• Title/Summary/Keyword: Energy efficiency evaluation

Search Result 863, Processing Time 0.029 seconds

Performance Evaluation of a Crank-driven Compressor and Linear Compressor for a Household Refrigerator

  • Park, Minchan;Jung, Yoongho;Lee, Jaeyeol;Lee, Jaekeun;Ahn, Youngchull
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.5-12
    • /
    • 2017
  • With the difficulties in increasing the efficiency of conventional crank-driven compressors due to mechanical loss, compressor manufacturers have investigated new kinds of compressor such as a free piston compressor mechanism. This study investigates the energy efficiency of two different types of compressor for a household refrigerator. One is the conventional crank-driven compressor, and the other one is a linear compressor. The energy efficiencies of these compressors are evaluated. Experimental results show that the linear compressor has 10% lower power consumption than the brushless direct-current (BLDC) reciprocating compressor. The linear compressor demonstrates excellent energy efficiency by reducing the friction loss. Furthermore, a motor efficiency exceeding 90% is achieved by using a linear oscillating mechanism with a moving magnet. Additionally, the compressor stroke to piston diameter ratio of the oscillating piston in the linear compressor can be adjusted in order to modulate the cooling capacity of the compressor for improved system efficiency.

Performance Evaluation of the Samcheonpo Small-Hydro Power Plant (삼천포 해양소수력 성능평가)

  • Cho, Hong-Yeon;Cho, Beom-Jun;Kang, Geum-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.617-620
    • /
    • 2007
  • The performance evaluation of the Samcheonpo small-hydropower plant constructed on the October 25th,2006, was carried out focused on the turbine and generator efficiency analysis by using the measurement data. The unreasonable and unrealistic efficiency results are occurred in some periods because of the data variability, uncertainty, and measurement errors and mistakes. Whereas, the big mismatch is the tidal elevation predicted in the design processes. The difference between the measured and estimated tidal elevation is obvious during the low water period. It should be considered and checked in depth on the efficiency analysis of the planned and constructing small-hydro power plants in other coastal areas.

  • PDF

A New Efficient Mppt Control Algorithm for Low Insolation Intensity

  • Yu, Gwon-Jong;Jung, Young-Seok;Park, Ju-Yeop
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.4
    • /
    • pp.214-218
    • /
    • 2002
  • In this paper, the effectiveness of three different control algorithms are thoroughly investigated via simulation and a proposed efficiency evaluation method of experimentation. Both the steady state and transient characteristics of each control algorithm along with its measured efficiency are analyzed. Finally, a novel two-mode maximum power point tracking (MPPT) control algorithm combining the constant voltage control and the incremental conduction (IncCond) methods is proposed to improve the efficiency of the 3KW PV power generation system at different insolation conditions. Experimental results show that the proposed two-mode MPPT control provides excellent performance at less than 30% insolation intensity, covering the whole insolation area without additional hardware circuitry.

Study on the Evaluation of Regional Building Energy Efficiency Rating According to the Insulation Performance of Double Skin Window in Apartment Houses Expanded Balcony (발코니 확장형 공동주택의 이중외피 창호 열성능에 따른 지역별 건축물에너지 효율등급 평가)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.32-37
    • /
    • 2010
  • In order to handle the crisis about energy-environment problem, it is necessary to develop the future-oriented and innovative energy technology in architecture area. So the development of new technology for energy saving and alternative energy use has been spurred in this area. Double skin window system, which is an active covering to respond to the exterior change of the environment, is the skill that can reduce the indoor cooling and heating load and the environmental architecture can be realized. This study works out U-value of windows using the window-simulation program with the development and study of the double skin. In addition, the effect of the double skin insulation on the efficiency rating has been analyzed, applying to the certification system of the building energy efficiency rating which has implemented.

A study on hybrid solar LED street light system (하이브리드 태양광 LED 가로등 시스템 연구)

  • Lee, Dong-Hyuk
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.20-25
    • /
    • 2022
  • In line with the rapid economic growth of many countries, fossil fuel energy sources are also rapidly depleting. Therefore, the price is also rising rapidly, so it is necessary to develop new and renewable energy sources such as hydropower, geothermal power, nuclear power, wind power and solar energy to replace fossil fuel energy in the future. In this study, development of rotating concentrator module system, development of rotating module control control system, development of lamp and charge control controller, configuration and prototype production of rotating concentrating solar LED street light system, efficiency of rotating concentrating solar LED street light, and power production. The research was conducted in the order of evaluation of comprehensive performance tests such as consumption and consumption. As a result, the developed high-efficiency rotation-concentrating hybrid solar LED street light module system has a 50% higher light-gathering efficiency than existing products by tracing sunlight by self-developing a rotation-collecting module on existing solar LED street lamps according to the characteristics of Korea's topography. and the power generation was improved by more than 40%.

A Study on the Evaluation of Apartment Building Energy Efficiency Rating Considering the Performance of Thermal Insulators and Window glasses (창호 및 단열재 변수에 따른 공동주택 에너지효율등급 평가 사례)

  • Kim, Han-Soo;Yun, Hae-Dong;Byun, Woon-Seob
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.706-711
    • /
    • 2009
  • Energy shortage and environmental pollution caused by fossil fuels are very serious problem. Especially buildings have consumed more and more energy, and buildings are spend up to 25% of total energy consumption. So we should prepare alternatives to save energy in buildings. In apartment houses, The efficiency of thermal insulators and window glasses is very important to curtail heating energy. In this study, the energy rating of Apartment building is evaluated by applying various thermal insulators and window glasses.

  • PDF

A Study on Peak Power Reduction using Regenerative Energy in Railway Systems through DC Subsystem Interconnection

  • Jung, Seungmin;Lee, Hansang;Kim, Kisuk;Jung, Hosung;Kim, Hyungchul;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1070-1077
    • /
    • 2013
  • Owing to the consistent increase in energy efficiency issues, studies for improving regenerative energy utilization have been receiving attention in the Urban DC railway systems, where currently, the utilization of regenerative energy is low due to the lack of a specific plan for using this energy. The regenerative energy in railway systems has a low efficiency problem which results in the increase of the catenary voltage and a possibility to create problems to the electrical devices connected to the system. This paper deals with the power integration of large urban railway subsystems to improve regenerative energy utilization where the railway subsystems are integrated with other railway subsystems to improve the energy efficiency. Through the case studies, to find the realistic effect of integrated operation, the Seoul Metro subsystems, namely Line 5 and Line 7, has been applied. Also, evaluation for the electricity cost saving has been performed by using KEPCO electricity cost table.

A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing (로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jang, Cheol-Yong;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

The Energy Performance & Economy Efficiency Evaluation of Micro Gas Turbine Installed in Hospital (대형병원 건물에 마이크로 가스터빈 적용을 위한 에너지성능 및 경제성 평가)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.8-13
    • /
    • 2009
  • Feasibilities of the application of a micro gas turbine cogeneration system to a large size hospital building are studied by estimating energy demands and supplies. The energy demand for electricity is estimated by surveying and sorting the consumption records for various equipment and devices. The cooling heating, and hot water demands are further refined with TRNSYS and ESP-r to generate load profiles for the subsequent operation simulations. The operation of the suggested cogeneration system in conjunction with the load data is simulated for a time span of a year to predict energy consumption and gain profile. The simulation revealed that the thermal efficiency of the gas turbine is about 30% and it supplies 60% of the electricity required by the building. The recovered heat can meet 56% of total heating load and 67% of cooling, and the combined efficiency reaches up to 70%.