• 제목/요약/키워드: Energy generator

검색결과 1,837건 처리시간 0.024초

A Safety Analysis of a Steam Generator Module Pipe Break for the SMART-P

  • Kim Hee Kyung;Chung Young-Jong;Yang Soo-Hyung;Kim Hee-Cheol;Zee Sung-Quun
    • International Journal of Safety
    • /
    • 제3권1호
    • /
    • pp.53-58
    • /
    • 2004
  • SMART-P is a promising advanced small and medium category nuclear power reactor. It is an integral type reactor with a sensible mixture of new innovative design features and proven technologies aimed at achieving a highly enhanced safety and improved economics. The enhancement of the safety and reliability is realized by incorporating inherent safety improving features and reliable passive safety systems. The improvement in the economics is achieved through a system simplification, and component modularization. Preliminary safety analyses on selected limiting accidents confirm that the inherent safety improving design characteristics and the safety system of SMART-P ensure the reactor's safety. SMART-P is an advanced integral pressurized water reactor. The purpose of this study is for the safety analysis of the steam generator module pipe break for the SMART-P. The integrity of the fuel rod is the major criteria of this analysis. As a result of this analysis, the safety of the RCS and the secondary system is guaranteed against the module pipe break of a steam generator of the SMART-P.

Capacitive Switching Antenna의 최적 에너지 전달에 관한 연구 (A Study on Optimizing Energy Transfer of Capacitive Switching Antenna)

  • 김진만;방정주;허창수
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.232-238
    • /
    • 2013
  • In this paper we describe the maximum energy transfer of CSA(Capacitive Switching Antenna). CSA which is radiated antenna system contain energy storage and switch, antenna needs to high voltage source for electrical field radiation experiment. In this experiment we employed Marx generator as a charging source. CSA can radiate electrical field more efficiently by varying antenna capacitance. The electromagnetic generation system which was using CSA has some advantages which are more simple and more effective compared to exist system. We evaluated the performance of electromagnetic wave generating system using CSA. As a result UWB gain of system is 0.47, It is higher level than exist system is 0.3. Radiated electrical field strength at 1m is 70kV/m. It is measured by D-dot sensor and gap distance is 20mm. Center frequency of CSA is approximately 25MHz. When vary the antenna gap distance from 50mm to 20mm, we can find the radiation field strength is decrease and antenna center frequency is increased. We also simulated the energy transfer efficiency to compare with experiment result. Consequentially, CSA needs to appropriate capacitance which is similar value from marx generator for maximum energy transfer, and gap is less than 1mm to increase the CSA capacitance.

Preliminary Study on Separation of Germanium and Gallium for Development of a 68Ge/68Ga Generator

  • Lee, Heung Nae;Kim, Sang Wook;Park, Jeong Hoon;Kim, Injong;Yang, Seung Dae;Hur, Min Goo
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.101-106
    • /
    • 2011
  • The separation of germanium and gallium ion with metal oxide was introduced into the development of $^{68}Ge/^{68}Ga$ generator. Germanium and gallium within mixed solution were respectively separated by using a liquid-liquid extraction and a column chromatographic method. The separation of Ge within high concentrated hydrochloric and sulfuric acid was conducted by the extraction to $CCl_4$ and the back-extraction to 0.05 M HCl. An optimum condition of the extraction by $CCl_4$ was in 5~7 M HCl and efficiency was around 80%. The gallium was selectively separated by using $Al_2O_3$ among metal oxides as sorbents from the mixed solution in 0.04~0.10 M HCl condition.

Signal processing method of bubble detection in sodium flow based on inverse Fourier transform to calculate energy ratio

  • Xu, Wei;Xu, Ke-Jun;Yu, Xin-Long;Huang, Ya;Wu, Wen-Kai
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3122-3125
    • /
    • 2021
  • Electromagnetic vortex flowmeter is a new type of instrument for detecting leakage of steam generator, and the signal processing method based on the envelope to calculate energy ratio can effectively detect bubbles in sodium flow. The signal processing method is not affected by changes in the amplitude of the sensor output signal, which is caused by changes in magnetic field strength and other factors. However, the detection sensitivity of the electromagnetic vortex flowmeter is reduced. To this end, a signal processing method based on inverse Fourier transform to calculate energy ratio is proposed. According to the difference between the frequency band of the bubble noise signal and the flow signal, only the amplitude in the frequency band of the flow signal is retained in the frequency domain, and then the flow signal is obtained by the inverse Fourier transform method, thereby calculating the energy ratio. Using this method to process the experimental data, the results show that it can detect 0.1 g/s leak rate of water in the steam generator, and its performance is significantly better than that of the signal processing method based on the envelope to calculate energy ratio.

이중벽관 증기발생기의 설계개념 기술개발 (Design Concept and Technology Development of a Double-Wall-Tube Steam Generator)

  • 남호윤;최병해;김종범
    • 대한기계학회논문집A
    • /
    • 제34권9호
    • /
    • pp.1217-1225
    • /
    • 2010
  • 소듐을 냉각재로 사용하는 고속로의 증기발생기에서는 소듐과 물의 화학적 반응을 최소화하는 것이 중요한 문제이다. 소듐과 물의 반응 가능성을 줄여 증기발생기의 신뢰성을 향상시키기 위한 한가지 방안으로 이중벽관을 전열관으로 사용하는 증기발생기를 개발하고 있다. 이 증기발생기에서 중요한 현안은 이중벽관에서의 열전달 성능을 향상시키는 문제와 원자로 운전 중에 소듐과 물 반응사고가 일어나기 전에 전열관의 파손을 감지하는 기술을 개발하는 것이다. 이 논문에서는 이 현안을 극복할 수 있는 방안을 제시하였고, 이 기술을 활용하여 증기발생기의 개념을 설계하였다. 또한 이 개념에 적용되는 이중벽관을 설계 및 예비 제작하여 기계적 시험을 수행하였다.

Hydrodynamic Design of Thrust Ring Pump for Large Hydro Turbine Generator Units

  • Lai, Xide;Zhang, Xiang;Chen, Xiaoming;Yang, Shifu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권1호
    • /
    • pp.46-54
    • /
    • 2015
  • Thrust-ring-pump is a kind of extreme-low specific speed centrifugal pump with special structure as numerous restrictions from thrust bearing and operation conditions of hydro-generator units. Because the oil circulatory and cooling system with thrust-ring-pump has a lot of advantages in maintenance and compactness in structure, it has widely been used in large and medium-sized hydro-generator units. Since the diameter and the speed of the thrust ring is limited by the generator set, the matching relationship between the flow passage inside the thrust ring (equivalent to impeller) and oil bath (equivalent to volute) has great influence on hydrodynamic performance of thrust-ring-pump. On another hand, the head and flow rate are varying with the operation conditions of hydro-generator units and the oil circulatory and cooling system. As so far, the empirical calculation method is employed during the actual engineering design, in order to guarantee the operating performance of the oil circulatory and cooling system with thrust-ring-pump at different conditions, a collaborative hydrodynamic design and optimization is purposed in this paper. Firstly, the head and flow rate at different conditions are decided by 1D flow numerical simulation of the oil circulatory and cooling system. Secondly, the flow passages of thrust-ring-pump are empirically designed under the restrictions of diameter and the speed of the thrust ring according to the head and flow rate from the simulation. Thirdly, the flow passage geometry matching optimization between thrust ring and oil bath is implemented by means of 3D flow simulation and performance prediction. Then, the pumps and the oil circulatory and cooling system are collaborative hydrodynamic optimized with predicted head-flow rate curve and the efficiency-flow rate curve of thrust-ring-pump. The presented methodology has been adopted by DFEM in design process of thrust-ring-pump and it shown can effectively improve the performance of whole system.

실험실용 독립형 하이브리드 에너지 시스템의 가능성 연구 (Pre-Feasibility Study of Stand-Alone Hybrid Energy System for Applications in a Lab)

  • 이영;최용성;장우새;이경섭
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.627-631
    • /
    • 2009
  • As renewable and sustainable energy, solar energy and wind energy have advantages in reducing the pollution sources. The paper presents a hybrid system which includes the solar cell and the wind generator. HOMER provides a platform to design and simulate the power system and then to choose the optimization results. This paper simulates with the HOMER and performs a pre-feasibility study of stand-alone hybrid energy systems for applications in a lab.

Derivation of Damping-reflected Energy Functions in COI Formulation for Direct Analysis of Transient Stability

  • Park, Byoung-Kon;Kwon, Yong-Jun;Lee, Jong-Gi;Moon, Young-Hyun
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.134-140
    • /
    • 2004
  • This paper presents an improved group of energy functions reflecting generator damping effects for multi-machine power systems by using Center of Inertia (COI) formulation as an extension of the previous work. Since rotor angles at the Stable Equilibrium Point (SEP) of post-fault systems are generally calculated in COI, system transient energy can be found without assumption of infinite or slack bus, which is a crucial drawback of the absolute rotor angle frame approach. The developed energy functions have a structure preserving property with which it is very flexible to incorporate various models of power system components, especially various load and generator models. The proposed damping-reflected energy functions are applied to the Potential Energy Boundary Surface (PEBS) method, one of the direct methods. Numerical simulation of WSCC 9-bus shows that conservativeness of the PEBS method can be considerably reduced.

Development of A Floating Solar Thermoelectric Generator Using A Dome Shaped Fresnel Lens for Ocean Application

  • Seong-Hoon Kim;Jeung-Sang Go
    • 한국산업융합학회 논문집
    • /
    • 제26권6_1호
    • /
    • pp.1001-1010
    • /
    • 2023
  • To solve the problem that photovoltaic panels can not harvest electrical energy at a cloudy day and night, a floating solar thermoelectric generator (FSTEG, hereafter) is studied. The FSTEG is consisted of a dome shaped Fresnel lens to condense solar energy, a thermoelectric module connected with a heat sink to keep temperature difference, a floating system simulating a wavy ocean and an electrical circuit for energy storage. The dome shaped Fresnel lens was designed to have 29 prisms and its optical performance was evaluated outdoors under natural sunlight. Four thermoelectric modules were electrically connected and its performance was evaluated. The generated energy w as stored in a Li-ion battery by using a DC-DC step-up converter. For the application of ocean environment, the FSTEG was covered by the dome shaped Fresnel lens and sealed to float in a water-filled reservoir. The harvested energy shows a potential and a method that the FSTEG is suitable for the energy generation in the ocean environment.

가변 펌핑 클록 주파수를 이용한 모바일 D램용 고효율 승압 전압 발생기 (An Energy Efficient $V_{pp}$ Generator using a Variable Pumping Clock Frequency for Mobile DRAM)

  • 김규영;이두찬;박종선;김수원
    • 대한전자공학회논문지SD
    • /
    • 제47권6호
    • /
    • pp.13-21
    • /
    • 2010
  • 본 논문에서는 가변 펌핑 클록 주파수를 이용한 모바일 D랩용 고효율 승압 전압 발생기를 제안한다. 제안된 승압 전압 발생기는 효율을 높이기 위해서 3단 Cross-coupled 점하 펌프를 사용하였으며, 또한 최종 출력 전압의 승압 시간을 줄이기 위해 기존의 승압 전압 발생기에서 사용되는 고정된 펌핑 클록 주파수 대신 전압 제어 발생기를 사용하여 펌핑 클록 주파수을 가변하였다. 따라서 제안된 승압 전압 발생기는 1.2 V 전원 전압, 최대 2 mA의 부하 전류, 1 nF의 부하 캐퍼시터 조건에서 24.0-${\mu}s$안에 3.0 V의 최종 출력 전압을 승압할 수 있다. 실험 결과 제안된 승압 전압 발생기는 에너지 소비를 26% (1573 nJ $\rightarrow$ 1162 nJ), 승압 시간을 29% (33.7-${\mu}s$ $\rightarrow$ 24.0-${\mu}s$) 감소시켰다. 따라서 제안된 승압 전압 발생기를 사용함으로써, 높은 에너지 효율과 빠른 승압을 동시에 구현할 수 있다.