this work, high-dielectric-constant (k) $ZrO_2$ (refractive index n=2.22, dielectric constant $\varepsilon=4.93$ at the wavelength of 550 nm) is proposed as spacing layer to enhance the LSPR for application to the thin film silicon solar cells. Compared to excitation of the LSPR using $SiO_2$ (n=1.46, $\varepsilon=2.13$ at the wavelength of 546.1 nm) spacing layer with Au nanoparticles of the radius of 45nm, that using $ZrO_2$ dielectric shows the advantages of(i) ~2.5 times greater polarizability, (ii) ~3.5 times larger scattering cross-section and ~1.5 times larger absorption cross-section, (iii) 4.5% higher transmission coefficient of the same thickness and (iv) 7.8% greater transmitted electric filed intensity at the same depth. All those results are calculated by Mie theory and Fresnel equations, and simulated by finite-difference time-domain (FDTD) calculations with proper boundary conditions. Red-shifting of the LSPR wavelength using high-k $ZrO_2$ dielectric is also observed according to location of the peak and this is consistent with the other's report. Finally, our experimental results show that variation of short-circuit current density ($J_{sc}$) of the LSPR enhanced a-Si:H solar cell by using the $ZrO_2$ spacing layer is 45.4% higher than that using the $SiO_2$ spacing layer, supporting our calculation and theory.

  • PDF

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.