• 제목/요약/키워드: Energy transfer ratio

검색결과 405건 처리시간 0.029초

발포금속의 열전달 특성에 관한 실험적 연구 (Study on the Heat Transfer Characteristic of Metallic Foam)

  • 김필환;김미화;김영진;정효민;정한식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.618-623
    • /
    • 2008
  • To enhancement heat transfer performance, the metallic foam as heat exchanger was studied rapidly. This was attributed to its high surface area to volume ratio as well as intensive flow mixing by tortuous flow passages. So the experimental study about the heat transfer characteristic of metallic foam is presented in this paper. The material in this experiment was used as FeCrAl which has density of 10 ppi, 20 ppi and 30 ppi respectively. And the results show the heat transfer is rise with permeability Reynolds number increase and the pressure drop metallic foam was increased with the ppi increase.

  • PDF

관외착빙형 빙축열조의 방열성능 모델링 (Modelling of Thermal Discharge Performance for Ice-on-coil Type Ice-Storage Tank)

  • 이상렬;이경호;최병윤;한승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.280-285
    • /
    • 2001
  • This paper presents a modelling of thermal discharge performance for a static ice-on-coil ice-storage tank. Through the present study, discharging characteristics were examined with the existing results of theoretical and numerical heat transfer analyses. Also, an experiment was conducted to obtain a real set of discharge performance. The thermal effectiveness, the ratio of the actual heat transfer rate to the maximum possible heat transfer rate, decreased when the stored energy decreased during discharging period. And the effectiveness increased as the coolant flow rate through the storage increased, of which increasing rate decreased abruptly near the maximum and the minimum stored energy. An empirical correlation was obtained from the experimental and the numerical analysis data.

  • PDF

발열체가 있는 평행평판공간내의 대류열전달에 관한 수치해석 (A Study on Mixed Convection in Parallel Flat Plate with Heated Rectangular Block Arrays)

  • 정백영;이채문;임장순
    • 태양에너지
    • /
    • 제6권2호
    • /
    • pp.62-69
    • /
    • 1986
  • An analysis is made of the fully developed laminar flow and heat transfer in a parallel flat plate with heated rectangular block arrays to investigated the influence of bouyancy force. The shrouds is considered as adiabatic, while the heated block surface transmit a uniform rate of heat flux per unit axial length. The governing equations for velocity and temperature are solved by SIMPLE(Semi-Implicit Method Pressure Linked Equation) algorithm. Detailed velocity and temperature fields and overall heat transfer on wide range of Rayleigh number and various aspect ratios of heated rectangular blocks are computed. The result show that bouyancy leads to a significient enhancement in heat transfer along with a smaller increase in pressure drop, with the great enhancement found when the aspect ratio is 3.0.

  • PDF

삼상 Swirling 유동층에서 열전달 특성 (Characteristics of Heat Transfer in Three-Phase Swirling Fluidized Beds)

  • 손성모;신익상;강용;조용준;양희철
    • Korean Chemical Engineering Research
    • /
    • 제46권1호
    • /
    • pp.56-62
    • /
    • 2008
  • 직경이 0.102 m이고 높이가 2.5 m인 삼상 swirling(나선) 흐름 유동층에서 열전달 특성을 고찰하였다. 기체유속($U_G$), 액체유속($U_L$), 유동 입자의 크기($d_p$), 그리고 연속상인 액체의 나선 유도 흐름 액체량의 비($R_S$)가 유동층 내부 열원과 유동층간의 총괄 열전달 계수에 미치는 영향을 검토하였다. 유동층 내부 열원과 유동층간의 열전달 특성은 열원 표면과 유동층간의 온도차 요동 자료의 위상공간 투영과 Kolmogorov 엔트로피 해석으로 고찰할 수 있었으며, 나선 유도 흐름 액체량의 비($R_S$)가 0.1에서 0.4까지 증가할수록 온도차 요동 자료의 위상 공간 투영은 점점 안정되고 규칙성이 증대되는 상태를 나타내고, Kolmogorov 엔트로피 값은 감소하는 경향을 나타내었다. 열원 표면과 유동층간의 온도차 요동 자료의 Kolmogorov 엔트로피 값은 나선 유도 흐름 액체량이 증가함에 따라 최소값을 나타내었다. 열원과 유동층간의 총괄 열전달 계수는 기체 유속 및 유도입자의 크기가 증가함에 따라서 증가하였으나, 액체유속, 층공극률, 나선 유도 흐름 액체량의 비가 증가함에 따라서 최대값을 나타내었다. 내부 열원과 유동층간의 총괄 열전달 계수가 최대값을 나타낼 때의 액체의 유속 조건에서 온도차 요동자료의 Kolmogorov 엔트로피의 값도 최대값을 나타내었다. 삼상 나선흐름 유동층에서 열전달 계수와 Kolmogorov 엔트로피를 실험 변수 및 무차원군의 상관식으로 나타낼 수 있었다.

A Study on the Heat Transfer Enhancement of Miniature loop Heat Pipes by Using the Cu Nanofluids

  • Kim, Young-Sik;Jeong, Hyo-Min;Chung, Han-Shik;Tanshen, Md.Riyad;Lee, Dae-Chul;Ji, Myoung-Kuk;Bae, Kang-Youl
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.70-77
    • /
    • 2013
  • An experimental study was carried out to understand the heat transfer performance of a miniature loop heat pipes using water-based copper nanoparticles suspensions as the working fluid. The suspensions consisted of deionized water and copper nanoparticles with an average diameter of 80 nm. Effects of the cupper mass concentration and the operation pressure on the average evaporation and condensation heat transfer coefficients, the critical heat flux and the total heat resistance of the mLHPs were investigated and discussed. The pressure frequency also depends upon the evaporator temperature which has been maintained from $60^{\circ}C$ to $90^{\circ}C$. The Investigation shows 60% filling ratio gives the highest inside pressure magnitude of highest number pressure frequency at any of setting of evaporator temperature and 5wt% results the lowest heat flow resistance.

System-Level Analysis of Receiver Diversity in SWIPT-Enabled Cellular Networks

  • Lam, Thanh Tu;Renzo, Marco Di;Coon, Justin P.
    • Journal of Communications and Networks
    • /
    • 제18권6호
    • /
    • pp.926-937
    • /
    • 2016
  • In this paper, we study the feasibility of receiver diversity for application to downlink cellular networks, where low-energy devices are equipped with information decoding and energy harvesting receivers for simultaneous wireless information and power transfer. We compare several options that are based on selection combining and maximum ratio combining, which provide different implementation complexities. By capitalizing on the Frechet inequality, we shed light on the advantages and limitations of each scheme as a function of the transmission rate and harvested power that need to be fulfilled at the low-energy devices. Our analysis shows that no scheme outperforms the others for every system setup. It suggests, on the other hand, that the low-energy devices need to operate in an adaptive fashion, by choosing the receiver diversity scheme as a function of the imposed requirements. With the aid of stochastic geometry, we introduce mathematical frameworks for system-level analysis. We show that they constitute an important tool for system-level optimization and, in particular, for identifying the diversity scheme that optimizes wireless information and power transmission as a function of a sensible set of parameters. Monte Carlo simulations are used to validate our findings and to illustrate the trade-off that emerge in cellular networks with simultaneous wireless information and power transfer.

Experimental Investigations on the Temperature Characteristics of Oscillating Heat Pipe with Various Filling Ratio

  • Jeong, Hyo-Min;Chung, Han-Shik;Lee, Kwang-Sung;Tanshen, Md.Riyad;Lee, Tae-Jin;Lee, Sin-Il
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.47-53
    • /
    • 2013
  • The article focuses on the Temperature characteristics inside single loop oscillating heat pipe (OHPs). In this paper, heat pipe is experimentally studied thereby providing vital information on the parameter dependency of their thermal performance. The impact depiction has been done for the variation of tube model of the device. OHPs are made of copper capillary tubes of outer diameter 6.25 mm, inner diameter 4 mm heated by constant temperature water bath cooled by ambient temperature. Using four types of OHPs of copper capillary tubes length of 1500mm and HP length 650mm inside tubes working fluid is R-22 Pressure 8 bar and mass 34g,32g,28g,16g. The results indicate a strong influence of filling ratio on the performance.

항타장비의 성능평가 연구 (A Study on Hammer Performance Evaluation)

  • 홍헌성;이명환;조천환;김성회;전영석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.405-412
    • /
    • 2002
  • The performance of a hammer/driving systems is a major factor which affects bearing capacity and integrity of installed piles. Hammer performance can be evaluated from the results of dynamic pile testing using Pile Driving Analyzer(PDA). By comparing the rated energy with measured maximum transferred energy(EMX), the energy transfer ratio(ETR) can be calculated. This paper based on the dynamic measurements of 442 cases in 130 piling projects and evaluated ETR according to the hammer types(hydraulic and drop hammers) and pile types(steel and concrete piles).

  • PDF

Study on the mixing performance of mixing vane grids and mixing coefficient by CFD and subchannel analysis code in a 5×5 rod bundle

  • Bin Han ;Xiaoliang Zhu;Bao-Wen Yang;Aiguo Liu;Yanyan Xi ;Lei Liu ;Shenghui Liu;Junlin Huang
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3775-3786
    • /
    • 2023
  • Mixing Vane Grid (MVG) is one of the most important structures in fuel assembly due to its high performance in mixing the coolant and ultimately increasing Critical Heat Flux (CHF), which avoids the temperature rising suddenly of fuel rods. To evaluate the mixing performance of the MVG, a Total Diffusion Coefficient (TDC) mixing coefficient is defined in the subchannel analysis code. Conventionally, the TDC of the spacer grid is obtained from the combination of experiments and subchannel analysis. However, the processing of obtaining and determine a reasonable TDC is much challenging, it is affected by boundary conditions and MVG geometries. In is difficult to perform all the large and costing rod bundle tests. In this paper, the CFD method was applied in TDC analysis. A typical 5 × 5 MVG was simulated and validated to estimate the mixing performance of the MVG. The subchannel code was used to calculate the TDC. Firstly, the CFD method was validated from the aspect of pressure drop and lateral temperature distribution in the subchannels. Then the effect of boundary conditions including the inlet temperature, inlet velocities, heat flux ratio between hot and cold rods and the arrangement of hot and cold rods on MVG mixing and TDC were studied. The geometric effects on mixing are also carried out in this paper. The effect of vane pattern on mixing was investigated to determine which one is the best to represent the grid's mixing performance.

진동세관형 히트파이프를 이용한 태양열 집열기 개발에 관한 기초연구(I);작동유체의 내부 충진율과 경사각도의 영향 (Study on development of Solar Collector using Oscillating Capillary Tube Heat Pipe)

  • 김태훈;김종수;하수정;임용빈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1394-1399
    • /
    • 2004
  • Recently solar energy is representative in the technology development and spread of alternative energy. Specially in condition of solar collectors, they have had very various shape. This paper reports experimental study about the application of Oscillating Capillary Tube Heat Pipe to flat-plate solar collector. In conclusion, overall temperature distribution of OCHP was investigated by charging ratio and inclination angle. Respective charging ratio is 15%, 20%, 40% and respective inclination angle is horizontal, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, perpendicular. As a result of experiment, charging ratio 20% heat pipe has shown the most uniform temperature distribution and also performance of heat transfer has been the best.

  • PDF