• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 863, Processing Time 0.029 seconds

A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System (하이브리드 제습냉방시스템의 성능평가 연구)

  • Hwang, Won-Baek;Kim, Young-Chan;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

Domestic Greenhouse Gas Reduction Policy (국내 온실가스 감축 정책)

  • Bae, Sung-Ho
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.8-12
    • /
    • 2011
  • For reducing greenhouse gas emissions, the short-term strategy is of existing energy-efficient appliances to facilitate the spread of energy efficiency improvements to improve energy efficiency, energy saving projects that will include investments to enable. R&D is at the core of the long-term strategy. To reduce energy demand, the equipments and processes improved energy efficiency should be developed. In terms of energy supply, the policies for greenhouse gas reduction is to replace fossil fuels by expanding the supply of renewable energy such as solar, wind, geothermal, biomass and nuclear power as nearly zero-emission of greenhouse gas. In terms of energy consumption, measures to reduce greenhouse gas emissions is in line with the policy for efficiency improvement. The buildings & work-site of high-energy consumption in the building & Industry sectors, should implement a policy to strengthening the voluntary agreement on energy-saving facilities and expand to invest in energy saving facilities.

NEUTRON INDUCED CROSS SECTION DATA FOR IR-191 AND IR-193

  • Lee, Yong-Deok;Lee, Young-Ouk
    • Nuclear Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.803-808
    • /
    • 2006
  • The neutron induced nuclear cross section data for Ir-191 and Ir-193 were calculated and evaluated from unresolved resonance energy to 20MeV. The energy-dependent optical model potential parameters were determined based on the experimental data and applied up to 20MeV. A spherical optical model, a statistical model in an equilibrium energy region, and a multistep direct and multistep compound model in a pre-equilibrium energy region were used in the calculations. The direct capture model enhanced the fast neutron capture in the pre-equilibrium energy. The theoretically calculated cross sections were compared with the experimental data and the evaluated files. The calculations were found to be in good agreement with the experiment data. The evaluated cross section results were compiled with the ENDF-6 format. The fast energy results will be merged with the resonance parts to create a full evaluation library. The improvement of the neutron-induced cross section data will contribute to an increase in the efficiency of the production of Ir-192 as a radiation source.

A Direction of Energy Rating System for Existing buildings (기존 건축물 에너지 성능 개선 제도의 방향성 제안)

  • Hong, Sim-Hee;Lee, Seul-Ki;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.149-150
    • /
    • 2013
  • Energy systems in increasing energy efficiency are actively performed at home and abroad. But Generally systems in the country are limited in a new building or sort of some buildings like a public and office building. So, this research suggest a new direction of energy system for existing buildings. It need to set a new bound for containing the green remodeling. For a direction, we analysis domestic energy system in perform and compared their bounds, standard and methods of energy evaluation. This study is necessary for an additional research for proposing detailed evaluation items and for a feasibility study research. And it contribute to develope internal energy systems and set a new system bound.

  • PDF

A Study on the Environmental Evaluation in Use Stage of KTX and Samaul Train : the Development of Eco-efficiency Indicator (생태효율성(Eco-efficiency)지표 개발을 통한 KTX와 새마을호 열차의 사용단계 환경성 평가에 관한 연구)

  • Choi, Yong-Sin;Chun, Yoon-Young;Lee, Kun-Mo;Kim, Yong-Ki
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1313-1320
    • /
    • 2011
  • World Business Council for Sustainable Development(WBCSD) is effort to achieve sustainable development in economic growth, environmental preservation and social development. Being this way, it is essential for developing evaluation tool which quantify to fulfill sustainable development. Eco-efficiency is one of the quantitative tools to evaluate environmental impact and economic aspect. Eco-efficiency, in general term, means creating more value of product or services with less impact to environment. It indicates as environmental impact in denominator and value of product or services in numerator. Eco-efficiency shows how much economic value reveals to unit environmental impact caused by product or service as an indicator. This study aims at developing eco-efficiency indicator of railway industry considering use stage among the entire life cycle stage of KTX and Saemaul train and also, figure out eco-efficiency value through indicator. Therethrough, it is enables to evaluate created value per environmental aspects. Since rail vehicles demands a lot of energy to transport people during use stage, the environmental impact is more significant than other lkfe cycle stages. Therefore, it quantified environmental indicator as CO2 emission and economic indicator as transportation record per a year with an annual income. This study contributes to be used as a tool for quantifying indicator of comparison evaluation in respect of rail vehicle in use stage.

  • PDF

Evaluation of Energy Savings for Inverter Driving Centrifugal Pump with Duty Cycles (인버터 구동 원심펌프의 급수 사용율에 따른 에너지 절감 평가)

  • Kim, Kyungwuk;Suh, Sang-Ho;Rakibuzzaman, Rakibuzzaman
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.81-85
    • /
    • 2015
  • The purpose of this study is to evaluate energy savings for inverter driving multi-stage centrifugal pump. Variable speed driving pump system has high efficiency compared with constant speed driving pump system. Because of difficulty to estimate operating efficiency of variable speed driving pump system, energy saving rates are used to replace operating efficiency. energy saving rates are calculated from pump input power and pump duty cycle. But another researches have used pump duty cycles of each season for energy saving rate. In this study, for estimating energy saving rate more high accuracy, pump duty cycles are measured for 1 year. pump duty cycles, depending on the season and be classified according to the weekday/weekend or during the week day. By this pump duty cycles, Energy saving rate is calculated appropriately.

Economic Evaluation of Domestic Window Type Photoelectrochemical Hydrogen Production Utilizing Solar Cells (태양전지를 이용한 국내 Window Type 광전기화학 수소생산의 경제성 평가)

  • Gim, Bong-Jin;Kim, Jong-Wook
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.6
    • /
    • pp.595-603
    • /
    • 2010
  • This paper deals with an economic evaluation of domestic window type photoelectrochemical hydrogen production utilizing solar cells. We make some sensitivity analysis of hydrogen production prices by changing the values of input factors such as the initial capital cost, the solar to hydrogen conversion efficiency, and the system duration time. The hydrogen production price of the window type photoelectrochemical system was estimated as 1,168,972 won/$kgH_2$. It is expected that hydrogen production cost can be reduced to 47,601 won/$kgH_2$ if the solar to hydrogen conversion efficiency is increased to 14%, the system duration time is increased to 20,000 hours, and the initial capital cost is decreased to 25% of the current level. We also evaluate the hydrogen production cost of the water electrolysis using the electricity produced by solar cells. The corresponding hydrogen production cost was estimated as 37,838 won/$kgH_2$. The photoelectrochemical hydrogen production is evaluated as uneconomical at this time, and we need to enhance the solar to hydrogen conversion efficiency and the system duration time as well as to reduce prices of the system facilities.

Performance Analysis of Upgrading Process with Amine-Based CO2 Capture Pilot Plant

  • Kwak, No-Sang;Lee, Junghyun;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2018
  • This study applied upgrades to the processes of a 10 MW wet amine $CO_2$ capture pilot plant and conducted performance evaluation. The 10 MW $CO_2$ Capture Pilot Plant is a facility that applies 1/50 of the combustion flue gas produced from a 500 MW coal-fired power plant, and is capable of capturing up to 200 tons of $CO_2$. This study aimed to quantitatively measure efficiency improvements of post-combustion $CO_2$ capture facilities resulting from process upgrades to propose reliable data for the first time in Korea. The key components of the process upgrades involve absorber intercooling, lean/rich amine exchanger efficiency improvements, reboiler steam TVR (Thermal Vapor Recompression), and lean amine MVR (Mechanical Vapor Recompression). The components were sequentially applied to test the energy reduction effect of each component. In addition, the performance evaluation was conducted with the absorber $CO_2$ removal efficiency maintained at the performance evaluation standard value proposed by the IEA-GHG ($CO_2$ removal rate: 90%). The absorbent used in the study was the highly efficient KoSol-5 that was developed by KEPCO (Korea Electric Power Corporation). From the performance evaluation results, it was found that the steam consumption (regeneration energy) for the regeneration of the absorbent decreased by $0.38GJ/tonCO_2$ after applying the process upgrades: from $2.93GJ/ton\;CO_2$ to $2.55GJ/tonCO_2$. This study confirmed the excellent performance of the post-combustion wet $CO_2$ capture process developed by KEPCO Research Institute (KEPRI) within KEPCO, and the process upgrades validated in this study are expected to substantially reduce $CO_2$ capture costs when applied in demonstration $CO_2$ capture plants.

Design and Performance Evaluation of Solar Air Receivers (공기식 태양열 흡수기의 설계 및 성능평가)

  • Cho, Hyun-Seok;Lee, Hyun-Jin;Kim, Jong-Kyu;Lee, Sang-Nam;Kang, Yong-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.207-212
    • /
    • 2012
  • It is important to produce the high-temperature and high-pressure air for the concentrated solar power system using the combined cycle. In this paper, we designed two types of tubular receivers to heat up the compressed air and provided their preliminary experimental results for performance evaluation and further improvements. The developed receivers are in a square cavity shape surrounded by flow conduits for easy scale-up and radiation loss reduction. The two receivers were tested with 5 bar air in the KIER solar furnace and evaluated in terms of the outlet temperature and the efficiency.

Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings (건물에너지 절감을 위한 열차단 필름의 성능 평가)

  • Nam, Jung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF