• Title/Summary/Keyword: Energy plant

Search Result 3,892, Processing Time 0.031 seconds

Development of WT-FC Hybrid System for Off-Grid (오프그리드용 풍력-연료전지 하이브리드 시스템 개발)

  • Choi, Jong-Pil;Park, Nae-Chun;Kim, Sang-Hun;Kim, Byeong-Hee;Nam, Yun-Su;Yu, Neung-Su
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.383-386
    • /
    • 2007
  • This paper describes the design and integration of the wind- fuel cell hybrid system. The hybrid system components included a wind turbine, an electrolyzer (for generation of H2), a PEMFC (Proton Exchange Membrane Fuel Cell), storage system and BOP (Balance of Plant) system. The energy input is entirely provided by a wind turbine. A DC-DC converter controls the power input to the electrolyzer, which produces hydrogen and oxygen form water. The hydrogen used the fuel for the PEMFC. The hydrogen is compressed and stored in high pressure tank by hydrogen gas booster system.

  • PDF

Development of Filtration System for Korean Model IGCC Demonstation Plant (한국형 IGCC 대용량 집진시스템 개발)

  • Park, Seok-Joo;Lim, Kyeong-Soo;Lim, Jeong-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.812-815
    • /
    • 2007
  • Computational simulation has been performed to design the filtration system for Korea model IGCC demonstration plant. The filtration system for optimal design has four effective filters corresponding to the clusters composed of a group of ceramic candle filters. It was analyzed how the different entrance geometry influences the flow field and the particle behavior in the filtration system. The particle loading is minimum when the gas mixed with particles flows into the filter vessel with a shroud tube through a tangential inlet. However, the particle loading is maximum when the gas with particles enters the filter vessel through a normal inlet which a entrance tube extended from. By controling adequately both conditions of inflow, the filtration system can be operated optimally to prolong the filter life-time and to save the energy for cleaning filters.

  • PDF

Characterization of Graphite Oxide Reduced by Thermal and/or Chemical Treatments

  • Kim, Jungsoo;Nam, Dae-Geun;Yeum, Jeong Hyun;Suh, Sungbu;Oh, Weontae
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.274-279
    • /
    • 2015
  • Reduced graphite oxides (rGOs) were prepared by the common graphite oxidation method and the subsequent reductions. The reduction of graphite oxides (GOs) was conducted chemically and/or thermally. To further reduce the as-prepared rGOs, GOs were treated with chemical/thermal reductions or thermal/chemical reductions, in which the reduction sequence was also considered. The structural changes of as-prepared rGOs, depending on reduction methods, were investigated by X-ray diffraction analyses, Raman spectroscopy, X-ray photoelectron spectroscopy, and scanning electron microscopy. In addition, we discuss the structural change of the rGOs and their closely related physical and electrical properties, such as thermogravimetry, nitrogen adsorption isotherm, and sheet resistance.

A Study on the Optimum Design Flowrate for Tunnel-Type Small Hydro Power Plants

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.81-96
    • /
    • 1992
  • This study represents the methodology for feasibility analysis of small hydro power SHP plant. Cumulative density function of Weibull distribution and Thiessen method were adopted to decide flow duration curve at SHP candidate site. The perfomance prediction model and construction cost estimation model for tunnel-type SHP plant were developed. Eight tunnel -type SHP candidate sites existing on Han-river were selected and surveyed for actual site reconnaissance. The performance characteristics and economical feasibility for these sites were analyzed by using developed models. As a result, it was found that the optimum design flowrate with the lowest unit generation cost for tunel-type SHP candidate site were the flowrate concerming with between 20% and 30% of time ratio on the flow duration curve. Additionally, primary design specifications such as design flowrate, effective head, capacity, annual averageload factor, annual electricity production were estimated and discussed for eight surveyed SHP candidate sites.

  • PDF

Effect of Simetryne on Chloroplast-Mediated Electron Transport and Photoacoustic Signal (엽록체의 전자전달과 광음향 신호에 미치는 Simetryne의 영향)

  • 김현식
    • Journal of Plant Biology
    • /
    • v.31 no.3
    • /
    • pp.205-215
    • /
    • 1988
  • The effects of simetryne on light induced electron transport and phosphorylation in isolated spinach (Spinacia oleracea L.) chloroplasts were investigated in comparison with sencor and DCMU. Simetryne, like sencor and DCMU, completely, inhibited PSII electron transport and phosphoryltion with 10-6 M treatment but did not inhibit PSI electron transport. Interference with the electron transport pathway was evidenced by the greater sensitivity of oxygen evolution and uptake than phosphorylation. The following order of decreasing inhibitory effectiveness was exihibited; DCMU>simetryne>sencor. The photoacoustic technique was also used to monitor the relative photosynthetic activity in the leaves treated with the herbicides (simetryne, sencor or DCMU) in vivo and in vitro. Photoacoustic measurements on intact leaves provide quantitative information on two related aspects of the photosynthetic process, namely, photochemical energy storage and oxygen evolution. The relative photoacoustic signal of leaves treated with the herbicides showed low level in 21 Hz, but high level in 380 Hz and on isolated chloroplasts (both 21 Hz and 380 Hz) in comparison with that of the untreated leaves. These results suggest that some of photochemical energy is converted into the heat owing to the inhibition of electorn transport pathway by the herbicides.

  • PDF

Fundamental Study of Unit Proton Exchange Membrane Electrolysis for Realtime Detection of Tritium (실시간 삼중수소 검출을 위한 단위 양성자 교환 막 전기분해 기초연구)

  • CHAE, JONGMIN;YU, SANGSEOK
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.2
    • /
    • pp.226-234
    • /
    • 2018
  • Even though the nuclear power plants has many advantages, safety issues of nuclear power plants are crucial factors of reliable operation. A tritium detector is a useful sensor to analyze amount of exposed radiation from the nuclear power plants. Currently, concentration of underwater tritium is measured precisely but it takes very long time. Since electrolysis is extracted hydrogen from the coolant of nuclear power plant, it can motivate to develop new type of real-time sensor. In this study, Proton Exchange Membrane (PEM) electrolyzer is studied for candidate as preprocessor of real-time tritium detector. Characteristics of the unit PEM electrolyzer were experimentally investigated. A simulation model is developed to understand physical behavior of unit PEM electrolyzer under dynamic operation.

A STUDY ON THE SIMULTANEOUS MEASUREMENTS OF BETA EMITTING ISOTOPES

  • Lee, Goung-Jin;Kim, Seoung-Pyung
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.155-159
    • /
    • 2001
  • Beta radiation is measured for an environmental monitoring purpose or for an internal radiation exposure monitoring of nuclear power plant's worker. In korea, strontium 89 and strontium 90 is measured for an environmental monitoring purpose. Also tritium and carbon 14 contained in urine is measured for an internal radiation exposure monitoring of nuclear power plant's worker. Because above isotopes emits low energy beta radiations having a wide range of energy, very complicated isotope separation preprocess is needed. In this study, two mixed beta emitting isotopes are measured simultaneously using a liquid scintillation counter(LSC) and analyzed by using a developed statistical method. Banded least square method is used to analyze the mixed spectrum, and the goodness-of-fitness test is proposed. Test results show that the developed procedure can be very useful for analyzing a mixed beta emitting isotopes.

  • PDF

The Development of a Non-Intrusive Test of Check Valve Using Acoustics and Magnetics

  • Sim, Cheul-Muu;Choi, Ha-Lim;Baik, Heung-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.1E
    • /
    • pp.9-14
    • /
    • 1997
  • Check valves used in industrial and Nuclear Power Plant safety systems are susceptible to failure modes generally associated with wear of internal parts. Specifically, hinge pins, disc studs, pistons, and other mechanical parts may degrade over time, and in some cases, may which might produce a disabling event leading to plant or process shutdown. The primary diagnostic technique in the past has been to disassemble the valves. This procedure is costly, time consuming, and in the nuclear industry, it can lead to radiation exposure in some situations. Additionally repair and reassembly of a valve does not ensure proper operation. Non-intrusive diagnostic technologies including acoustics and magnetics with a digital signal analysis allow to evaluate check valve performance without a disassembly and is able to help the user detect degraded valve conditions.

  • PDF

Suggestion of a New Writer's Guideline to Reduce Human Errors Found in the Emergency Operation Procedures of a Nuclear Power Plant (비상운전절차서 작성과정의 인적오류 저감을 위한 지침서 제안에 관한 연구)

  • Lee, Dhong-Ha;Jang, Tong-Il;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.129-138
    • /
    • 2010
  • Gori-I nuclear power plant has been examining the effectiveness and efficiency of the current emergency operation procedures from human factors viewpoint. Previous study showed that some mistakes that the procedures did not comply with the writers' guidelines. Reviewing the current writers' guidelines for emergency operating procedures revealed that they lack of some important human factors rules such as enumeration of switching conditions and detailed action requirements, definite expression for setup points, description for anticipated results, and recommendation for use of present tense, affirmative sentence and active voice. This study suggested a new classification system for the writers' guideline contents supplementing the deficiencies of the current emergency operation procedure text.

A Simple Method for Assessing Severity of Common Root Rot on Barley

  • Arabi, Mohammad Imad Eddin;Jawhar, Mohammad
    • The Plant Pathology Journal
    • /
    • v.29 no.4
    • /
    • pp.451-453
    • /
    • 2013
  • Common root rot caused by Cochliobolus sativus is a serious disease of barley. A simple and reliable method for assessing this disease would enhance our capacity in identifying resistance sources and developing resistant barley cultivars. In searching for such a method, a conidial suspension of C. sativus was dropped onto sterilized elongated subcrown internodes and incubated in sandwich filter paper using polyethylene transparent envelopes. Initial disease symptoms were easily detected after 48h of inoculation. Highly significant correlation coefficients were found in each experiment (A, B and C) between sandwich filter paper and seedling assays, indicating that this testing procedure was reliable. The method presented facilitates a rapid pre-selection under uniform conditions which is of importance from a breeder's point of view.