• Title/Summary/Keyword: Energy saving

Search Result 2,734, Processing Time 0.033 seconds

Experimental Test Results of Nine Scheduling Operational Modes of PV and Battery Hybrid System for the Development of Automatic Control Algorithm for Continual Operation without being shut-downed (태양광 배터리 Hybrid 전력공급시스템 9가지 운전 모드 시험결과 및 무고장 연속 운전을 위한 자동제어 알고리즘 개발)

  • Song, Taek Ho;Yang, Seung Kwon;Kim, Minjeong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • K-BEMS System was introduced to reduce peak load and to save total energy of the 200 buildings that KEPCO headquarter and branch offices use. And K-BEMS system is composed of PV, battery, and hybrid PCS. KEPCO research institute has carried out this K-BEMS research project for 3 years since January 2016. In this paper, the results of the project are shown. 9 modes of test results of K-BEMS system and are operational problems were analyzed. And measures to cure the trouble are also suggested. Batteries are operated more than 20% of SOC, and less than 20% of SOC battery protection switches are automatically shutting down the system and the system no longer respond to EMS, ending the supply of PV, and so therefore to continue the PV power supply it was turn out to be necessary that the EMS should automatically change its policy to change PV only supply mode automatically when the Battery Switch automatically operated. To operate the system continuously and automatically, it is necessary to modify the minimum operational SOC value, and in addition to that the EMS computer must remember the last shut-down SOC and Voltage which interrupted the system and add some margin to reflect the measurement error in the system.

Classification Method of Multi-State Appliances in Non-intrusive Load Monitoring Environment based on Gramian Angular Field (Gramian angular field 기반 비간섭 부하 모니터링 환경에서의 다중 상태 가전기기 분류 기법)

  • Seon, Joon-Ho;Sun, Young-Ghyu;Kim, Soo-Hyun;Kyeong, Chanuk;Sim, Issac;Lee, Heung-Jae;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.3
    • /
    • pp.183-191
    • /
    • 2021
  • Non-intrusive load monitoring is a technology that can be used for predicting and classifying the type of appliances through real-time monitoring of user power consumption, and it has recently got interested as a means of energy-saving. In this paper, we propose a system for classifying appliances from user consumption data by combining GAF(Gramian angular field) technique that can be used for converting one-dimensional data to the two-dimensional matrix with convolutional neural networks. We use REDD(residential energy disaggregation dataset) that is the public appliances power data and confirm the classification accuracy of the GASF(Gramian angular summation field) and GADF(Gramian angular difference field). Simulation results show that both models showed 94% accuracy on appliances with binary-state(on/off) and that GASF showed 93.5% accuracy that is 3% higher than GADF on appliances with multi-state. In later studies, we plan to increase the dataset and optimize the model to improve accuracy and speed.

Effect of Growing Part Following Local Heating for Cherry Tomato on Temperature Distribution of Crop and Fuel Consumption (방울토마토 생장부 추종 국소난방이 군락 온도분포 및 연료소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Lee, Tae Seok;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.217-225
    • /
    • 2015
  • Local heating system providing hot air locally to growing parts including shoot apex and flower cluster which were temperature-sensitive organs of cherry tomato was developed to reduce energy consumption for greenhouse heating without decline of crop growth. Growing part following local heating system was composed of double duct distributer which connected inner and outer ducts with hot air heater and winder which moved ducts up and down following growing parts with plant growth. Growing part local heating system was compared with conventional bottom duct heating system with respect to distributions of air and leaf surface temperatures according to height, growth characteristics and energy consumption. By growing part local heating, air temperature around growing part was maintained $0.9{\sim}2.0^{\circ}C$ higher than that of lower part of crop and leaf surface temperature was also stratified according to height. Investigations on crop growth characteristics and crop yield showed no statistically significant difference except for plant height between bottom duct heating and growing part local heating. As a result, the growing part local heating system consumed 23.7% less heating energy than the bottom duct heating system without decrease of crop yield.

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

Daesoon Jinrihoe Yeoju Headquarters Temple Complex as Viewed within Feng-Shui Theory (풍수지리로 본 대순진리회 여주본부도장)

  • Shin, Young-dae
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.33
    • /
    • pp.91-145
    • /
    • 2019
  • This study aims to reveal that Daesoon Jinrihoe Yeoju Headquarters Temple Complex is a sacred place of Gaebyeokgongsa (the Reordering Works of the Great Opening) through the logic of the energy of form in Feng-Shui studies. The Headquarters Temple Complex can illuminate the lamp of coexistence, emerge as a place for cultivation, and support the era of human nobility with Gucheonsangje (the Supreme God of the Ninth Heaven) as an object of faith. Virtuous Concordance of Yin and Yang, Harmonious Union between Divine Beings and Human Beings, the Resolution of Grievances for Mutual Beneficence, and Perfected Unification with Dao are the mission statements of this great site. For this purpose, it is necessary to investigate the headquarters according to integral Feng-Shui Theory. Doing so can provide proof that the geographic location, landscape, yin-yang harmonizing, and flowing veins of terrestrial energy at Headquarters Temple Complex are all profoundly auspicious. At the same time, this data also allows further study into the interactions of dragon-veins, energy hubs, surrounding mountains, and watercourses, which reveal how Daesoon Jinrihoe Yeoju Headquarters Temple Complex promotes the basic works of propagation, edification, and cultivation and three societal works of charity aid, social welfare, and education for the purpose of global propagation, saving beings, and building an earthly paradise by reforming humanity and engaging in spiritual civilization. This must be done on site with proper Feng-Shui in order to open up the era of human nobility upon the Great Opening of the Later World. As the center of the religious order, Daesoon Jinrihoe, Yeoju Headquarter Temple Complex has the general Feng-Shui characteristic of Baesanimsu (a back supported by a mountain and a front facing water). Through discussing the Feng-Shui of Daesoon Jinrihoe's Yeoju Headquarters Temple Complex as the center of humankind's resolution of grievances for mutual beneficence, this study would explore growth-supporting land that delivers future rewards through Feng-Shui symbolism and the ethical practice of grateful reciprocation of favors for mutual beneficence. This exploration will reveal how the geographical features and conditions of the Yeoju Headquarters Temple Complex make it a place fit for spiritual cultivation. It is a miraculous luminous court surrounded by mountains, where auspicious signs in eight directions gather. Its veins of terrestrial energy harmonize with clean water energy as it is affectionately situated within its natural environment. Its location corresponds with the Feng-Shui theory of dragon-veins, energy hubs, surrounding mountains, and watercourses. Thus, with regards to the Feng-Shui of Daesoon Jinrihoe's Yeoju Headquarters Temple Complex, this study examines the flows of mountains and waters and focuses on how the site is based on the logic of Feng-Shui. More generally, the geographical features of the surrounding mountains are likewise examined. An analysis of the relationship between Poguk (布局) of Sasinsa (animal symbols of the four directions, four gods, including blue dragon of the east, red phoenix of the south, white tiger of the west, and black tortoise of the north) and the location will be provided while focusing on the Yeoju Headquarters Temple Complex. This study supports the feasibility of further Feng-Shui studies of the Yeoju Headquarters Temple Complex based on traditional geomancy books that focusing on Hyeonggi (Energy of Form) Theory.

Thermogenesis and Motor Recruitment of the Pectoral Muscle During Shivering in Arousing Bats Murina Leucogaster

  • Choi, In-Ho;Lee, Youn Sun;Oh, Yung Keun;Jung, Noh-Pal;Gwag, Byoung Joo;Shin, Hyung-Cheul
    • Animal cells and systems
    • /
    • v.5 no.1
    • /
    • pp.31-35
    • /
    • 2001
  • Temperate-resident bats exhibit a circadian cycle of torpor and arousal In summer. The physiological role and selective advantage of torpor as an energy saving mechanism have been received much attention by hibernation biologists. However, despite the significance of the recovering euthermic function, the arousal process and mechanism in these animals have been poorly addressed. In this study, we investigated thermogenic and motor activities of a local bat species Murina leucogaster during arousal by simultaneously examining oxygen consumption rate, body temperature ($T_b$) and pectoral electromyography (EMG). We found that Tb of the torpid bats (12-14$^{\circ}C$) was augmented slowly by nonshivering mechanism during the initial awakening phase. The pectoral shivering, gauged by EMG activity, occurred between 17$^{\circ}C$ and 38$^{\circ}C$. Over this Tb range of shivering, heat was produced at a rate of 0.145 kcal $kg^{-1}\;min^{-1}$ to raise 1$^{\circ}C$ $T_b$ per min. Shivering was most intensive at 30-35$^{\circ}C$ where both EMG amplitude and spike frequency were the highest. Activation of the pectoral myofibers seemed to be controlled in a manner that motor units were recruited from smaller to larger sizes, with greater synchronization, as muscle shivering became intensive with increasing $T_b$.

  • PDF

Optimization of the Propeller Steady Performance Behind Wake Field

  • Lee, Wang-Soo;Choi, Young-Dal;Kim, Gun-Do;Moon, Il-Sung;Lee, Chang-Sup
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.2
    • /
    • pp.10-25
    • /
    • 2007
  • With the sharp increase of the oil price, the issue of the energy saving requires even higher propulsive efficiency of the propellers. Traditionally the propellers have been designed with the criteria such as that of Lerbs optimum based on the lifting line theory and the empirical formulae of Lerbs and van Manen giving relations of the wake pitch with the wake non-uniformity. With the aid of the high speed computer, it is now possible to apply the time-consuming iterative approaches for the solution of the lifting surface problems. In this paper we formulate the variational problem to optimize the efficiency of the propeller operating in the given ship wake using the lifting surface method. The variational formulation relating the spanwise circulation distribution with the propulsive efficiency to be maximized is however non-linear in circulation distribution functions, thus the iterative method is applied to the quasi-linearized equations. The blade shape design also requires the iterative procedures, because the shape of the blade which is represented by the lifting surface is unknown a priori. The numerical code was validated with the DTNSRDC propeller 4119 which is well-known to be optimum in uniform inflow condition. In addition existing (well-designed) commercial propellers were selected and compared with the results of the open water tests and the self-propulsion tests.

Implementation of Smart Multi-tap System based on Zigbee Communication (Zigbee 통신 기반 스마트 멀티탭 시스템 구현)

  • Lee, Jung-Hyuck;Kim, Sang-Hyun;Oh, Chang-Se;Seo, Min-Seok;Kim, Young-Don;Park, Hyun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.10
    • /
    • pp.930-936
    • /
    • 2014
  • Smart Multiple-Tap to be introduced in this paper, is an electronic device that controls the Multibple-Tap through the Smartphone. It runs on network and has an inbuilt Zigbee communication module. Thus, users can control home devices from remote through home server. Mentioned home server is operated as a gateway and is connected with smart devices on the Internet. To sum up, Users using this Smart Multiple-Tap can check the state information of the multi-tap ON/OFF and can control immediately by smartphone. also, Smart Multiple-Tap perfectly shut down the standby power. when users turn off each of the Smart Multiple-Tap's circle, It drives automatically lowest electricity-consuming mode and shut down the standby power by its own built-in SSR module. therefore, it will bring the energy saving effect on environment using Smart Multiple-Tap.

A STUDY ON THE FLOW CHARACTERISTICS OF AIR-KNIFE USING A CONSTANT EXPANSION RATE NOZZLE (팽창률이 일정한 노즐을 사용한 AIR-KNIFE 유동에 관한 연구)

  • Lee, Dong-Won;Kang, Nam-Cheol;Kim, Guen-Young;Kwon, Young-Doo;Kwon, Soon-Bum
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • In the process of continuous hot-dip galvanizing, it is well known that the gas wiping through an air knife system is most effective because of its uniformity in coating thickness, possibility of thin coating, workability in high speed, and simplicity of control. However, gas wiping used in the galvanizing process brings about a problem of splashing at the strip edge above a certain high speed of process. It is also known that the problem of edge splashing is more harmful than that at the mid strip surface. For a given liquid(of a certain viscosity and surface tension), the onset of splashing mainly depends upon the strip velocity, the gas-jet pressure, and the nozzle's stand-off distance. In these connections in the present study, we proposed three kinds of air knife system having nozzles of constant expansion rate, and compared the jet structures issuing from newly proposed nozzle systems with the result by a conventional one. In numerical analysis, the governing equations are consisted of two-dimensional time dependent Navier-Stokes equations, and the standard k-${\varepsilon}$ turbulence model is employed to solve turbulence stress and so on. As the result, it is found that we had better use the constant expansion-rate nozzle which can be interpreted from the point view of the energy saving for the same coating thickness. Also, we better reduce the size of separation bubble and enhance the cutting ability at the strip surface, by using an air-knife having constant expansion-rate nozzle.

A Numerical Analysis on the Coating Thickness in Continuous Hot-Dip Galvanizing (연속 아연 도금 코-팅 두께에 관한 수치 해석적 연구)

  • Lee, Dong-Won;Shin, Seung-Young;Kim, Byung-Ji;Kwon, Young-Doo;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2955-2960
    • /
    • 2007
  • To control the coating thickness of zinc in the process of continuous hot-dip galvanizing, it is known from early day that the gas wiping through an air knife system is the most effective because of the obtainable of uniformity of coating thickness, possibility of thin coating, working ability in high speed and simplicity of control. But, the gas wiping using in the galvanizing process brings about a problem of splashing from the strip edge for a certain high speed of coating. And, it is known that the problem of splashing is caused mainly by the existence of separation bubble at the neighbor of the strip surface. In theses connections, in the present study, we proposed two kinds of air knife systems having the same expansion rate of nozzle, and the jet structures and coating thicknesses from a conventional and new proposed nozzles are compared. In numerical analysis, the governing equations consisted of two-dimensional time dependent Navier-Stokes equations, standard ${\kappa}-{\varepsilon}$ turbulence model to solve turbulence stress and so on are employed. As a result, it is found that it had better to use the constant rate nozzle from the point view of the energy saving to obtain the same coating thickness. Also, to reduce the size of separation bubble and to enhance the cutting ability at the strip, it is recommendable to use an air knife having the constant expansion rate nozzle.

  • PDF