• Title/Summary/Keyword: Energy per unit area

Search Result 173, Processing Time 0.031 seconds

The Comparative Analysis for the Economic Value of the Southern Part Cropping System Introducing New Bio-energy Crops. (영.호남 작부체계의 바이오에너지용 신품종 도입시 경제적 가치 비교분석)

  • Kim, Chung-Sil;Lee, Hyun-Keun
    • Korean Journal of Organic Agriculture
    • /
    • v.17 no.1
    • /
    • pp.1-17
    • /
    • 2009
  • The production of bio-energy crops is a major research project in the emphasizing the "low carbon green growth" strategy. For this, the possibility of the introduction of the new energy crops improve the agricultural income from fanning must be diagnosed. This study describes the level of agricultural income per unit area by cropping system based on the income of crops in the field. Especially, we have chosen the southern part attracting the attention in the possible area of the bio-energy crop production. This study consists of five chapters. Chapter I is the introduction. Chapter II is on the status of the southern part cropping system and the analysis of the economic value. Chapter III is on the economic value analysis introducing new bio-energy crops. Chapter IV is on the comparative analysis for the economic value of the croping system introducing new bio-energy crops. Chapter V is the conclusion.

  • PDF

Study on Temperature Variation by Greenhouse Soil Warming System Using Solar Thermal Energy (2) - Required Energy per Unit Area for Soil Warming - (태양열을 이용한 시설재배 지중변온가온의 토양 온도특성 연구(2) - 지중변온가온의 단위면적당 소요에너지 -)

  • Kim, Jin-Hyun;Kim, Tae-Wook;Nah, Kyu-Dong;Kim, Tae-Soo;Kim, Eun-Tae;Chung, Suk-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.35 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • The temperature of root zone was known as an important factor for the growth of crops and reduction of energy in greenhouse. The purpose of this study was to design the apposite inflow of calories per the unit area by comparison of temperature in the warmed and non-warmed soil. The energy needed for soil warming about pipe length showed the change of temperature on inflow and outflow as $2^{\circ}C{\sim}3^{\circ}C$(average $2.5^{\circ}C$). Therefore, the inflow per the unit hour was 3,450, 57,5 kcal/$h{\cdot}m^2$ on soil heating respectively. The non-warmed soil temperature in greenhouse made a difference by depth and it was partially affected inner temperature under 15 cm, but it was not above 15 cm. The soil temperature would be raised over $5^{\circ}C$ than non-warmed soil to increase effect of soil warming. Therefore, the inflow per the unit area that should be provided was about 100 kcal/$h{\cdot}m^2$.

A Study on the Greenhouse Gas Intensity of Building Groups and Regional in Korea (국내 에너지다소비건물의 용도별.지역별 온실가스 배출원단위분석 연구)

  • Lee, Chung-Kook;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.162-169
    • /
    • 2012
  • Our country set the mid-term reduction goal of greenhouse gases up to 2020 in accordance with Bali roadmap agreed in 2007 through the negotiation with UNFCCC in 2009 and specified the proper goal as by the Basic Act on Green Growth that went into effect at April, 2010. First of all the enlargement of green building construction has been suggested as a worldwide strategy to achieve the green house gas reduction. Building area is one of most important sectors for the countermeasure of climate change agreement and the achievement of national green house gas reduction goal and the need to reduce its green house gases has been increased accordingly. The objective of the study is to examine the status and characterization of mass energy consumption local governmental buildings' green house gas emissions depending on usage (hotel, school, apartment, hospital) through the green house gas emission source unit analysis. The result indicated that the energy source unit was proportional to green house gas source unit and hotel showed the highest green house gas emission source unit per open area of construction unit, followed by hospital, apartment, and then school. In case of apartment, green house gas emission source unit per open area of construction unit decreased as year went on. Meanwhile school building showed a striking increase in the annual energy source unit.

Analysis on Particle Cleaning Capacity of Indoor Air Cleaners for Different Flow Rates Considering Energy Consumption (에너지소비를 고려한 실내공기청정기의 풍량별 입자 청정화능력 분석)

  • Han, Bangwoo;Kang, Ji-Su;Kim, Hak-Joon;Kim, Yong-Jin;Won, Hyosig
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.139-147
    • /
    • 2013
  • The performances of indoor air cleaners including particle cleaning capacity and collection efficiency are usually tested at the condition of the maximum air flow rate of the air cleaners. However, the power consumption of the air cleaners is highly dependent on the air flow rate of the individual air cleaners. Therefore, there seems to be an optimized air flow rate for the air cleaning capacity considering power consumption. In this study, clean air delivery rate(or standard useful area as suggested room size) and power consumption have been investigated for different maximum air flow rates of 15 air cleaners and then compared those for different air flow rate modes of the individual 5 air cleaners selected from the 15 cleaners. For the maximum air flow rate conditions of 15 air cleansers, the power consumption per unit area was less related to the maximum air flow rate. However, for the different air flow rate modes of the selected 5 air cleaners, the lower power consumption per unit area was corresponding to the lower air flow rate mode of the individual air cleaners. When considering the operation time to the desired particle concentrations, there was an optimized one in the medium air flow rate modes for the individual air cleaners. Therefore, not only the maximum air flow rate but also lower air flow rates of individual air cleaners should be considered for estimating air cleaning capacity based on energy consumption per unit area.

A Study on Energy Efficiency Improvement through Building Insulation Diagnosis (건축물 단열 진단을 통한 에너지 효율 개선에 관한 연구)

  • Cho, Kwangmoon
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.3
    • /
    • pp.9-14
    • /
    • 2021
  • This paper discovers the energy loss factors through the insulation diagnosis of houses or buildings, and proposes directions for energy efficiency improvement. The energy efficiency factor of a building consists of insulation diagnosis, thermal bridge diagnosis, window diagnosis, airtight diagnosis, and equipment diagnosis. Among the residents and facilities in the energy welfare blind spot, an energy efficiency diagnosis was conducted for one senior citizen building located in Naju-si, Jeollanam-do, and energy efficiency diagnosis was conducted after insulation was installed. Energy measurement, diagnosis and analysis were performed using the IoT-based integrated wired/wireless energy diagnosis platform, Energy Finder. As a result of comparison, an overall energy saving rate of 16.38% was achieved. Annual heating energy consumption per unit area decreased from 333.51kWh before construction to 277.35kWh after construction, and annual cooling energy consumption per unit area decreased from 5.51kWh before construction to 5.22kWh after construction. The annual primary energy consumption per unit area decreased from 464.52kWh before construction to 403.69kWh after construction, and the annual energy cost was reduced from 3,063,307.14 won before construction to 2,641,072.49 won after construction. The additional improvement work is needed on the standards affecting energy efficiency other than insulation.

Evaluation of CO2 Storage and Uptake by Forest Landscapes in the Middle Region of Korea

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.139-149
    • /
    • 2013
  • Anthropogenic increases in greenhouse gas concentrations, primarily through radiative forcing from carbon dioxide, continue to challenge earth's climate. This study quantified $CO_2$ storage and uptake by dominant forest types and age classes in the middle region of Korea. In addition, the role of forest landscapes in reducing atmospheric $CO_2$ against $CO_2$ emissions based on energy consumption was evaluated. Mean $CO_2$ storage and uptake per unit area by woody plants for three forest types and four age classes were estimated applying regression equations derived to quantify $CO_2$ storage and uptake per tree; and computations per soil unit area were also performed. Total $CO_2$ storage and uptake by forest landscapes were estimated by extrapolating $CO_2$ storage and uptake per unit area. Results indicated mean $CO_2$ storage per unit area by woody plants and soils was higher in older age classes for the same forest types, and higher in broadleaved than coniferous forests for the same age classes, with the exception of age class II (11-20 years). $CO_2$ storage by broadleaved forests of age class V (41-50 years) averaged 662.0 t/ha (US$331.0 hundred/ha), highest for all forest types and age classes evaluated. Overall, an increased mean $CO_2$ uptake per unit area by woody plants was evident for older age classes for the same forest types. However, decreased $CO_2$ uptake by broadleaved forests at age class V was observed, compared to classes III and IV with an average of 27.9 t/ha/yr (US$14.0 hundred/ha/yr). Total $CO_2$ storage by woody plants and soils in the study area was equivalent to 3.4 times the annual $CO_2$ emissions, and woody plants annually offset the $CO_2$ emissions by 17.7%. The important roles of plants and soils were associated with 39.1% of total forest area in South Korea, and $CO_2$ emissions comprised 62.2% of the total population. Therefore, development of forest lands may change $CO_2$ sinks into sources. Forest landscape management strategies were explored to maintain or improve forest roles in reducing atmospheric $CO_2$ levels.

A Study on the Estimation model of the Amount of the Electric Energy Consumption according to the Apartment Heating Type (공동주택 난방방식별 전력에너지 소비량 추정모델 작성 연구)

  • Lee, Kang-Hee;Yang, Jae-Hyuk;Ryu, U-Sang
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • Electric energy is indispensible of the development of the industrial and living sector. Among the energy sectors, the building area shares 20% of the produced electric power in Korea. As we plan to supply the apartment, we need to forecast the required amount of the electric energy and supply the infrastructure to apartment for the lighting, cooling. Nonetheless, it is not easy to forecast the required amount of the electric energy, considering the management aspect, building physical aspect and social-geographic aspect. In this paper, it studied the estimation model of the electric energy, reflecting the affecting variables such as total area, number of household, geography and so on. The estimation model is proposed in 3-types which explained in central heating, individual heating and district heating, and each type have two estimation model, reflecting the affecting variable and corelation between variables to eliminate the muticolinearity. The unit of electric energy consumption per area and year is similar in three heating type and the results are as follows; the central heating is $34.446kWh/yr{\cdot}m^2$, individual type is $35.756446kWh/yr{\cdot}m^2$ and district heating is $34.285446kWh/yr{\cdot}m^2$.

Study on Evaluation Method of Thermal Potential of Unused Energy (미활용에너지의 열 포텐셜 평가 수법에 관한 연구)

  • Chung, Yong-Hyun
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.493-501
    • /
    • 2006
  • The increase in environmental loads and energy consumptions has resulted in the need of developed new forms of energy for a sustainable use for the society. Recently, the viability of using unused energy has attracted a great deal of attention. From the view point of using unused energy, the most critical problem can be referred to as the distance between the heat source/sink and heat demand area. The water resource in the city water system was used to solve this distance problem with unused energy. The calculation method of the potential use unit was used to survey the potential of the water resource in the city water system. The amount of theoretical unused energy and energy savings in the model city were estimated using this method. It is estimated that the amounts of energy savings and $CO_2$ reduction correspond to 131.3 GWh and 29280[t-C], respectively, per annual basis.

Experimental Study of Liquid Nitrogen Pool Spreading with Continuous Spill (연속적으로 누출되는 액체질소 풀의 확산에 관한 실험적 연구)

  • Choi, Jaewhan;Kim, Myungbae;Choi, Byungil;Kim, Taehoon
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.174-180
    • /
    • 2014
  • Experimental study of liquid nitrogen pool spread is carried out when it is continuously released. The liquid nitrogen spreads over a cement mortar plate with continuous release. Evaporation rate per unit area of the liquid nitrogen is measured using a digital balance, and a spreading distance of the liquid pool is measured by thermocouples. It is discovered that the evaporation rate per unit area of liquid nitrogen tends to decrease as the liquid pool spreads.

Seasonal Variation of Kinetic and Potential Energy of Residual Flow Field in Suyoung Bay, Korea (한국수영만에서 잔차류장의 운동 .위치에너지의 계절변화)

  • 김동선;유철웅
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.313-322
    • /
    • 1997
  • In order to study the seasonal variation of kinetic and potential energy of residual flow field In Suyoung Bay of Korea, we calculated Its energy budget and compared It with the tidal energy there. The potential energy shows the large value In winter and spring and the small one In summer and early autumn when the density stratification Is developed. The kinetic energy of residual flow varies seasonally and the seasonally averaged kinetic energy of residual flow per unit area is 6.4$\times$$10^{-4}ergs s^{-1}cm^{-}2$. It Is mainly governed by the density-driven current with the exception of that In November when the kinetic energy of tide-induced residual current is larger than those of density-driven current and wind-driven current. An averaged traction of the kinetic energy of tide-Induced residual current, wind-driven current and density-driven current, which are the major components of residual flow, is 29.1%, 3.4%, 67.5%, respectively, to the kinetic energy of residual flow, The fraction of kinetic energy of residual flow, potential energy and tidal energy per unit area is 1.0 : 6.7$\times$$10^3$: 8.2$\times$$10^4$ respectively.

  • PDF