• 제목/요약/키워드: Energy variation

검색결과 2,917건 처리시간 0.038초

Wavelet Based Semblance and Eigenvalue Analysis for Geomagnetic Variation Related to Micro-Earthquakes in the Korean Peninsula

  • Ji, Yoon-Soo;Oh, Seok-Hoon;Kim, Ki-Yeon
    • 한국지구과학회지
    • /
    • 제33권5호
    • /
    • pp.408-421
    • /
    • 2012
  • The objective of this paper is to apply a newly developed wavelet-based semblance filtering and eigenvalue analysis to investigate the geomagnetic variations in some micro-earthquakes that had occurred in the Korean Peninsula. The wavelet-based filtering showed improved results in delineating the geomagnetic variations in relation to earthquake events from their background field. In addition, the eigenvalues analysis was also useful for the interpretation of three components geomagnetic fields during the earthquake events. The wavelet-based semblance analysis showed a prominent result for short-term geomagnetic variation related to the earthquake event, and the eigenvalue analysis was feasible to long-term geomagnetic variation. Considering the fact that the basement rock of the Korean Peninsula has a highly resistive electrical structure, it seems to be possible for small magnitude earthquakes to generate some distinguished geomagnetic variations.

태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템 (Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation)

  • 김홍성;최규하;유권종
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

직접분사식 수소기관의 사이클변동 원인해석에 관한 연구 (An Investigation on a Cause of Cycle Variation in Hydrogen Fueled Engine with Direct Injection)

  • 김윤영;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제13권3호
    • /
    • pp.233-241
    • /
    • 2002
  • To achieve hydrogen power system with high performance and stable operation, the COVimep of hydrogen fueled engine with direct injection was evaluated with the change of engine speed, injection timing, air-fuel equivalence ratio and spark timing. And the cause of cycle variation was analyzed by using coefficient of variation in combustion period defined in this study. the results showed that the cycle variation of hydrogen fueled engine is mainly dependent on the early combustion period.

크랭크축 각속도의 변동을 이용한 실린더내 압력 변화 추정(2) (Estimation of Cylinder Pressure Variation Using the Crankshaft Speed Fluctuation(2))

  • 임병진;박종범;임인건;배상수;김응서
    • 한국자동차공학회논문집
    • /
    • 제3권2호
    • /
    • pp.42-50
    • /
    • 1995
  • This paper proposes a new method to investigate combustion phenomena using the variation of crankshaft speed, From the idea that the variation of crankshaft speed contains the information of combustion, the energy method is applied as a single degree of freedom. Through the comparison of measured and calculated crankshaft speed, the proposed energy model is proved to be effective. When the crankshaft speed is used in the energy equation, filtering of the speed is required. The frequency components of cylinder pressure are analyzed and the coefficients of Fourier series above the twelfth frequency of engine speed are considered as a noise. As an example of application of this research, some combustion analyses like mean effective pressure, heat release rate, and misfire detection were carried out.

  • PDF

강우상태에 의한 소수력발전소 설계인자의 영향 (The Effects of Design Parameters for Small Scale Hydro Power Plant with Rainfall Condation)

  • 박완순;이철형
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.43-49
    • /
    • 2008
  • The effects of design parameters for small scale hydro power(SSHP) plants due to rainfall condition have been studied. The model to predict hydrologic performance for SSHP plants is used in this study. The results from analysis for rainfall conditions based on Weibull distribution show that the capacity and load factor of SSHP site had large difference between the variation of shape and scale parameter. Especially, the hydrologic performance of SSHP site due to variation of shape parameter varied more sensitive than the case of variation of scale parameter. And also, the methodology represented in this study can be used to decide the primary design specifications of SSHP sites.

BaZrO3의 부피 변화가 프로톤 전도 에너지 장벽에 미치는 영향 (Effect of Volume Variation on Energy Barrier for Proton Conduction in BaZrO3)

  • 정용찬;김대희;김병국;김영철
    • 한국세라믹학회지
    • /
    • 제47권5호
    • /
    • pp.474-478
    • /
    • 2010
  • We studied the energy barrier for proton conduction with volume variation in $BaZrO_3$ using a first principles study to investigate an optimum volume for the proton conduction. The volume increase of $BaZrO_3$ was expected to decrease the energy barrier for proton rotation and to increase that for proton transfer, and these trends could be extrapolated when the volume was decreased. However, the energy barriers for the proton transfer with the volume decrease were increased, while all the other energy barriers varied as expected. We could explain this unexpected behavior by the bent Zr-O-Zr structure, when the volume was decreased.

한국수영만에서 잔차류장의 운동 .위치에너지의 계절변화 (Seasonal Variation of Kinetic and Potential Energy of Residual Flow Field in Suyoung Bay, Korea)

  • 김동선;유철웅
    • 한국환경과학회지
    • /
    • 제6권4호
    • /
    • pp.313-322
    • /
    • 1997
  • 한국수영만에서 잔차류장의 운동 위치에너지의 계절변화를 연구하기 위하여 우리는 에너지의 수지를 계산하고 조석에너지와 비교했다. 위치에너지는 겨울과 봄철에 크며, 밀도성층이 형성된 여름과 초가을에 작게 나타났다. 잔차류의 운동에너지는 계절적인 변화를 보이고 있으며, 단위면 적당 잔차류의 평균 운동에너지는 6.4$\times$$10^{-4}ergs s^{-1}cm^{-}2$이다. 수영 만에서 잔차류장의 계절변동은 조석잔차류의 운동에너지가 밀도류나 취송류의 운동에너지보다 큰 11월을 제외하고는 밀도류가 지배하고 있다. 잔차류의 주성분인 조석잔차류, 취송류 및 밀도류의 운동에너지의 평균백분율은 잔차류의 운동에너지에 대하여 각각 29.1%, 3.4%, 67.5% 이다. 단위면적당 잔차류의 운동에너지, 위치에너지 및 조석에너지의 비는 각각 1.0 : 6.7$\times$$10^3$ : 8.2$\times$$10^4$ 이다.

  • PDF

수직형 태양광발전모듈의 계절별 일사획득 및 온도변화에 따른 출력특성 변화에 관한 연구 (Study on variation of electrical characteristics of vertical PV module according to the change of irradiance and temperature)

  • 박경은;강기환;김현일;유권종;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.57-62
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially the installation condition should be considered, for the generation performance of PV module is changed or the generation loss is appeared according to installation position, method, and etc. This study investigates variation of electrical characteristics of a PV module according to the change of irradiance and temperature. From this experimental study, we confirmed that the irradiance, the temperature variation and the generation performance of a PV module were appeared differently according seasonal variation. Actually the PV module installed in building facade showed high-generation performance in winter.

  • PDF

EFFECTS OF MECHANICAL PROPERTY VARIABILITY IN LEAD RUBBER BEARINGS ON THE RESPONSE OF SEISMIC ISOLATION SYSTEM FOR DIFFERENT GROUND MOTIONS

  • Choun, Young-sun;Park, Junhee;Choi, In-Kil
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.605-618
    • /
    • 2014
  • The effects of variability of the mechanical properties of lead rubber bearings on the response of a seismic isolation system are investigated. Material variability in manufacturing, aging, and operation temperature is assumed, and two variation models of an isolation system are considered. To evaluate the effect of ground motion characteristics on the response, 27 earthquake record sets with different peak A/V ratios were selected, and three components of ground motions were used for a seismic response analysis. The response in an isolation system and a superstructure increases significantly for ground motions with low A/V ratios. The variation in the mechanical properties of isolators results in a significant influence on the shear strains of the isolators and the acceleration response of the superstructure. The variation provisions in the ASCE-4 are reasonable, but more strict variation limits should be given to isolation systems subjected to ground motions having low A/V ratios. For application of seismic isolation systems to safety-related nuclear structures, the variation in the material and mechanical properties of the isolation system should be properly controlled during the manufacturing and aging processes. In addition, special consideration should be given to minimize the accidental torsion caused by the dissimilarity in the stiffness variations of the isolators.

웨이블렛 변환을 이용한 비선형 부하 전원선에서의 직렬 아크고장 신호 분석 (Analysis of Series Arc-Fault Signals Using Wavelet Transform From Non-linear Loads)

  • 방선배;박종연;장목순;최원호
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1470-1477
    • /
    • 2008
  • In this paper, a new detection method of series arc-fault signals occurring at the wiring of home appliances is proposed. The discrete wavelet transform was used for the numerical analysis of the variation rate in peak, RMS, noise energy, shoulder of the arc-fault current wave. As a results, the arc distinction threshold value of these variation rates was about 0.1 in most cases. The arc-fault current of the loads with the active PFC circuit showed a high rate of variation in noise energy and shoulder, but arc-fault current of the loads without the active PFC circuit showed a high rate of variation in peak and RMS. The arc fault current in resistive loads showed a high rate of variation in shoulder.