A Cost Effective Energy Saving of Fluorescent Lighting in Commercial Buildings

  • Lee, Seong-Ryong;Nayar, Chemmangot V.
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.215-222
    • /
    • 2012
  • Lighting represents a significant component of commercial buildings, particularly office buildings. Fluorescent lighting is invariably used in all commercial, industrial and residential areas. A significant amount of lighting energy is wasted every day by leaving the lights on and not utilizing daylight energy. However, if daylight illuminance can be harnessed, this will reduce the electricity consumption of fluorescent lamps and save energy. This paper explains possible significant savings in lighting energy consumption and hence in costs, without reducing the performance and visual satisfaction in office or industrial buildings. It is proposed to obtain energy saving by reducing the supply voltage without degradation in lighting performance. Experimental results confirm that as much as 20% of electrical energy can be saved by reducing about 9% of the supply voltage, without noticeably affecting light output while complying with lighting standard limits.

Configuration and Efficiency Computation of the DPP System for Energy Harvesting of Renewable Energy (신재생에너지의 에너지 하베스팅을 위한 DPP시스템의 구성과 효율계산)

  • Park, Seung-Hwa;Lee, Hyun-Jae;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.3
    • /
    • pp.137-142
    • /
    • 2018
  • Energy harvesting technology is drawing attention as a means of collecting various eco-friendly energy and accumulating residual energy. Recently, differential power processing (DPP) is being developed as part of energy harvesting. This is being studied as a solution to the loss of power generation between power modules and the problems caused by module small losses depending on the size of power production. In this paper, we propose the necessity of the DPP by comparing and analyzing energy harvesting related module integration system and power supply efficiency of DPP. The power efficiency of the converter and the power difference between the wind power and the photovoltaic power supply have been changed to demonstrate the effectiveness of the proposed system.

Trends in Carbohyarate Supply as Energy Sources (에너지 급원식품(給源食品)으로서의 탄수화물(炭水化物)의 공급(供給)추세)

  • Lee, Young-Nam
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.15 no.3
    • /
    • pp.300-305
    • /
    • 1986
  • The contributing ratio and type of carbohydrate supply as an energy source were investigated for the period from 1974 to 1984. The major component of energy in food groups was cereals, but the cereals and potatoes were decreased almost steadily. The share from sugars, meats, oils, milk and eggs has been doubled with per capita income increase. Vegetable foods were consisted of 90% of total energy supply. In 1984, approximate 70% of the energy supply of cereals was provided by rice. The type and composition of carbohydrate supply were influenced by per capita income and food processing technology. Less carbohydrate intake and the ratio of complex carbohydrates to refined sugar and simple sugars also decreased.

  • PDF

Trend and Prediction of Environmental Resources Consumption in the Korean Peninsula (한반도 단위의 환경자원 소비량 추이와 예측)

  • Yeo, Min Ju;Kim, Yong Pyo
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.4
    • /
    • pp.261-279
    • /
    • 2016
  • Trends of food and energy consumptions in South Korea, North Korea, and the Korean Peninsula were shown and consumptions of food and energy for the integrated Korean Peninsula with several Cases were predicted, and the directions for the environmental resources management were suggested in this study. The Food Supply Quantity, the Protein Supply Quantity, and the Food Supply of North Korea were less than those of South Korea, the Eastern Asia, and World after 1990s. However, it is expected that the food consumption in North Korea will increase, if two Koreas are integrated. If the Food Supply Quantity of North Korea is the same as that of South Korea with the maximum projected population of integrated two Koreas by 2055, the food consumption in the Korean Peninsula would increase by 25% compared with the 2011 food consumption of integrated two Koreas. Thus, the choice of diet should be carefully considered and the increase of agricultural productivity is required. Energy consumption in North Korea is very small comparing to that of South Korea and fraction of coal in energy usage of North Korea is very high. If the energy consumption per capita of North Korea after integration be the same as that of South Korea in 2011, the energy consumption in the Korean Peninsula would increase by 45% compared with the 2011 energy consumption of integrated two Koreas. To minimize the environmental effects caused by energy consumption, the energy plan with the reduced fraction of coal in energy supply of North Korea should be adopted and advanced technology with higher efficiency should be applied to establish or expand the energy facility in North Korea.

A Rational Operation Scheduling Using Evolutionary Algorithm on Industrial Cogeneration System (산업용 열병합발전시스템에서 진화 알고리즘을 이용한 합리적 운전계획 수립에 관한 연구)

  • Choi, Kwang-Beom;Jeong, Ji-Hoon;Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.10
    • /
    • pp.494-501
    • /
    • 2000
  • This paper describes a strategy of a daily optimal operational scheduling in cogeneration system for paper mill. The cogeneration system selected to establish the scheduling consists of three units and several auxiliary devices. One unit generates electrical and thermal energy using the back pressure turbine. The rest two units generate the energy using the extraction condensing turbine. Three auxiliary boilers, two waste boilers and three sludge incinerators operate to supply energy to the loads with three units. The cogeneration system is able to supply enough the thermal energy to the thermal load, however it can not sufficiently supply the electrical power to the electrical load. Therefore the insufficient electric energy is compensated by buying electrical energy from utility. When the operational scheduling is performed considering the environmental problem. This paper shows the simulation results for daily operational scheduling obtained using the evolutionary algorithm. This results reveal that the proposed modeling and strategy can be effectively applied to cogeneration system for paper mill.

  • PDF

Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler) (외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석)

  • Kim, Ji-Hye;Aum, Tae-Yun;Jeong, Cha-Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

Applicability of reliability indices for water distribution networks (공급부하 시나리오에 따른 상수관망 신뢰도 지수의 적용성 분석)

  • Jeong, Gimoon;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.7
    • /
    • pp.441-453
    • /
    • 2017
  • Water distribution networks (WDNs) supply drinking water to end users by maintaining sufficient water pressure for reliable water supply in normal and abnormal conditions. To design and operate WDNs in efficient way, it is required to quantify water supply ability of the network. Various reliability indices have been developed and applied in this field. Most of the reliability indices are calculated based on the energy within a network; that is, the total energy entered the network, the energy dissipated through water supply process, and the energy finally supplied at the nodes, etc. This study explains the energy composition in WDNs and introduces three well-known reliability indices developed based on the energy composition of the network. The three indices were applied to a study network under various demand loading scenarios that could occur in real-life operation practices. This study aimed to investigate the applicability of the reliability indices under abnormal scenarios and proposed to illustrate the spatial distribution of the system reliability in more intuitive way for proper responses to the abnormal situations.

Proposition and Application of a Dish-Based Target Pattern for Korean Adolescent Girls (여자 청소년 음식 기반 권장식사패턴의 제안과 이를 적용하여 작성한 식단의 평가)

  • Park, Mi Jin;Kim, Youngnam
    • Korean Journal of Community Nutrition
    • /
    • v.20 no.2
    • /
    • pp.87-95
    • /
    • 2015
  • Objectives: Maintaining a balanced diet and thus health is crucial for adolescents, and the first step for balanced diet practice is meal planning. Adolescents, however, find it difficult to plan their meals. This study thus was set out to design an easier way of planning meals for adolescent girls. Methods: A dish-based target pattern for adolescent girls was tabulated, and validity of this was examined. Meal plan applying a dish-based target pattern was prepared by 150 female middle school students, and nutritional adequacies of those meal plans were examined. Validity and adequacy were tested by energy content, energy contribution ratio, nutrient adequacy ratio (NAR), probability of nutrient inadequacy, index of nutritional quality (INQ) calculation. Results: A dish-based target pattern with 11 dish groups was validated for nutritional adequacy. Though the NAR of calcium was 0.96, the INQ of calcium was 1.00. The average energy supply from the meal plans was 2,379 kcal, higher than the estimated energy requirement of a female middle school student, but the energy contribution ratio of carbohydrates, proteins, and fats were all adequate according to the acceptable macronutrient distribution range (AMDR). NAR of all nutrients examined were 1.0, except for calcium. The NAR and INQ of calcium were 0.87 and 0.75, respectively, and the meal plans at risk for calcium inadequacy was 19.30%. Conclusions: A dish-based target pattern proposed for adolescent girls was valid, but the meal plan prepared by female middle school students using this approach was high in energy and low in calcium supply. To cut down the energy supply from the meal plan, it is necessary to recommend dishes low in fat and use low fat cooking methods. To increase the calcium supply, it is important to recommend seaweed and legume group dishes with higher Ca INQ food items.

Power conversion control for zero emission buildings (탄소제로 빌딩을 위한 전력변환 제어)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.504-505
    • /
    • 2011
  • Decreasing actual greenhouse gas will be difficult if it is not solved addressed in architectural fields. Zero emission building or zero energy building, maximize the efficiency of energy, which means the building can operate by their own renewable energy facility without any other supplying. To be a zero emission building, a building needs realization of high efficiency low energy consumption, construction of building its own energy production facilities and lastly a power grid connection. According to increasing of DC load about TV, LED lighting, computer, IT in building for living and business, it is expected the save of energy when the system of AC power distribution change into the system of DC power distribution. Renewable energy exists a big different rate produced by outside environment. When electrical power overproduce, it can supply for system. Otherwise, if electrical power produce less, it can receive supply from system. Send and receive power can lead to zero to annual standard. This paper shows the simulation about efficient control of power conversion which is related to DC power distribution of architecture and DC output of renewable energy by using L-type converter.

  • PDF

Optimization of the Community Energy Supply System for D-Cube City, Multi Purpose Building (복합건물(D-Cube City) 지역에너지 공급체계 최적화)

  • Lee, Tae-Won;Kim, Yong-Ki;Lee, Kun-Woo;Lee, Ki-Bong;Cho, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.669-674
    • /
    • 2012
  • D-Cube City is a recently completed multi purpose building consisting of four types of facilities; offices, a department store, a hotel, and congregation spaces. A community energy supply system(CES) has been installed to supply this building with electricity, steam, heat, and cold water. The BEMS, building energy management system, is currently being designed to reduce building energy consumption through the efficient operation of the various pieces of building service equipment. In this study the optimal methods for operating the CES of D-Cube City were considered. This system includes three combined heat and power systems, seven steam boilers, two hot water boilers, two absorption chillers, and four turbo chillers, and various other pieces of equipment. In result, the optimal methods of operating the CES for various energy demand levels were obtained along with the seasonal effects on the economic efficiency of the operation. The effect of the amount of energy demanded by the various facility areas on the total energy consumption was also analyzed.