• Title/Summary/Keyword: Energy losses

Search Result 710, Processing Time 0.035 seconds

Optimal Operation of Dispersed Generation in MicroGrid Systems (마이크로 그리드에서 분산전원의 최적 운영 방안)

  • Kim, Kyu-Ho;Rhee, Sang-Bong;Kim, Soo-Nam;Lee, Sang-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.486_487
    • /
    • 2009
  • This paper presents a method for optimal operation to improve reliability of MicroGrid systems considering load types and interruption cost. The objective functions such as power losses cost, operation cost of dispersed generations, power purchasing cost, and interruption cost are minimized for reliability improvement and efficient operation. The several indices for reliability evaluation are improved by renewable energy sources installation.

  • PDF

A ZVS-PWM Active-Clamping DC/DC Boost Converter (능동 클램프회로가 있는 영전압 PWM 방식을 이용한 DC-DC 승압형 컨버터)

  • 김태우;김기주;김학성;안희욱
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.622-625
    • /
    • 1999
  • This paper introduces a novel zero-voltage switching (ZVS)) pulse width modulation (PWM) active clamping dc-to-dc boost converter. This technique presents ZVS commutation without additional voltage stress and a significant increase in the circulating reactive energy throughout the converter. Therefore, all of the losses for the switches are minimized, and high power density system can be realized. The characteristics are verified through simulation and experimental results.

  • PDF

An Improved ZVZCS PWM FB DC/DC Converter Using the Modified Clamp Circuit (개선된 Clamp Circuit 적용 ZVZCS FB DC/DC 컨버터)

  • 김은수;조기연;김윤호;이진수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.643-645
    • /
    • 1999
  • The conventional high frequency phase-shifted full bridge dc/dc converter has a disadvantage that a circulating current flows through transformer and switching devices during the freewheeling interval. Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this paper provides a circulating current free type high frequency soft switching phase-shifted full bridge (FB) dc/dc converter with the modified energy recovery snubber (ERS) attached at the secondary side of transforemr.

  • PDF

Numerical Study on Performance of Centrifugal Compressor Volute (원심 압축기 볼루트 성능 해석)

  • Kim, Woo-June;Oh, Chang-Hoon;Cho, Kyung-Seok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.539-542
    • /
    • 2006
  • A volute (or scroll) of a centrifugal compressor collects the flows from impeller or diffuser, and passes it to a pipe at the exit. This flow still contains some kinetic energy which is not converted into pressure at diffuser, thus volute designer must concern the way to minimize losses. This study defines some variables which determine the shape of volute, and carry out computational analysis based on Design of Experiment to optimize the performance of volute.

  • PDF

The Characteristics on AC Losses and Construction of Prototype High-Tc Superconducting Cable (Prototype 고온 초전도 케이블의 제작 및 교류손실)

  • 김영석;이병성;정종만;백승명;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.97-100
    • /
    • 2000
  • Superconducting power cable is one of the most promising energy application of high-Tc superconductors (HTS). Thus, we investigated previously the characteristics on electrical and mechanical Bi-2223 Ag sheathed tape. And a prototype HTS cable have been designed, constructed and tested. The result shows that the transport current of HTS cable (1, 19-filament) in LN2 was 116[A], 240[A], respectively. And AC loss of HTS cable(19-filament) was 1.7 [W/m] in 240 [A] loading.

  • PDF

Radiation belt electron losses induced by wave-particle interactions

  • Summers, Danny
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.32.2-32.2
    • /
    • 2009
  • We examine cyclotron resonant interactions of radiation belt electrons with VLF chorus, plasmaspheric ELF hiss and electromagnetic ion cyclotron (EMIC) waves. Bounce-averaged diffusion rates depend on wave mode, equatorial pitch-angle, electron energy and L-shell. As well, diffusion rates can be sensitive to the latitudinal distributions of particle density and wave power. For different configurations of the plasmasphere, we calculate electron precipitation loss timescales due to combined scattering by VLF chorus, ELF hiss and EMIC waves.

  • PDF

Morphology of radio relics in galaxy clusters

  • Fernandez, Paola Dominguez
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.36.1-36.1
    • /
    • 2021
  • Galaxy clusters host Mpc-scale diffuse radio emission giving us evidence of large-scale magnetic fields in the Universe. It is relevant to understand magnetic field amplification processes occurring at the center and outskirts of galaxy clusters. Each of these processes are believed to give rise to observed radio haloes and radio relics, respectively. In this work, we focus on studying the continuum and polarised emission in radio relics. We use threedimensional magnetohydrodynamical simulations of merger shock waves propagating through a magnetized, turbulent intracluster medium. Our model includes the diffusive shock acceleration (DSA) of cosmic ray electrons, their spatial advection and energy losses at run-time. We discuss the relation between the mock observation features and the underlying morphology of the magnetic field.

  • PDF

Pulse Density Modulation Controlled Series Load Resonant Zero Current Soft Switching High Frequency Inverter for Induction-Heated Fixing Roller

  • Sugimura, Hisayuki;Kang, Ju-Sung;Saha, Bishwajit;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents the two lossless auxiliary inducors-assisted voltage source type half bridge(single ended push pull:SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation forwide its output power regulation ranges and load variations under constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operatprinciple is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation charactertics-based on the high frequency PDM strategy. The experimenoperating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimenones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliimplemented here is proved from the practical point of view.

  • PDF

DC-Voltage Regulation for Solar-Variable Speed Hybrid System (태양광 기반의 가변속 하이브리드 시스템을 위한 직류 전압 제어)

  • Niyitegeka, Gedeon;Lee, Kyungkyu;Choi, Jaeho;Song, Yujin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.231-237
    • /
    • 2016
  • Recently, the interest in DC systems to achieve more efficient connection with renewable energy sources, energy storage systems, and DC loads has been growing extensively. DC systems are more advantageous than AC systems because of their low conversion losses. However, the DC-link voltage is variable during operation because of different random effects. This study focuses on DC voltage stabilization applied in stand-alone DC microgrids by means of voltage ranges, power management, and coordination scheme. The quality and stability of the entire system are improved by keeping the voltage within acceptable limits. In terms of optimized control, the maximum power should be tracked from renewable resources during different operating modes of the system. The ESS and VSDG cover the power shortage after all available renewable energy is consumed. Keeping the state of charge of the ESS within the allowed bands is the key role of the control system. Load shedding or power generation curtailment should automatically occur if the maximum tolerable voltage variation is exceeded. PSIM-based simulation results are presented to evaluate the performance of the proposed control measures.

Selection of Oxygen Carrier Candidates for Chemical Looping Combustion by Measurement of Oxygen Transfer Capacity and Attrition Loss (산소전달량 및 마모손실 측정에 의한 매체순환연소용 산소전달입자 후보 선정)

  • KIM, HANA;PARK, JAEHYEON;BAEK, JEOM-IN;RYU, HO-JUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.4
    • /
    • pp.404-411
    • /
    • 2016
  • To select appropriate oxygen carrier candidates for chemical looping combustion, reduction characteristics of seven oxygen carriers were measured and discussed using three different reduction gases, such as $H_2$, CO, and $CH_4$. Moreover, attrition losses of those oxygen carriers also measured and compared. Among seven oxygen carrier particles, OCN703-1100 and NiO/bentonite particles showed higher oxygen transfer capacity than other particles, but these particles showed more attrition loss than other particles. C14 and C28 particles which used as cheap oxygen carriers in European country showed lower oxygen transfer capacity and less attrition loss. Based on the experimental results, we could select OCN717-R1SU, NC001, and N002 particles as candidates for future works because these oxygen carriers showed enough oxygen transfer capacity and good attrition resistance.