• 제목/요약/키워드: Energy efficiency grade

검색결과 104건 처리시간 0.027초

초지기 자동화 해법에 의한 운전비용 절감대책 (Cost savings for paper machines with automation solution packages)

  • Sorsa, Jukka
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2007년도 제32회 펄프종이기술 국제세미나
    • /
    • pp.83-125
    • /
    • 2007
  • Increasing energy costs have caused profitability problems for paper suppliers. Therefore unprofitable lines are being closed down. The actions aiming for improved profits are focused either on cost savings or on increasing the capacity of the remaining machines. The runnability of a paper machine and its total efficiency have a significant effect on energy consumption. Producing one ton of waste paper consumes at least as much energy as producing the same amount of sellable end product. New automation solutions enable significant cost-effective improvements to the total efficiency of a line without large investment projects. The measures focus on minimizing changes, interruptions, interruption recovery times and grade change times. Newest actuators, online quality measurements and wet end analysators create an improvement potential, which can be optimally implemented with the latest machine direction control solutions, based on model predictive control concepts. Equally, drying management is significant to the energy consumption. The newest control strategies optimize the use of various drying actuators for different situations; either by responding to changes as efficiently as possible or by using only the cheapest energy sources in stable situations. An even steam supply, which is vital for paper machines, is achieved with control for the power plant steam network. This makes possible to avoid the delays upon starting the paper machine and assure an even steam supply for the drying section and the actuators. This document describes means which have brought significant energy and raw material savings for paper machines. Metso Automation has provided efficiency improvement packages, which are usually based on optimized control of dry weight and drying in all running conditions. The solutions are based on performance analysis, on which the estimations for improvement potential and the necessary actions are based on. Typically benefits on an annual level have been from hundreds of thousands of euros to over one million euro. For example, variations in dry weight have been decreased more than 50%. The results are presented with a few examples. Additionally, the analysis models, adjustment solutions and the changes in running methods with which the results were achieved, are presented.

  • PDF

강유전체 세라믹스를 이용한 전자식 안정기용 절전모듈 (Power-saving Module using Ferroelectric Ceramics for Electronic Ballast)

  • 신현용
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권5호
    • /
    • pp.741-748
    • /
    • 2005
  • 형광램프용 전자식 안정기의 효율개선 및 램프의 수명연장을 위하여 강유전체 커패시터와 시간지연스위칭회로로 구성된 절전모듈을 개발하고 적용하였다. 절전모듈에 사용된 강유전체 세라믹스를 이용하여 형광램프의 부저항특성과 최적화를 시키고, 시간지연회로를 통하여 점등초기 예열형에서 비예열형으로 스위칭시켜 점등 중 필라멘트에서 소비되는 전력을 제거함으로써 약 2W의 소비전력을 감소시켜 효율개선을 실현하였으며, 역기전력 제거기능을 통하여 점등 초기 형광램프 필라멘트에 가해지는 충격을 최소화함으로써 형광램프의 수명을 연장시켰다.

  • PDF

G-SEED 인증 건축물과 비인증 건축물의 에너지 소비량 특성에 관한 연구 : 업무시설을 대상으로 (A Study on the Comparison for Energy Consumption Characteristics between G-SEED certified and non-certified Office Buildings in Korea)

  • 김종현;김진호
    • 한국산학기술학회논문지
    • /
    • 제20권11호
    • /
    • pp.33-43
    • /
    • 2019
  • 기후변화 문제를 해결하기 위해 세계 각국은 온실가스 감축 의무를 이행하기 위해 노력하고 있다. 건물부문은 국가 온실가스 배출량의 약 25%를 차지하며, 향후 40%까지 증가할 것으로 전망하는 만큼 정부는 에너지 절감 계획에 대한 정책을 수립하여 추진 중이다. 건물부문의 에너지 절감을 위한 정책의 일환으로 녹색건축인증제도 시행을 통해 보다 에너지 절감형 건축물 설계와 시공을 유도하고 있다. 본 연구는 G-SEED 인증 건축물과 비인증 건축물의 에너지 소비량에 영향을 미치는 원인에 대한 분석과 결과를 바탕으로 현행 제도의 실효성과 문제점을 파악하고 향후 G-SEED 제도의 개선 방향에 대해 논의하고자 한다. 이를 위해 서울시에 소재하고 있는 인증 업무시설 135동과 비인증 업무시설 142동을 대상으로 건축물 정보와 에너지 소비량 데이터를 수집하였으며, 분석결과 다음과 같은 결론을 도출하였다. 인증 업무시설은 비인증 업무시설에 비해 연간 50% 이상의 에너지 절감효과가 있는 것으로 나타났다. 계절에 따른 에너지 소비량은 난방 도일과 높은 상관관계가 있는 것으로 나타났다. 사용승인연도가 높을수록 인증 업무시설의 에너지 소비량은 감소하며, 비인증 업무시설은 오히려 증가하는 경향을 보였다. 규모와 인증등급에 따른 에너지 소비량은 상관관계가 미미한 것으로 드러났다. 본 연구는 이상의 분석을 통하여 G-SEED 인증제도 개선을 위한 기초자료로서 의의가 있다. 또한 건축물의 에너지성능 기준이 강화되는 추세를 감안하여, 분야별 점수를 공개적인 자료로 전환하는 것을 제시한다.

공동주택 제로에너지빌딩 인증을 위한 적정가산비 산정에 관한 연구 (A Study on the Estimation of Additional Cost for the Certification of Zero Energy Apartment Buildings)

  • 사용기;한찬훈
    • 한국건설관리학회논문집
    • /
    • 제20권5호
    • /
    • pp.21-30
    • /
    • 2019
  • 최근 전 세계적으로 지구온난화에 따른 이상기온과 화석연료 고갈 등 환경과 에너지문제는 인류의 생존을 위협하는 중대 과제로 대두되고 있다. 이에 따라 건축물 에너지 절감 및 온실가스 감축에 획기적으로 기여할 수 있는 혁신적인 건축물로서 제로에너지빌딩에 대한 관심이 높아지고 있다. 그러나 시장에서는 추가되는 건설비용은 제로에너지 인증 활성화에 큰 걸림돌이 되고 있다. 본 연구에서는 일반적인 민간 분양아파트를 연구의 대상으로 선정하고 초기 설계단계부터 제로에너지 인증을 위한 세부 요소들을 친환경주택 건설기준에 근거하여 제시하였으며, 인증 세부요소들의 비용효율분석을 통해 적정 가산비용을 제시하였다. 아직까지 기술수준과 물리적인 한계로 인하여 공동주택에서는 3등급까지만 인증이 구현 가능 한 것으로 분석되었다. 또한 생애주기동안 비용추이를 검토해본 결과 아직까지 제로에너지빌딩 5등급의 경우에서만 준공 후 13년 이내 모든 비용의 회수가 가능한 것으로 검토되었다. 앞으로 발주예정인 공동주택 사업 검토 시 본 연구에서 제시된 추가사업비가 적절히 반영되어 제로에너지빌딩 인증 활성화에 기여하고자 한다.

유기랭킨사이클의 작동유체 물성치가 사이클에 미치는 영향에 관한 연구 (Effect on the Cycle by the Properties of Working Fluids Using Organic Rankine Cycle)

  • 조수용;조종현
    • 한국유체기계학회 논문집
    • /
    • 제18권4호
    • /
    • pp.5-12
    • /
    • 2015
  • Several working fluids for Organic Rankine Cycle(ORC) were recommended by many researchers. However, the recommended optimal working fluids were not exactly same because the operating conditions of ORC and application were different. The major parameter to select the working fluid for ORC was the temperature of available thermal energy. In this study, low-grade thermal energy was used for the heat source for ORC and the appropriate working fluids were searched among 26 candidate working fluids. The requirements to be a working fluid for ORC were reviewed and the cycle analysis for simple cycle was conducted with $75^{\circ}C$ and $35^{\circ}C$ at the turbine inlet and exit, respectively. R600, R601, toluene were best candidates if the system could work without leaking the working fluid. Next, R236ea, R245ca, R245fa were recommended because they are not inflammable working fluids as well as better efficiency.

물 대 물 방식 수직 밀폐루프 지열원 히트펌프 시스템의 냉방성능에 대한 실험적 연구 (Experimental Study on the Cooling Performance of Vertical Closed Loop Water to Water Ground Source Heat Pump System)

  • 홍부표;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.58-63
    • /
    • 2014
  • A vertical closed loop ground source heat pump (GSHP) is used to produce heat from the low-grade energy source such as the outside air and ground source. It is known that a heat pump system type has better efficiency comparing to the electric heating system. This study only demonstrates that the vertical closed loop GSHP system is a feasible choice for space cooling of air conditioning. The coefficient of performance (COP) is the ratio of heat output to work supplied to the system in the form of electricity. For the vertical closed loop GSHP system in a cooling mode, the COP is the most commonly used way for judging the efficiency. For the purpose of this experiment, vertical closed loop GSHP system was installed in the laboratory and the experiment was executed. As a result, an average COP of vertical-closed loop GSHP system was 3.62 when the outside average temperature was $33^{\circ}C$.

난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토 (A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio)

  • 서준선;김영직;박준규;이창언
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

ZEB 활성화를 위한 부하기준 산정 방법 연구 (A Study on the Calculation Method of Load standard for ZEB activation)

  • 이항주;김인수
    • 에너지공학
    • /
    • 제26권4호
    • /
    • pp.92-99
    • /
    • 2017
  • 국내에서는 국토부 7대 신산업, 산업부 8대 신산업으로 제로에너지빌딩이 지정되었으며, 건물외피의 단열성능 극대화와 건물 기기 효율향상 및 신재생 보급 확대를 위해 부처간 융합을 통해 제로에너지빌딩 보급 활성화 달성을 목표로 하고 있다. 국내에서 시행 중인 제로에너지빌딩 인증제에 해당되는 건물에너지효율등급 1++이상이 되는 건축물들의 부하(냉방, 난방, 급탕, 조명, 환기)들의 에너지소요량을 분석하여 대략적인 부하들의 수준을 파악하고 제로에너지빌딩 인증제 고도화를 위한 기초 자료로 활용될 수 있도록 하는 목적이 있다. 제로에너지빌딩 인증에 해당되는 건축물은 2017년 기준 61개 가량 되는 것으로 파악되고 있으며, 패시브 측면과 액티브 측면을 고려하여 5대 부하별 대략적인 기준 값과 1차 에너지소요량을 산정하였다. 부하기준 산정을 위한 데이터의 표본이 적어 명확한 기준이 된다고 보기는 어려우나 앞으로 제로에너지빌딩 인증 기준을 고도화하기 위해 다양한 방법들을 적용하여 해석할 필요성이 있다고 판단된다.

서울시 햇빛지도 기반의 RPS제도를 고려한 옥상녹화 연계 태양광발전 시스템의 경제성 분석 (Economics Analysis of Photovoltaic Power Generation Linked with Green Roof in Consideration of Seoul Solar Map-based RPS)

  • 김태한;이소담;박정현
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.77-82
    • /
    • 2017
  • In power supply systems for urban areas, issues such as a progressive tax have escalated recently. In this regard, photovoltaic power generation, which is appraised as an alternative power generation system, is drawing attention increasingly for its high stability and applicability to existing infrastructure. This study assessed the realistic feasibility of photovoltaic power generation and also analyzed the economic benefits expected when it is linked with green roof, which is likely to promote ecological functions in urban areas, based on the Seoul solar map, RPS, and actual monitoring data. The economics analysis of 30kW photovoltaic power generation applied with the monthly average horizontal solar radiation of six grades in the Seoul solar map showed that positive NPV was up to grade 4, while grade 5 or poorer showed negative NPV and indicated that it is difficult to assure appropriate feasibility. Compared with non-afforestation, when green roof was applied, monthly average power improvement efficiency was 7.2% at highest and 3.7% at lowest based on yearly actual monitoring data. The annual average was 5.3%, and the efficiency was high relatively in summer, including September and November. As for the economic benefits expected when 30kw photovoltaic power generation is combined with green roof based on the average horizontal solar radiation of grade 1 in the Seoul solar map, SP has improved 0.2 years to 7.4 years, and EP has improved 0.5 years to 8.3 years.

황산화 배소법에 의한 구리성분의 선택적 침출연구 (A Study on the Selective Leaching of the Copper Component by Sulfation Process)

  • 김우진;김준수;김명준;;이진영;신선명
    • 자원리싸이클링
    • /
    • 제25권5호
    • /
    • pp.57-63
    • /
    • 2016
  • 본 연구는 호주산 저품위 동광의 선광실험결과로 얻은 고품위 광물의 황산화 배소 및 선택적 침출반응 조건 확립을 통해 유가 광물 중에 함유된 성분을 선별적으로 용해해냄으로써 철 성분을 비롯한 불순물을 줄이거나, 동 및 니켈 성분을 용해 혹은 잔사에 잔류시킴으로써 유가금속회수를 효과적으로 회수하고자 하는데 목적이 있다. 본 연구실험결과 얻은 최적조건은 황산화 배소시 $450^{\circ}C$, $Na_2SO_4$ 2 mole ratio 및 1.5 h이었고, 배소산물의 침출온도는 상온 및 침출제는 $H_2O$ 혹은 1M $H_2SO_4$이었다. 최적조건 하에서 Cu 성분은 90 wt.% 침출율을 Fe성분은 20 wt.%내외, Ni성분은 15 wt.% 정도를 나타내는 것으로 보아 선택적 분해침출이 가능하다.