• 제목/요약/키워드: Energy efficiency evaluation

검색결과 864건 처리시간 0.026초

하이브리드 제습냉방시스템의 성능평가 연구 (A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System)

  • 황원백;김용찬;이대영
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

국내 온실가스 감축 정책 (Domestic Greenhouse Gas Reduction Policy)

  • 배성호
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.8-12
    • /
    • 2011
  • 온실가스 감축을 위한 단기 정책으로는 기존의 고효율 에너지 기기의 보급을 촉진하고 에너지 효율을 개선하는 에너지 효율개선, 에너지 절약사업에 투자를 활성화하는 것 등이 포함된다. 장기적으로는 기술개발이 핵심정책이다. 에너지수요의 저감을 위해서는 에너지 효율이 향상된 기기와 공정이 개발되어야 한다. 에너지 공급측면에서 온실가스 감축정책은 태양광, 풍력, 지열, 바이오매스 등과 같은 신재생에너지와 원자력과 같은 온실가스를 거의 배출하지 않는 저배출 에너지원의 공급을 확대하여 화석연료를 대체하는 것이다. 에너지 소비측면에서 온실가스 감축대책은 에너지 효율향상 정책과 맥을 같이 한다. 산업과 건물부문에서 에너지 다소비사업장, 건물 등에 대한 자발적 협약을 강화하고, 에너지 절약시설에 대한 투자를 강화하는 정책을 시행해야 할 것이다.

NEUTRON INDUCED CROSS SECTION DATA FOR IR-191 AND IR-193

  • Lee, Yong-Deok;Lee, Young-Ouk
    • Nuclear Engineering and Technology
    • /
    • 제38권8호
    • /
    • pp.803-808
    • /
    • 2006
  • The neutron induced nuclear cross section data for Ir-191 and Ir-193 were calculated and evaluated from unresolved resonance energy to 20MeV. The energy-dependent optical model potential parameters were determined based on the experimental data and applied up to 20MeV. A spherical optical model, a statistical model in an equilibrium energy region, and a multistep direct and multistep compound model in a pre-equilibrium energy region were used in the calculations. The direct capture model enhanced the fast neutron capture in the pre-equilibrium energy. The theoretically calculated cross sections were compared with the experimental data and the evaluated files. The calculations were found to be in good agreement with the experiment data. The evaluated cross section results were compiled with the ENDF-6 format. The fast energy results will be merged with the resonance parts to create a full evaluation library. The improvement of the neutron-induced cross section data will contribute to an increase in the efficiency of the production of Ir-192 as a radiation source.

기존 건축물 에너지 성능 개선 제도의 방향성 제안 (A Direction of Energy Rating System for Existing buildings)

  • 홍심희;이슬기;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.149-150
    • /
    • 2013
  • Energy systems in increasing energy efficiency are actively performed at home and abroad. But Generally systems in the country are limited in a new building or sort of some buildings like a public and office building. So, this research suggest a new direction of energy system for existing buildings. It need to set a new bound for containing the green remodeling. For a direction, we analysis domestic energy system in perform and compared their bounds, standard and methods of energy evaluation. This study is necessary for an additional research for proposing detailed evaluation items and for a feasibility study research. And it contribute to develope internal energy systems and set a new system bound.

  • PDF

생태효율성(Eco-efficiency)지표 개발을 통한 KTX와 새마을호 열차의 사용단계 환경성 평가에 관한 연구 (A Study on the Environmental Evaluation in Use Stage of KTX and Samaul Train : the Development of Eco-efficiency Indicator)

  • 최용신;천윤영;이건모;김용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1313-1320
    • /
    • 2011
  • World Business Council for Sustainable Development(WBCSD) is effort to achieve sustainable development in economic growth, environmental preservation and social development. Being this way, it is essential for developing evaluation tool which quantify to fulfill sustainable development. Eco-efficiency is one of the quantitative tools to evaluate environmental impact and economic aspect. Eco-efficiency, in general term, means creating more value of product or services with less impact to environment. It indicates as environmental impact in denominator and value of product or services in numerator. Eco-efficiency shows how much economic value reveals to unit environmental impact caused by product or service as an indicator. This study aims at developing eco-efficiency indicator of railway industry considering use stage among the entire life cycle stage of KTX and Saemaul train and also, figure out eco-efficiency value through indicator. Therethrough, it is enables to evaluate created value per environmental aspects. Since rail vehicles demands a lot of energy to transport people during use stage, the environmental impact is more significant than other lkfe cycle stages. Therefore, it quantified environmental indicator as CO2 emission and economic indicator as transportation record per a year with an annual income. This study contributes to be used as a tool for quantifying indicator of comparison evaluation in respect of rail vehicle in use stage.

  • PDF

인버터 구동 원심펌프의 급수 사용율에 따른 에너지 절감 평가 (Evaluation of Energy Savings for Inverter Driving Centrifugal Pump with Duty Cycles)

  • 김경욱;서상호;라키부자만
    • 한국유체기계학회 논문집
    • /
    • 제18권6호
    • /
    • pp.81-85
    • /
    • 2015
  • The purpose of this study is to evaluate energy savings for inverter driving multi-stage centrifugal pump. Variable speed driving pump system has high efficiency compared with constant speed driving pump system. Because of difficulty to estimate operating efficiency of variable speed driving pump system, energy saving rates are used to replace operating efficiency. energy saving rates are calculated from pump input power and pump duty cycle. But another researches have used pump duty cycles of each season for energy saving rate. In this study, for estimating energy saving rate more high accuracy, pump duty cycles are measured for 1 year. pump duty cycles, depending on the season and be classified according to the weekday/weekend or during the week day. By this pump duty cycles, Energy saving rate is calculated appropriately.

태양전지를 이용한 국내 Window Type 광전기화학 수소생산의 경제성 평가 (Economic Evaluation of Domestic Window Type Photoelectrochemical Hydrogen Production Utilizing Solar Cells)

  • 김봉진;김종욱
    • 한국수소및신에너지학회논문집
    • /
    • 제21권6호
    • /
    • pp.595-603
    • /
    • 2010
  • This paper deals with an economic evaluation of domestic window type photoelectrochemical hydrogen production utilizing solar cells. We make some sensitivity analysis of hydrogen production prices by changing the values of input factors such as the initial capital cost, the solar to hydrogen conversion efficiency, and the system duration time. The hydrogen production price of the window type photoelectrochemical system was estimated as 1,168,972 won/$kgH_2$. It is expected that hydrogen production cost can be reduced to 47,601 won/$kgH_2$ if the solar to hydrogen conversion efficiency is increased to 14%, the system duration time is increased to 20,000 hours, and the initial capital cost is decreased to 25% of the current level. We also evaluate the hydrogen production cost of the water electrolysis using the electricity produced by solar cells. The corresponding hydrogen production cost was estimated as 37,838 won/$kgH_2$. The photoelectrochemical hydrogen production is evaluated as uneconomical at this time, and we need to enhance the solar to hydrogen conversion efficiency and the system duration time as well as to reduce prices of the system facilities.

Performance Analysis of Upgrading Process with Amine-Based CO2 Capture Pilot Plant

  • Kwak, No-Sang;Lee, Junghyun;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권1호
    • /
    • pp.33-38
    • /
    • 2018
  • This study applied upgrades to the processes of a 10 MW wet amine $CO_2$ capture pilot plant and conducted performance evaluation. The 10 MW $CO_2$ Capture Pilot Plant is a facility that applies 1/50 of the combustion flue gas produced from a 500 MW coal-fired power plant, and is capable of capturing up to 200 tons of $CO_2$. This study aimed to quantitatively measure efficiency improvements of post-combustion $CO_2$ capture facilities resulting from process upgrades to propose reliable data for the first time in Korea. The key components of the process upgrades involve absorber intercooling, lean/rich amine exchanger efficiency improvements, reboiler steam TVR (Thermal Vapor Recompression), and lean amine MVR (Mechanical Vapor Recompression). The components were sequentially applied to test the energy reduction effect of each component. In addition, the performance evaluation was conducted with the absorber $CO_2$ removal efficiency maintained at the performance evaluation standard value proposed by the IEA-GHG ($CO_2$ removal rate: 90%). The absorbent used in the study was the highly efficient KoSol-5 that was developed by KEPCO (Korea Electric Power Corporation). From the performance evaluation results, it was found that the steam consumption (regeneration energy) for the regeneration of the absorbent decreased by $0.38GJ/tonCO_2$ after applying the process upgrades: from $2.93GJ/ton\;CO_2$ to $2.55GJ/tonCO_2$. This study confirmed the excellent performance of the post-combustion wet $CO_2$ capture process developed by KEPCO Research Institute (KEPRI) within KEPCO, and the process upgrades validated in this study are expected to substantially reduce $CO_2$ capture costs when applied in demonstration $CO_2$ capture plants.

공기식 태양열 흡수기의 설계 및 성능평가 (Design and Performance Evaluation of Solar Air Receivers)

  • 조현석;이현진;김종규;이상남;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.207-212
    • /
    • 2012
  • It is important to produce the high-temperature and high-pressure air for the concentrated solar power system using the combined cycle. In this paper, we designed two types of tubular receivers to heat up the compressed air and provided their preliminary experimental results for performance evaluation and further improvements. The developed receivers are in a square cavity shape surrounded by flow conduits for easy scale-up and radiation loss reduction. The two receivers were tested with 5 bar air in the KIER solar furnace and evaluated in terms of the outlet temperature and the efficiency.

건물에너지 절감을 위한 열차단 필름의 성능 평가 (Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings)

  • 남중우;원종서
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF