• Title/Summary/Keyword: Energy generator

Search Result 1,842, Processing Time 0.031 seconds

A Voltage Vector Synchronization Method for a Renewable Energy System with a Doubly-Fed Induction Generator (권선형유도발전기를 갖는 신재생에너지 시스템을 위한 전압벡터 동기화 기법)

  • Park, Jung-Woo;Lee, Ki-Wook;Kim, Dong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.547-555
    • /
    • 2007
  • In order to transmit energy generated through the stator winding of a doubly-fed induction generator (DFIG), we need to synchronize the generated voltage vector with the grid voltage vector. However, the existing synchronization methods work only when the encoder is installed at a specific position and equivalent constant is precise. In order to solve this problem, a new synchronization method has been proposed and a way of applying the method to existing doubly-fed induction generator control algorithm has been also proposed. The validities of the methods proposed were verified by using a prototype converter for a 1.5MW-class doubly-fed induction generator and experimental results showed the validity of that against variation of an encoder positions, generator parameters, and grid voltages.

A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method (Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성)

  • Joung, Jong-Han;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF

Steam Generator Modeling for CANDU Transient Simulation (CANDU 시뮬레이션을 위한 증기발생기 모델링)

  • Seung, Seo-Jae;Cheon, Im-Jae;Park, Ji-Won;Sik, Jeong-U
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.05a
    • /
    • pp.138-143
    • /
    • 1994
  • A simplified steam generator model has been developed for the simulation of the operational transients of CANDU nuclear power plant. For the analysis of the secondary side, a control volume approach is used and the flow conservation equations are applied for each control volume. The typical steam generator control logic such as the level control and the pressure control are incorporated into the steam generator model with appropriate interface conditions. The steam line including ASDV, CSDV, and governor valve also has been modeled. Test results for typical operational transient case show reasonable transient behavior of steam generator in a real time basis, which is promising for a CANDU engineering simulator.

  • PDF

Analysis of Steady and Transient-State Characteristics of Axial-Flux Permanent-Magnet Wind-Turbine Generator (횡자속형 영구자석 풍력발전기의 정상 및 과도상태 특성해석)

  • Hwang D. H.;Kang D. H.;Kim Y. J.;Choi K. H.;Bae S. W.;Kim D. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.78-81
    • /
    • 2002
  • The paper discuses characteristics of an axial-flux permanent-magnet generator for a gearless wind energy system which aims to be satisfied with variable operating conditions. Design and construction of an axial-flux permanent- magnet generator with power output at 60[Hz], 300[r/min] for wind energy system is introduced. Finite-element method (FEM) is applied to analyze generator performance at variable load. The results of FE analysis show this generator Is feasible for use with a wind turbine.

  • PDF

A Selection of an Optimal Mother Wavelet for Stator Fault Detection of AC Generator (교류 발전기 고정자 사고 검출을 위한 최적 마더 웨이브릿의 선정)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.377-382
    • /
    • 2008
  • For stator winding protection of AC generator, KCL(Kirchhoff's Current Law) is widely applied. Actually a CRDR(Current Ratio Differential Relay) based on DFT(Discrete Fourier Transform) has been used for protecting generator. It has been pointed out that defects can occur during the process of transforming a time domain signal into a frequency domain one which can lead to loss of time domain information. Wavelets techniques are proposed for the analysis of power system transients. This paper introduces an algorithm to choose a suitable Mother Wave1et for generator stator fault detection. For optimal selection, we analyzed db(Daubechies), sym(Symlets), and coif(Coiflects) of Mother Wavelet. And we compared with performance of the choice algorithm using detail coefficients energy and RMS(root mean square) error. It can be improved the reliability of the conventional DFT based CRDR. The feasibility and effectiveness of the proposed scheme is proved with simulation using collected data obtained from ATP (Alternative Transient Program) package.

Improvement of Steam Generator Model for DSNP with Two-Region Tube Bundle Model for CANDU Transient Simulation (2영역 튜브모텔을 고려한 CANDU 시뮬레이션용 DSNP 증기발생기 모델 개선)

  • Cheon, Im-Jae;Seung, Seo-Jae
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1994.11a
    • /
    • pp.135-140
    • /
    • 1994
  • An improved steam generator model has been developed for the DSNP simulation of normal operational transient behavior of CANDU nuclear power plant. For more realistic prediction of steam generator behavior during transient, tube bundle region is divided into two separate control volumes, subcooled region and saturated region, and the variation of thermal hydraulic properties in the control volume is accounted for more realistic estimates of outlet enthalpy of each control volume. Test results for typical CANDU operational transient case show reasonable transient behavior of steam generator with overall CANDU operation and improved operational characteristics of steam generator with power variation.

  • PDF

Development of a Nuclear Steam Generator Tube Inspection/maintenance Robot

  • Shin, Ho-Cheol;Kim, Seung-Ho;Seo, Yong-Chil;Jung, Kyung-Min;Jung, Seung-Ho;Choi, Chang-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2508-2513
    • /
    • 2003
  • This paper presents a nuclear steam generator tube inspection/maintenance robot system. The robot assists in automatic non-destructive testing and the repair of nuclear steam generator tubes welded into a thick tube sheet that caps a hemispherical or quarter-sphere plenum which is a high-radiation area. For easy carriage and installation, the robot system consists of three separable parts: a manipulator, a water-chamber entering and leaving device for the manipulator and a manipulator base pose adjusting device. A software program to control and manage the robotic system has been developed on the NT based OS to increase the usability. The software program provides a robot installation function, a robot calibration function, a managing and arranging function for the eddy-current test, a real time 3-D graphic simulation function which offers remote reality to operators and so on. The image information acquired from the camera attached to the end-effecter is used to calibrate the end-effecter pose error and the time-delayed control algorithm is applied to calculate the optimal PID gain of the position controller. The developed robotic system has been tested in the Ulchin NPP type steam generator mockup in a laboratory.

  • PDF

Development of a thermal-hydraulic analysis code for once-through steam generators using straight tubes for SMRs (일체형 원자로용 관류식 직관형 증기발생기 열수력 해석 코드 개발)

  • Park, Youngjae;Kim, Iljin;Kang, Kyungjun;Kang, Hanok;Kim, Youngin;Kim, Hyungdae
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.91-102
    • /
    • 2015
  • A thermal-hydraulic design and performance analysis computer code for a once-through steam generator using straight tubes is developed. To benchmark the developed physical models and computer code, an once-through steam generator developed by other designer is simulated and the calculated results are compared with the design data. Also, the same steam generator is analyzed with the best-estimate thermal-hydraulic system code, MARS, for the code-to-code validation. The overall characteristics of heat transfer area, pressure and temperature distributions calculated by the developed code show general agreements with the published design data as well as the analysis results of MARS. It is demonstrated that the developed code can be utilized for diverse purposes, such as, sensitivity analyses and optimum thermal design of a once-through steam generator.

Heat Transfer and Radiation Shielding Analysis for Optimal Design of Radioisotope Thermoelectric Generator (방사성동위원소 열전 발전기 최적설계를 위한 차폐 및 열전달 해석)

  • Son, Kwang Jae;Hong, Jintae;Yang, Young Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.12
    • /
    • pp.1567-1572
    • /
    • 2013
  • To supply electric power in certain extreme environments such as a spacecraft or in military applications, a radioisotope thermoelectric generator has been highlighted as a useful energy source owing to its high energy density, long lifetime, and high reliability. A radioisotope thermoelectric generator generates electric power by using the heat energy converted from the radioactive energy of a radioisotope. In this study, FE analyses such as radiation shield analysis, heat transfer analysis, and power recovery rate analysis have been carried out to achieve an optimal design for a radioisotope thermoelectric generator using $SrTiO_2$.

A Basic Experimental Study on Vibration Power Generator for A Green Traffic Network (녹색교통망을 위한 진동력 발전 기초 실험연구)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Young-Ji;Park, Jung-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.6D
    • /
    • pp.675-683
    • /
    • 2009
  • A Basic experimental study for the development of vibration-power generation system from the vibration energy of urban infrastructure, such as a railroad, highway, and bridges, was carried out to harvest electricity from moving vehicles. Starting with the proposal of vibration power generator which converts vibration energy to an electric power by using self-induction technology, the research explains the basic concept of self-induction technology and the dynamic characteristics of a ibration power generator. Also, in order to analyze the correlation of an electromotive force from vibration power generator which depends on external force and vibration speeds, many indoor experiments with various variables were achieved. Based on the experimental results, a vibration power generator system's ability were analyzed. With those results, basic data of vibration power generator system to acquire the maximum available power was confirmed.