• 제목/요약/키워드: Energy plus

Search Result 463, Processing Time 0.031 seconds

Physiological responses of broiler chickens fed reduced-energy diets supplemented with emulsifiers

  • Oketch, Elijah Ogola;Lee, Jung Woo;Yu, Myunghwan;Hong, Jun Seon;Kim, Yu Bin;Nawarathne, Shan Randima;Chiu, Josh Wen-Cheng;Heo, Jung Min
    • Animal Bioscience
    • /
    • v.35 no.12
    • /
    • pp.1929-1939
    • /
    • 2022
  • Objective: To investigate the physiological effects of exogenous emulsifiers in broiler chickens that were fed tallow-incorporated reduced-energy diets over 35 days. Methods: A total of 256 Ross 308 one-day-old broilers (42.28±0.16 g) were randomly allocated in a 2×2 factorial arrangement to 32 pens with eight chicks per cage. Birds were fed one of four dietary treatments as follows: i) positive control (PCN; energy sufficient diet); ii) negative control (NCN; energy-deficient diet, -100 ME kcal/kg); iii) PCL (PCN plus 0.05% emulsifier); and iv) NCL (NCN plus 0.05% emulsifier). Growth performance was evaluated weekly whereas assessments for the carcass traits, digestibility, some blood metabolites, ileal morphology, and meat quality were measured on d 21 and d 35. Results: Birds fed the NCL diet had higher (p<0.05) body weights, daily gains, daily feed intake, and improved feed efficiency over the entire 35-day period. Improvements (p<0.05) for the ileal digestibility of crude fat, energy, and dry matter commensurate with longer (p<0.05) villus heights were also observed with emulsifiers in the NCL and PCL diets. For the carcass measurements, only the liver weights were increased (p<0.05) with emulsifiers in the supplemented groups. For blood metabolites, higher (p<0.05) lipase levels were noticed with emulsifiers in the NCL and PCL diets. In addition, marginal reductions (p = 0.076; p = 0.095, respectively) were also noted with emulsifiers for the total cholesterol and triglyceride contents on d 35. Regarding meat quality, breast muscle yellowness was increased (p<0.05) with emulsifier use in supplemented groups. Conclusion: Our results suggest that emulsifier supplementation at 0.05% in diets could potentially improve the growth performance and nutrient digestibility of broilers over 35 days. This could compensate for the lower growth performance that could be recorded with fat-incorporated lower-energy diets.

Energy constraint control in numerical simulation of constrained dynamic system

  • 윤석준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.376-382
    • /
    • 1991
  • In the analysis of constrained holonomic systems, the Lagange multiplier method yields a system of second-order ordinary differential equations of motion and algebraic constraint equations. Conventional holonomic or nonholonomic constraints are defined as geometric constraints in this paper. Previous works concentrate on the geometric constraints. However, if the total energy of a dynamic system can be computed from the initial energy plus the time integral of the energy input rate due to external or internal forces, then the total energy can be artificially treated as a constraint. The violation of the total energy constraint due to numerical errors can be used as information to control these errors. It is a necessary condition for accurate simulation that both geometric and energy constraints be satisfied. When geometric constraint control is combined with energy constraint control, numerical simulation of a constrained dynamic system becomes more accurate. A new convenient and effective method to implement energy constraint control in numerical simulation is developed based on the geometric interpretation of the relation between constraints in the phase space. Several combinations of energy constraint control with either Baumgarte's Constraint Violation Stabilization Method (CVSM) are also addressed.

  • PDF

Performance Prediction on the Application of a Ground-Source Heat Pump(GSHP) System in an Office Building (업무용 건물의 지열 히트펌프 시스템에 대한 성능 예측)

  • Sohn, Byonghu;Kwon, Han Sol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.9
    • /
    • pp.409-415
    • /
    • 2014
  • Ground-source heat pump (GSHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy efficiency. These systems use the ground as a heat source and the heat sink for cooling mode operation. The purpose of this simulation study is to evaluate the performance of a hypothetical GSHP system in an office building and to assess the energy saving effect against the existing HVAC systems (boiler and turbo chiller). We collected monthly energy consumption data from an actual office building ($32,488m^2$) in Seoul, and created a model to calculate the hourly building loads with EnergyPlus. In addition, we used GLD (Ground Loop Design) V8.0, a GSHP system design and simulation software tool, to evaluate hourly and monthly performance of the GSHP system. The energy consumption for the GSHP system based on the hourly simulation results were estimated to be 582.6 MWh/year for cooling and 593.2 MWh/year for heating, while those for the existing HVAC systems were found to be 674.5 MWh/year and 2,496.4 MWh/year, respectively. The seasonal performance factor (SPF) of the GSHP system was also calculated to be in the range of 3.37~4.28.

Application of the Solar Chimney System for Improving the Thermal Environment in Winter (겨울철 건물 열환경 개선을 위한 태양굴뚝 시스템의 응용)

  • Oh, Ju-Hong;Kim, Eui-Jong;Lee, Hyun-Soo;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.39-48
    • /
    • 2015
  • In this study, the solar chimney, one of the passive solar systems, is proposed as a method to improve the thermal environment of northern zones in buildings. As this well-known system has rarely been used in building projects, an adequate application of the system is proposed in this paper: the solar chimney system is designed to meet the required ventilation rate and consequently to reduce the ventilation load in the northern part of a building. To investigate such a possibility, a numerical model for the system is developed, and results of numerical tests are used for energy simulations. The results were taken into account for test simulations in EnergyPlus. As a result, approximately 75% of the volumetric ventilation rate required in the north zone could be supplied with the air volume acquired through the system and the monthly mean load was reduced by 29.5%, from 1.584 kWh to 1.117 kWh. The analyses of hourly mean heating and ventilation load over the heating period indicated that the system was very effective at around 13:00. Results show that 33% reduction in the ventilation load and 17% in the heating load for the north zone could be acquired through this system.

Intermittent Heating and Cooling Load Calculation Method -Comparing with ISO 13790

  • Lee, Sang-Hoon
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • College of Architecture, Georgia Institute of Technology, Atlanta, GA, US Abstract The intermittent heating and cooling energy need calculation of the ISO 13790 monthly method was examined. The current ISO 13790 method applies a reduction factor to the continuous heating and cooling need calculation result to derive the intermittent heating and cooling for each month. This paper proposes a method for the intermittent energy need calculation based on the internal mean temperature calculation. The internal temperature calculation procedure was introduced considering the heat-balance taking into account of heat gain, heat loss, and thermal inertia for reduced heating and cooling period. Then, the calculated internal mean temperature was used for the intermittent heating and cooling energy need calculation. The calculation results from the proposed method were compared to the current ISO 13790 method and validated with a dynamic simulation using EnergyPlus. The study indicates that the intermittent heating and cooling energy need calculation method using the proposed model improves transparency of the current ISO 13790 method and draws more rational outcomes in the monthly heating and cooling energy need calculation.

Economic Analysis of Various Residential Geothermal Heat Pump System Capacities (주택용 지열히트펌프 시스템의 용량 변화에 대한 경제성 비교 분석)

  • Lee, Chung-Kook;Suh, Seung-Jik;Kim, Jin-Sang
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.2
    • /
    • pp.1-9
    • /
    • 2011
  • Geothermal heat pumps are known as the most efficient and environment-friendly heating and cooling system, and are also gaining acceptance in buildings. Building energy simulation program, EnergyPlus is used to calculate the energy consumption of residential buildings. This simulated energy consumption is essential for accurate economic analysis. Residential buildings with geothermal heat pumps have complex energy price structure. Electricity rates for residential buildings increase rapidly as the monthly use increases. This complex energy price structure makes the economic analysis complicated. The purpose of this study is to conduct economic comparison of residential geothermal heat pumps and provide a feasible approach in finding their economically feasible capacity.

Evaluation of Onshore Wind Resource Potential According to Environmental Conservation Value Assessment (국토환경성평가에 의한 육상 풍력자원 잠재량 산정)

  • Kim, Hyun-Goo;Hwang, Hyo-Jung;Kang, Young-Heaok
    • Journal of Environmental Science International
    • /
    • v.22 no.6
    • /
    • pp.717-721
    • /
    • 2013
  • In order to analyze the effect of environmental protection on wind energy dissemination quantitatively, the onshore wind resource potential is estimated using Environmental Conservation Value Assessment Map and Korea Wind Resource Map. The onshore wind resource potential of 11 GW is calculated if wind farm development is prohibited within Class 1 area of Environmental Conservation Value Assessment plus 500 m buffer area. Therefore it is worried that environmental protection would be a practical barrier of accomplishing 4,155 thousand TOE target of wind energy dissemination until 2030.

A Preliminary Study the Effect of Occupancy Densities on Building Energy Consumption (재실밀도의 변화에 따른 건물에너지 사용량 분석을 위한 예비조사)

  • Choi, Jong-Dae;Yun, Geun-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.130-133
    • /
    • 2011
  • This paper reports the Survey results from a field monitoring study of office occupancy densities. The field measurement of a office in Yongin was carried out from 19 September to 30 September 2011. The survey has an aim to reveal the building energy consumption relationship between occupancy densities of a realistic office and the previous studies. The results showed that hourly occupied density of the previous studies is more higher than a field survey. we investigated the effects of difference occupancy densities on annual heating and cooling energy consumption using EnergyPlus. Heating and cooling consumption was raised because of the increased occupancy density. therefore, accurately measure the occupnacy schedule is important in order to reduce excessive building energy consumption, and is an significant element to be considered in the energy simulation.

  • PDF

A Case Study on the Design Variables Evaluation of Green Roof System effecting on Building Energy Conservation (건물 에너지 소비량에 영향을 미치는 옥상녹화시스템 설계변수 평가에 관한 사례 연구)

  • Choi, Jeong-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.3
    • /
    • pp.41-48
    • /
    • 2015
  • This study is to find out the major design variables of Green roof system effecting on the building energy consumption. Therefore, in three categories of green roof system, namely, foliage layer, soil layer and irrigation, 10 design variables are selected and simulated with one-story case building. Simulation is carried out with Design Builder and EnergyPlus. Finally, it was found out the effects of major variables affecting on the building heating and cooling energy and how they are affecting on the heating and cooling seasons respectively.

Effects of Pipe Network Materials and Distance on Unused Energy Source System Performance for Large-scale Horticulture Facilities (배관 재질 및 길이에 따른 대규모 시설원예단지용 미활용 에너지 시스템의 성능 평가)

  • Lee, Jae-Ho;Yoon, Yeo-Beom;Hyun, In-Tak;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.119-125
    • /
    • 2014
  • This study investigated the effects of pipe network materials and distance on system performance utilizing unused energy sources in large-scale horticulture facility. For this, the modeling was performed with a 100 m long and 100 m wide rectangular shaped glass house having an area of 1ha ($10,000m^2$) using EnergyPlus software. The heat sources considered were air source, geothermal heat, power plant waste heat, sea water heat, and river water. The temperature variation of the fluid with regard to pipe material and distance from the heat source and the resultant heat pump electricity consumptions were calculated. It turned out that the fluid temperature reaching the heat pump increased as the distance from the heat source increased in case of sea water and river water, which have higher temperatures than the surrounding soil, improving the heat pump efficiency. It was vice versa in case of the power plant waste heat. In addition, pipe material of PVC showed the smallest effect on the system performance variation due to the lowest thermal conductivity, compared to PB and HDPE.