연축전지와 리튬이온전지용 하이브리드 ESS의 최적구성방안에 관한 연구 (A Study on Estimation Method for Optimal Composition Rate of Hybrid ESS Using Lead-acid and Lithium-ion Batteries)

  • 박수영;유상원;박재범;김병기;김미영;노대석
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.962-968
    • /
    • 2016
  • The large scaled lead-acid battery is widely used for efficient operation of the photovoltaic system in many islands. However, lithium-ion battery is now being introduced to mitigate the fluctuation of wind power and to replace lead-acid battery. Therefore, hybrid ESS(Energy Storage system) that combines lithium-ion battery with lead-acid battery is being required because lithium-ion battery is costly in present stage. Under this circumstance, this paper presents the optimal algorithm to create composition rate of hybrid ESS by considering fixed and variable costs in order to maximize advantage of each battery. With minimization of total cost including fixed and variable costs, the optimal composition rate can be calculated based on the various scenarios such as load variation, life cycle and cost trend. From simulation results, it is confirmed that the proposed algorithms are an effective tool to produce a optimal composition rate.

수리시설의 효율적인 운영 및 관리를 위한 저수지 사통수문개발 (Development of Reservoir's gate for efficient operation and control of facilities)

  • 정광근;이광야;김해도
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.388-392
    • /
    • 2007
  • 지구온단화와 이상기후에 의해 시설물 피해가 나날이 증가하고 있으며, 농촌의 인구감소 및 고령화에 의해 이러한 집중강우등에 대한 대처도 어려운 실정이다. 현재 전국에서 농업용수 공급을 위해 사용하고 있는 농업용 저수지는 17,882개소로서 이 중 축조한지가 35년 이상 경과된 저수지가 15,856개소로서 88.7%나 차지하고 있다. 이러한 현상은 저수지를 구성하고 있는 각종 부대시설의 노후화로 귀결되며 농업용수의 낭비 및 효율적인 운영을 위해서는 시설의 현대화가 필수적이라고 할 수 있다. 따라서 본 연구에서는 저수지에서 물을 직접 공급하는 시설인 사통수문을 대상으로 현대화를 이룩하고 또한 사용동력도 대체에너지를 이용하기 위한 방안을 제시하였다. 사통수문의 수문비는 수중의 압력을 효율적으로 분산시킬 수 있는 원형수문비와 수중에서도 사용동력을 가장 적게 할 수 있는 밸브형을 기준으로 개발을 하였으며, 수문비와 구동부를 연결하는 작동 롯드의 힘전달을 최소화하기 위하여 유니버셜 쪼인트를 볼밸브형으로 개발하였다. 이에 따라서 작동용 롯드의 길이가 길어져도 수문비에 걸리는 작동모멘트를 최소화하여 태양광을 이용한 동력사용이 가능해졌다. 특히 수중에서 움직이는 특성을 감안하여 원형 수문비의 경우에는 수문비와 수문틀 사이에 마찰력을 감소시키기 위하여 수문틀측을 약간 경사지게 가공을 하고 중간에 볼 베이렁을 부착시켜 수문개폐가 원활토록 지수부의 구조변화를 하였다. 또한 농업용수공급시 수류와 함께 유입되는 저수지 내 오물을 차단하기 위하여 수문의 전면에 스크린을 설치하였으며 토사퇴적으로 인하여 수문작동의 방해가 되지 않도록 하기 위하여 토목구조물을 설치하였다. 그리고 동력전달을 효율적으로 하기 위하여 Solar Unit으로부터 나오는 전기를 중전기에서 밧데리로 축전을 시키고 완전 충전 후에는 나머지 전기는 방전이 되도록 회로를 구성하였다. 사통수문 자원조사 결과에 의하면 현재 저수지에 물공급을 하는 수문은 취수탑 형식이 70% 이상을 차지하고 있으며 나머지 30%의 사통수문 중 원형수문비가 98% 이상을 차지하고 있다. 현재 대체에너지를 사용하는 저수지 사통수문은 없는 것으로 조사되었으며 전력을 사용하는 사통도 조사결과에 의하면 20% 이내로 나타났다. 이러한 결과는 향후 수리시설 개보수시 적은 예산으로 사업을 시행하는 경우 사통수문의 설치방향의 지표가 될 것으로 판단되며 수리시설의 운영관리에 대한 새로운 대안으로 제시할 수 있다.

  • PDF

Parallel Genetic Algorithm-Tabu Search Using PC Cluster System for Optimal Reconfiguration of Distribution Systems

  • Mun Kyeong-Jun;Lee Hwa-Seok;Park June-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.116-124
    • /
    • 2005
  • This paper presents an application of the parallel Genetic Algorithm-Tabu Search (GA- TS) algorithm, and that is to search for an optimal solution of a reconfiguration in distribution systems. The aim of the reconfiguration of distribution systems is to determine the appropriate switch position to be opened for loss minimization in radial distribution systems, which is a discrete optimization problem. This problem has many constraints and it is very difficult to solve the optimal switch position because of its numerous local minima. This paper develops a parallel GA- TS algorithm for the reconfiguration of distribution systems. In parallel GA-TS, GA operators are executed for each processor. To prevent solution of low fitness from appearing in the next generation, strings below the average fitness are saved in the tabu list. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper 10$\%$ of the population to enhance the local searching capabilities. With migration operation, the best string of each node is transferred to the neighboring node after predetermined iterations are executed. For parallel computing, we developed a PC-cluster system consisting of 8 PCs. Each PC employs the 2 GHz Pentium IV CPU and is connected with others through switch based rapid Ethernet. To demonstrate the usefulness of the proposed method, the developed algorithm was tested and is compared to a distribution system in the reference paper From the simulation results, we can find that the proposed algorithm is efficient and robust for the reconfiguration of distribution system in terms of the solution quality, speedup, efficiency, and computation time.

시그마 델타 변조에 의한 LED 드라이버의 입력 콘트롤러 설계 (Delta Sigma Modulation of Controller Input Signal for the LED Light Driver)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권2호
    • /
    • pp.151-155
    • /
    • 2016
  • 우리는 이 논문에서 ADPCM (adaptive differential pulse code modulation)을 적용함으로써 디밍 콘트롤러를 갖는 LED 드라이버의 설계를 제시한다. ADPCM 장비는 고해상도를 가지고 LED 전류를 정확하게 제어하며, 고조파 전류 펄스의 퍼짐으로 인하여 초래되는 RFI 를 감소시켜 준다. 또한 제어 동작의 정밀도를 높여준다. 이 연구에서 LED에 펄스 전류를 인가함으로써 고효율 에너지의 LED를 제어하는 디지털 제어회로의 설계를 제시한다. 우리가 설계한 LED 전류구동시스템은 디지털 제어 부와 아날로그 SMPS (스위치 모드 파워 서플라이)를 별도로 구현한 두개의 시스템이다. 입력레벨이 0.7 인 경우의 시뮬레이션 결과는 시그마 델타 변조를 하여 얻은 D/A 컨버터의 출력을 나타내었다. 개수가 510 개인 펄스신호의 경우 0.15 % 의 정밀도를 얻을 수 있었다.

무선 메쉬 네트워크를 위한 캐시 적중률 기반 파워 소모 모델 (A Cache Hit Ratio based Power Consumption Model for Wireless Mesh Networks)

  • 전승현;서용준
    • 산업융합연구
    • /
    • 제18권2호
    • /
    • pp.69-75
    • /
    • 2020
  • 산업용 IoT는 비용 효율적이고 넓은 커버리지를 제공하는 무선 메쉬 네트워크에 관심이 많았다. 하지만, 무선 메쉬 네트워크는 멀티홉 환경의 심각한 성능 절하를 겪는다. 이를 극복하기 위해 메쉬 라우터에 캐시를 장착하는 연구가 많았으나 캐시 파워 소모 모델 연구는 적었다. 최근 캐시 파워 효율 기반 모델은 캐시까지 콘텐츠 전달 파워를 모두 측정했기 때문에 무선 메쉬 네트워크에서 쓰기에 부적절합니다. 본 논문은 CPU의 동작속도가 캐시 크기에 비례한다는 사실을 이용하여 캐시 적중률 기반 파워 소모 모델을 제안하고, 기존 캐시 파워 효율 기반 소모 모델과 비교하여 정확하게 측정되었다. 제안된 캐시 적중률 기반 파워 소모 모델은 산업용 IoT에서 무선 메쉬 네트워크를 구성할 시 에너지 효율적인 캐시 운용을 위한 참조 모델로 활용되길 기대합니다.

중앙난방방식을 지역난방과 소형열병합난방 방식으로 전환 시 경제성 비교 분석 (Analysis of the Economic Efficiency of the District Heating and Gas Engine Co-Generation System Compared with the Central Heating System)

  • 김규생
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.544-551
    • /
    • 2015
  • This study was conducted to determine the LCC of apartment complexes with district heating and a cogeneration system. For the purpose of analyzing LCC according to the size of the apartment complex, 500, 1,500, and 4,000-unit model apartments were selected. Analysis was performed on the design of the heating system and the life cycle cost including total construction cost, maintenance and operation cost for the duration of the project period (15 years). According to the calculated results, 1) The initial cost of the cogeneration system for 500, 1,500, and 4,000-unit apartments is higher than that of the district heating system by 20%, 13%, and 12%, respectively. 2) In the case of the cogeneration system, the payback period by electric generation was found to be 5.21, 4.92 and 4.47 years, and saving cost was calculated to be 29 billion won, 94 billion won and 262 billion won after the payback period for 500, 1,500, and 4,000-unit apartments, respectively. 3) The LCC values of the cogeneration system were 1.12, 1.07 and 1.06 times larger than those of the district system according to the size of the apartment complex. In this study, the district heating system was found to be more efficient than the cogeneration system in terms of LCC reduction. 4) District heating is affected by fuel bills, so energy efficiency should be improved through recovering waste heat (incineration heat, etc.). Also, district cooling should be provided according to heat use to keep the temperature high in winter and low in summer.

고농도 입자성 유기폐수의 고효율 혐기성 소화 공정 (Efficient Anaerobic Digestion for Highly Concentrated Particulate Organic Wastewater)

  • 이성범;신규철;김희주;김현주;최창규;김문일
    • 한국지반환경공학회 논문집
    • /
    • 제9권2호
    • /
    • pp.23-29
    • /
    • 2008
  • 고농도 입자성 유기 폐수를 대상으로 기존 혐기성 공정인 CSTR과 UASB공정으로 처리 시 불량한 상징수질, 불안정한 운전 특성과 같은 문제점이 제시되었다. 이에 본 연구는 새로운 개념의 ADEPT(Anaerobic Digestion Elutriated Phased Treatment) 공정을 주정폐수에 적용하여 처리 가능성을 평가하였다. CSTR과 ADEPT의 성능 비교 결과 ADEPT공정에서 gas 발생량은 약 2배였으며, 유기물 제거 효율과 고형물 제거 효율 역시 더 높은 효율을 보여주었다. 또한 ADPET는 비교적 짧은 HRT에서도 휘발성 지방산 생성으로 인한 pH 저하의 영향을 받지 않았으며, 안정적으로 pH를 유지하였다. ADEPT의 recycle ratio를 6Qin과 2Qin으로 변화를 주어 운전 시 6Qin의 운전 기간 동안 높은 처리 효율을 보여주었다. 따라서 ADEPT는 짧은 HRT로 인한 경제성 향상과 메탄 발생을 이용한 에너지 회수, 또한 산 생성조에서 생성되는 유기산을 최대로 생산, BNR 공정의 유기 탄소원으로 활용 가치가 있다고 판단된다.

  • PDF

지능형 선박의 효울적인 전력사용을 위한 전력 관리 시스템 개발 (Development of a Power Management System for Efficient Power usage of Intelligent Ship)

  • 박지상;전민호;이명의
    • 한국항행학회논문지
    • /
    • 제17권6호
    • /
    • pp.609-615
    • /
    • 2013
  • 어떤 선박에서도 마찬가지로 적정한 전력의 공급은 매우 중요하며, 육지와 거리가 먼 대양 운항 선박에서는 특히 더욱 중요하다. 이와 같이 운항 중인 선박의 전력 공급 시스템의 효율성과 경제성 측면의 문제를 해결하기 위해서 본 논문에서는 선박에서의 전력공급을 지능적으로 제어하는 전력관리 시스템을 제안한다. 본 설계에서의 전력관리 시스템은 부하전력 감지 시스템, 발전기 제어 시스템, 그리고 전력 모니터링 시스템으로 각각 구성된다. 부하전력 감지 시스템에서는 CT 및 PT 센서를 이용하여 전류와 전력량을 측정하며, 그리고 발전기 제어 시스템에서는 여러 가지 다양한 센서로 부터의 취합정보를 이용하여 주/부 발전기를 On/Off 하게 된다. 마지막으로 모니터링 시스템은 부하 전력 감지 시스템과 발전기 관리 시스템에서 수집된 정보를 사용자가 한눈에 알아볼 수 있게 상태 정보를 출력한다. 본 논문에서 구현된 전력관리 시스템은 실시간 실험을 통해서 설계된 바와 같이 잘 작동하는 것을 확인하였으며, 그리고 공인 인증기관으로부터 KSCIEC61892-1:2012 및 KSCIEC60950-1:2008 인증을 획득하였다.

ML 기반의 전기추진시스템을 위한 PCS에 관한 연구 (A Study on PCS for ML-Based Electrical Propulsion System)

  • 이종학;이헌석;오진석
    • 한국정보통신학회논문지
    • /
    • 제23권9호
    • /
    • pp.1025-1031
    • /
    • 2019
  • 본 연구는 선박용 해수펌프를 ML 기반으로 한 알고리즘을 구현하여 효율적으로 운용할 수 있는 PCS를 제안한다. PCS가 탑재된 2척의 선박에서 해수온도, RPM, 전력 소모 데이터를 취득하여 회귀 분석법으로 분석하고, 새로운 알고리즘을 제시한다. 제시하는 알고리즘을 적용하였을 때 Ship A는 PCS를 적용하지 않았을 때 대비하여 약 36%를 절감하였고, 특정 해역온도인 $19{\sim}27^{\circ}C$$32^{\circ}C$ 이상의 해역에서 ML 기반의 알고리즘이 Ship A의 PCS보다 약 1% 더 절감하였다. Ship B는 PCS를 적용하지 않았을 때 대비하여 약 50%를 절감하였고, 특정 해역온도인 $19^{\circ}C$ 이상의 해역에서 Ship B의 PCS보다 약 2%더 절감하였다. 도출된 데이터를 이용하여 최적의 펌프 속도와 항로를 제안할 수 있다. 추가적으로, 취득 데이터의 추세를 활용하여 효율이 낮아졌을 시에 펌프의 성능이나 MGPS의 소제 시기를 유추할 수 있다.

Direct Harmonic Voltage Control Strategy of Shunt Active Power Filters Suitable for Microgrid Applications

  • Munir, Hafiz Mudassir;Zou, Jianxiao;Xie, Chuan;Li, Kay;Younas, Talha;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.265-277
    • /
    • 2019
  • The application of shunt active power filters (S-APFs) is considered to be the most popular approach for harmonic compensation due to its high simplicity, ease of installation and efficient control. Its functionality mainly depends upon the rapidness and precision of its internally built control algorithms. A S-APF is generally operated in the current controlled mode (CCM) with the detection of harmonic load current. Its operation may not be appropriate for the distributed power generation system (DPGS) due to the wide dispersion of nonlinear loads. Despite the fact that the voltage detection based resistive-APF (R-APF) appears to be more appropriate for use in the DPGS, the R-APF experiences poor performance in terms of mitigating harmonics and parameter tuning. Therefore, this paper introduces a direct harmonic voltage detection based control approach for the S-APF that does not need a remote harmonic load current since it only requires a local point of common coupling (PCC) voltage for the detection of harmonics. The complete design procedure of the proposed control approach is presented. In addition, experimental results are given in detail to validate the performance and superiority of the proposed method over the conventional R-APF control. Thus, the outcomes of this study approve the predominance of the discussed strategy.