• Title/Summary/Keyword: Energy conversion efficiency

Search Result 1,214, Processing Time 0.041 seconds

A Study of Wind Energy Conversion System by a Secondary Control Hydrostatic Transmission (2차측 제어 정유압 변속기를 이용한 풍력발전시스템에 관한 연구)

  • Do, H.T.;Ahn, K.K.
    • Journal of Drive and Control
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • Wind energy has been more and more important and contributive in the energy utilization of the world. This paper proposed a novel method for Wind Energy Conversion System (WECS), in which a secondary control hydrostatic transmission (SC-HST) with two hydraulic accumulators, were employed for wind energy conversion system. This approach can absorb the excessive power of turbine, keep the generator from over-speed and maintain the speed of generator in low speed of turbine. A PID controller was designed for speed control to track a predefined speed. The simulation results indicated that the speed of the generator was ensured with the relative error less than 2%; and the efficiency of the proposed system was 70.4%.

Power conversion control for zero emission buildings (탄소제로 빌딩을 위한 전력변환 제어)

  • Han, Seok-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.504-505
    • /
    • 2011
  • Decreasing actual greenhouse gas will be difficult if it is not solved addressed in architectural fields. Zero emission building or zero energy building, maximize the efficiency of energy, which means the building can operate by their own renewable energy facility without any other supplying. To be a zero emission building, a building needs realization of high efficiency low energy consumption, construction of building its own energy production facilities and lastly a power grid connection. According to increasing of DC load about TV, LED lighting, computer, IT in building for living and business, it is expected the save of energy when the system of AC power distribution change into the system of DC power distribution. Renewable energy exists a big different rate produced by outside environment. When electrical power overproduce, it can supply for system. Otherwise, if electrical power produce less, it can receive supply from system. Send and receive power can lead to zero to annual standard. This paper shows the simulation about efficient control of power conversion which is related to DC power distribution of architecture and DC output of renewable energy by using L-type converter.

  • PDF

A study on the fixed-concentrating hybrid panel using reflector (반사판을 이용한 고정식 집속형 복합 Panel에 대한 연구)

  • Kim, Kiu-Jo;Kim, Seung-Whan;Yoo, Hung-Chul;Kim, Wan-Tae;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.463-466
    • /
    • 2001
  • The most effective methods of utilizing solar energy are to use the sunlight and solar thermal energy such as hybrid panel simultaneously and to use concentrator. From such a view point, systems using various kinds of photovoltaic panels were constructed in the world. However there have not been a type of panel using concentrator and hybrid simultaneously. If the sunlight are concentrated on the solar cell, cell conversion efficiency increase and the temperature of the solar cells increases. As the temperature of the solar cells increases, so cell conversion efficiency decreases. Therefore, for maintaining cell conversion efficiency at these conditions, it is necessary to keep the cell at low temperature. In this paper, after designing a concentrate rate for concentrating, we proposed model for cooling cell and using waste heat, and we compared with conventional panels after calculating the electrical and thermal efficiency using energy balance equation.

  • PDF

Surface Analysis and Conversion Efficiency of Multi-crystalline Silicon Solar Cell by Wet Chemical Etching (습식 화학 식각에 의한 다결정 실리콘 웨이퍼의 표면 분석 및 효율 변화)

  • Park, Seok-Gi;Do, Kyeom-Seon;Song, Hee-Eun;Kang, Gi-Hwan;Ahn, Hyung-Keun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.111-115
    • /
    • 2011
  • Surface Texturing is an essential process for high efficiency in multi-crystalline silicon solar cell. In order to reduce the reflectivity, there are two major methods; proper surface texturing and anti-reflection coating. For texturization, wet chemical etching is a typical method for multi-crystalline silicon. The chemical solution for wet etching consists of HF, $NHO_3$, DI and $CH_3COOH$. We carried out texturization by the change of etching time like 15sec, 30sec, 45sec, 60sec and measured the reflectivity of textured wafers. As making the silicon solar cells, we obtained the conversion efficiency and relationship between texturing condition and solar cell characteristics. The reflectivity from 300nm to 1200nm was the lowest with 15 sec texturing time and 60 sec texturing time showed almost same reflectivity as bare one. The 45 sec texturing time showed the highest conversion efficiency.

  • PDF

Design and Control of Novel Topology for Photovoltaic DC/DC Converter with High Efficiency under Wide Load Ranges

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.300-307
    • /
    • 2009
  • In this paper, design and control is proposed for a four input-series-output-series-connected ZVS full bridge converter for the photovoltaic power conditioning system (PCS). The novel topology for a photovoltaic (PV) DC/DC converter that can dramatically reduce the power rating and increase the efficiency of a PV system by analyzing PV module characteristics is proposed. The control scheme, including an input voltage controller is proposed to achieve equal sharing of the input voltage as well output voltages by a four series connected module. Design methods for ZVS power stage are also introduced. The total PV system is implemented for a 250-kW PV power conditioning system (PCS). This system has only three DC/DC converters with a 25-kW power rating and uses only one-third of the total PV PCS power. The 25-kW prototype PV DC/DC converter is introduced to verify experimentally the proposed topology. In addition, an experimental result shows that the proposed topology exhibits good performance.

Design and Development of a High-Voltage Transformer-less Power Supply for Ozone Generators Based on a Voltage-fed Full Bridge Resonant Inverter

  • Amjad, Muhammad;Salam, Zainal;Facta, Mochammad;Ishaque, Kashif
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.387-398
    • /
    • 2012
  • It is known that transformer based power supplies for ozone generators have low efficiency, high cost and exhibits a limited frequency range of operation. To overcome these disadvantages, this paper proposes a high frequency ozone generator with the absence of a transformer. The voltage step-up is achieved only by utilizing the resonant tank. This is made possible by a novel combination of ozone chamber materials that allow ozone to be generated at only 1.5 - 3.5 $kV_{p-p}$. The input to the resonant tank is driven by a PWM full bridge resonant inverter. Furthermore, zero-current zero-voltage switching (ZCZVS) operation is achieved by employing a duty factor of 25% between the switches of the full bridge. The advantages of the proposed system include high efficiency, low cost and the ability to control ozone production by varying the input voltage to the inverter. The prototype is verified by both simulation and experimental results.

Ti02/CNT Hybrid Nanofiber Electrode for Energy Conversion Devices (에너지 전환 소자용 $TiO_{2}/CNT$ 하이브리드 나노 섬유 전극)

  • Seo, Jae-Sub;Kim, Joo-Yong;Jin, Hyoung-Joon;Kang, Min-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.323-325
    • /
    • 2007
  • $TiO_{2}$ electrode electrospun directly onto the substrate was developed for energy conversion device. To enhance energy conversion efficiency of dye-sensitized solar cell, electrodes should have higher surface area to absorb more dyes and higher conductivity to reduce recombination of generated electrons. $TiO_{2}$ nanofibers with higher surface areas were fabricated by annealing electrospun $TiO_{2}/PVP$ nanofibers at $500^{\circ}C$ for 3 hrs in air. it was revealed that $TiO_{2}$ nanofiber electrodes is hybrid with MWNT showed higher conductivity than $TiO_{2}$ semiconductor electrode possibly due to band gap change.

  • PDF

A New Ionic Liquid for a Redox Electrolyte of Dye-Sensitized Solar Cells

  • Kang, Man-Gu;Ryu, Kwang-Sun;Chang, Soon-Ho;Park, Nam-Gyu
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.647-652
    • /
    • 2004
  • A new ionic liquid, 1-vinyl-3-heptylimidazolium iodide (VHpII), was synthesized and applied as a redox electrolyte for dye-sensitized solar cells. The chemical structure of the synthesized VHpII was confirmed using $^1H$ NMR. Thermogravimetric analysis showed that the VHpII was stable for thermal stress of up to $250^{\circ}C$. The energy conversion efficiencies of the VHpII-based dye-sensitized solar cells were investigated in terms of the effect of a lithium iodide addition. A solar cell containing the redox couple of VHpII and iodine showed a conversion efficiency of 2.63% under 1 sun light intensity at AM 1.5. Adding 0.4 M LiI results in a conversion efficiency of 3.63%, which was an improvement of about 40%. The increased conversion efficiency was ascribed to an increase in external quantum efficiency.

  • PDF

A Study on Emissions and Catalytic Conversion Efficiency Characteristics of an Electronic Control Engine Using Ethanol Blended Gasoline as Fuels

  • Cho Haeng-Muk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.722-728
    • /
    • 2005
  • In this paper, the effects of ethanol blended gasoline on emissions and their catalytic conversion efficiency characteristics were investigated in a multiple-point EFI gasoline engine, The results show that with the increase of ethanol concentration in the blended fuels, THC emissions were drastically reduced by up to thirty percent, And brake specific fuel consumption was increased, but brake specific energy consumption could be improved. However, unburned ethanol and acetaldehyde emissions increased. Pt/Rh based three-way catalysts were effective to reduce acetaldehyde emissions, but had low catalytic conversion efficiency for unburned ethanol. The effect of ethanol on CO and NOx emissions and their catalytic conversion efficiency had close relation to the engine's speed, load and air/fuel ratio. Furthermore fuels blended with thirty percent ethanol by volume could dramatically reduced THC CO and NOx emissions at idle speed.

Gasification of Coal and Torrefied Biomass Mixture (석탄과 반탄화 바이오매스 혼합연료의 가스화)

  • OH, GUNUNG;JANG, JIN YOUNG;RA, HO WON;SEO, MYUNG WON;MUN, TAE YOUNG;LEE, JAE-GOO;YOON, SANG JUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.190-199
    • /
    • 2017
  • Air-blown Gasification of coal and torrefied biomass mixture is conducted on fixed-bed gasifier. The various ratio (9:1, 8:2, 7:3) of coal and torrefied biomass mixture are used. The contents of $H_2$, CO in the syngas were increased with gasification temperature. Carbon conversion tend to increase with temperature and equivalence ratio (ER). However, cold gas efficiency showed maximum point in ER range of 0.26-0.36. The torrefied biomass showed highest cold gas efficiency of 67.5% at $934^{\circ}C$, ER 0.36. Gasification of 8:2 mixture showed the highest carbon conversion and cold gas efficiency and synergy effect.