• Title/Summary/Keyword: Energy detector

Search Result 899, Processing Time 0.027 seconds

Evaluation of Neutron Flux Distributions of SMART-P IST Region for the Design of Ex-Core Detector (SMART 연구로 노외계측기 설계를 위한 IST 영역의 중성자속 분포 평가)

  • Koo, Bon-Seung;Kim, Kyo-Youn;Lee, Chung-Chan;Zee, Sung-Quun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2005
  • The evaluation of neutron flux distribution was performed for the ex-core detector design of SMART-P. DORT and MCNP code were used for the calculation of energy-dependent neutron flux distribution at 100% full power condition. Two code results show that maximum thermal flux appears at the $1^{st}$ water region in IST region and agree within 10% difference. In addition, another evaluation was performed code with assumptions that cote was composed of fission source and control rod without fuel assemblies. These assumptions make neutron count rate to be minimized. As a results, maximum thermal flux showed $6.99{\times}10^{-2}(n/cm^2-sec)$, when the strength of initial fission source was assumed as $1.0{\times}10^8(n/sec)$. The main reason of these results is due to the thermalization of fast neutrons in the water region and thermal flux is proportional to 80% of total neutron flux. Therefore, optimization of filler material of detector guide tube, position of installation and axial length of detector segments is necessary for the design of ex-core detector to enhance the neutron count rate and above results could be used in ex-core detector design as a fluence requirement.

Effects of element composition in soil samples on the efficiencies of gamma energy peaks evaluated by the MCNP5 code

  • Ba, Vu Ngoc;Thien, Bui Ngoc;Loan, Truong Thi Hong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.337-343
    • /
    • 2021
  • In this work, self-absorption correction factor related to the variation of the composition and the density of soil samples were evaluated using the p-type HPGe detector. The validated MCNP5 simulation model of this detector was used to evaluate its Full Energy Peak Efficiency (FEPE) under the variation of the composition and the density of the analysed samples. The results indicates that FEPE calculation of low gamma ray is affected by the composition and the density of soil samples. The self-absorption correction factors for different gamma-ray energies which was fitted as a function of FEPEs via density and energy and fitting parameters as polynomial function for the logarithm neper of gamma ray energy help to calculate quickly the detection efficiency of detector. Factor Analysis for the influence of the element composition in analysed samples on the FEPE indicates the FEPE distribution changes from non-metal to metal groups when the gamma ray energy increases from 92 keV to 238 keV. At energies above 238 keV, the FEPE primarily depends only on the metal elements and is significantly affected by aluminium and silicon composition in soil samples.

Study on the cascade summing correction for high efficiency HPGe detector (고효율 HPGe 검출기의 동시합성효과 보정 연구)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.107-112
    • /
    • 2005
  • Cascade summing occurs when two gamma-rays emitted in the decay of a single nucleus both deposit energy in a detector. The effect may cause systematic errors that can reach levels of more than ten percent for some radionuclides. A method for estimation of the effect of these coincidences was developed. It is based on direct computation of the effect by means of peak to total ratio measured for the place around the detector. It has been shown that the P/T ratio for the given energy in the working space around the detector may not be a constant value and must use its mean value. Some results from a peak to total calibration study in the presence of scattering materials are also given.

The study of the optimized collimator structure for gamma-ray detector (감마선 탐지장치를 위한 Collimator 구조 최적화 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.835-836
    • /
    • 2014
  • In this paper, we have designed the collimator of different sizes structure for the development of stereo radiation detector. And we conducted a study of the optimal structure of collimator using the results of the Gamma-ray irradiation test associated with the change of the incident angle. According to the results of the performance analysis, and showed the results of the optimal incident angle 2. Results of the paper are used as basic data for designing the structure of the detector efficiency for radiation detection.

  • PDF

The development of UV falme detector (UV 화재감지장치 개발)

  • Gwon, O-Seung;Jeong, Chang-Gi;Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.28
    • /
    • pp.48-54
    • /
    • 2000
  • The technique detects radiant energy form a flaming fire of fuels contained carbonaceous material can be applied to fast growing fires. This technique applied detectors are ultimately effective when early detecting fire alarm system is required or the smoke and heat detectors can not applied. In Korea Fire regulation, a flame detector should be install in case that the installation height is higher than 20[m], chemical plant, hangar refinery. Therefore it is really necessary that a flame detector has to be developed as soon as possible. With foundation technique of flame detector, ideal sensing element and stable circuit design, a trial UV flame detector is manufactured. The stable and reliable technique of flame detector is established through the repeateed perfomance test and modification. An early detecting fire alarm device is developed through the modification, supplement of the structure and circuit. Results of the R & D for the manufacture of an excellent flame detecting device is carried out with the establishment of technique for the mass production and the qualified manufacturing process.

  • PDF

Design and Manufacture of an Electron Detector for Scanning Electron Microscope (주사전자현미경용 전자검출기의 설계 및 제작)

  • Jeon, Jong-Up;Kim, Ji-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.4
    • /
    • pp.53-60
    • /
    • 2008
  • Electron detectors used in scanning electron microscope accept electrons emitted from the specimen and convert them to an electrical signal that, after amplification, is used to modulate the gray-level intensities on a cathode ray tube, producing an image of the specimen. Electron detector is one of the key components dominating the performance of scanning electron microscope so that the development of electron detectors having high performance is indispensable to acquire high quality images using scanning electron microscope. In this paper, we designed and manufactured an electron detector and conducted a couple of image capture experiments using it. In particular, scintillator which generates light photons when it is struck by high-energy electrons was manufactured and experimental studies on the optimization of manufacturing condition was carried out. From experiments to evaluate the performance of our detector, it was verified that the performance of our detector is equivalent to or better than that of the conventional one.

Growth and characterization of detector-grade CdMnTeSe

  • J. Byun ;J. Seo;J. Seo ;B. Park
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4215-4219
    • /
    • 2022
  • The Cd0.95Mn0.05Te0.98Se0.02 (CMTS) ingot was grown by the vertical Bridgman technique at low pressure. All wafers showed high resistivity, which suggests potential as a room-temperature semiconductor detector. The resistivity of the CMTS planar detector was 1.47 × 1010 Ω·cm and mobility lifetime product of electrons was 1.29 × 10-3 cm2/V. The spectroscopic property with Am-241 and Co-57 was evaluated. The energy resolution about 59.5 keV gamma-ray of Am-241 was 11% and the photo-peak of 122 keV gamma-ray from Co-57 was clearly distinguished. The result shows the first detector-grade CMTS in the world and proves CMTS's potential as a radiation detector operating at room temperature.

Development of Electronic Personal Dosimeter with Hybrid Preamplifier using Semiconductor Detector (반도체 검출기를 이용한 Hybrid 전치증폭기형 전자식 개인선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.;Rho, S.R.
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.51-57
    • /
    • 2002
  • An electronic personal dosimeter(EPD) with hybrid type preamplifier adopting a semiconductor detector as a radiation detector has been developed, manufactured and test-evaluated. The radiation detection characteristics of this EPD has been performance-tested by using a reference photon radiation field. After several test-irradiations to a $^{137}Cs$ gamma radiation source the radiation detection sensitivity of this EPD appeared to be $3.8\;cps/Gy{\cdot}h^{-1}$. The linearity of radiation response was kept within 8% of the dose equivalent ranges of $10{\mu}Sv{\sim}4Sv$ and the angular dependence was under less than 4% in angles of ${\pm}60^{\circ}$. It was confirmed that the energy response range was in $60{\sim}1,250keV$ given in the ISO standard. This EPD satisfied the international criteria for the EPD in the mechanical and the environmental performance test for 9 test categories according to IEC 61526.