• Title/Summary/Keyword: Energy consumption comparison

Search Result 448, Processing Time 0.027 seconds

Energy-Aware Self-Stabilizing Distributed Clustering Protocol for Ad Hoc Networks: the case of WSNs

  • Ba, Mandicou;Flauzac, Olivier;Haggar, Bachar Salim;Makhloufi, Rafik;Nolot, Florent;Niang, Ibrahima
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.11
    • /
    • pp.2577-2596
    • /
    • 2013
  • In this paper, we present an Energy-Aware Self-Stabilizing Distributed Clustering protocol based on message-passing model for Ad Hoc networks. The latter does not require any initialization. Starting from an arbitrary configuration, the network converges to a stable state in a finite time. Our contribution is twofold. We firstly give the formal proof that the stabilization is reached after at most n+2 transitions and requires at most $n{\times}log(2n+{\kappa}+3)$ memory space, where n is the number of network nodes and ${\kappa}$ represents the maximum hops number in the clusters. Furthermore, using the OMNeT++ simulator, we perform an evaluation of our approach. Secondly, we propose an adaptation of our solution in the context of Wireless Sensor Networks (WSNs) with energy constraint. We notably show that our protocol can be easily used for constructing clusters according to multiple criteria in the election of cluster-heads, such as nodes' identity, residual energy or degree. We give a comparison under the different election metrics by evaluating their communication cost and energy consumption. Simulation results show that in terms of number of exchanged messages and energy consumption, it is better to use the Highest-ID metric for electing CHs.

Analysis of the Relationship between Urban Characteristic Elements by Type of City and GHG Emissions (도시 유형별 도시특성요소와 온실가스 배출량 간의 관계 분석)

  • Lee, Gunwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.62-71
    • /
    • 2017
  • This study classified cities across South Korea according to their urban characteristics, selecting representative cities for respective types, and drawing a relationship among urban characteristic elements, carbon emissions, and the energy consumption of cities. For the classification of cities, the elements of the urban characteristics were examined through a review of the related literature. Factor analysis was then carried out to select the variables from among these elements. The absolute coefficient value found in the analysis was set as a standard. A classification of cities across the country was performed using these variables, and representative cities were chosen for a comparison of the characteristics of each type. For an analysis of the relationships among the urban characteristics according to the type of city, the greenhouse gases, and the energy consumption of cities, emissions of greenhouse gases, electricity consumption, and oil consumption of the representative cities were compared and analyzed by correlation analysis. The analysis results indicated that the cause of greenhouse gas emissions and electricity consumption varies according to the elements of the characteristics of the representative cities, even when they show similar emissions and consumption.

A Study on the Optimal Design of Urban Energy Supply Systems (도시기반 에너지공급시스템의 최적화 방안 연구)

  • Kim, Yong-Ki;Lee, Tae-Won;Woo, Nam-Sub
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.396-402
    • /
    • 2009
  • Recently many efforts have been carried out on the development of energy-efficient and environment-friendly systems in order to preserve natural environment and to reduce environmental loads in the branch of the urban planning and the building design. In this study, a mathematical method was developed and a numerical analysis was carried out with various parameters to provide substantial data for optimal design and operation of urban energy supply systems. Components of the system and their specifications, such as a co-generation system and other heating and cooling systems, could be obtained through this analysis for various resource and energy requirements in urban area. In this study, the system constituents and operating characteristics, and their economic performances such as the value of objective function, the amount of energy consumption were discussed for various load patterns and power load ratios. Also, it turns out that the optimal energy supply system can save energy by $10{\sim}20%$ in comparison with the conventional energy supply system.

Effects of Treadmill Gait Training on Gait Patterns in Hemiplegic Patients comparison with conventional gait training (편마비 환자에서 트레드밀 보행훈련이 보행에 미치는 효과 - 지면 보행훈련과의 비교 -)

  • Kim, Hee-Hyun;Hur, Jin-Gan;Yang, Young-Ae
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.17-28
    • /
    • 2003
  • The aim of this study was to investigate the effects of treadmill gait training on the functional characteristics and the temporal-distance parameters of gait in hemiplegic patients, as compared with conventional gait training. The subjects of this study were 32 hemiplegic patients who had been admitted or were visited out-patients at Kangdong Sacred Heart Hospital, Hallym University, from March 3 through April 25, 2003. These subjects were randomly divided into treadmill gait training group or conventional gait training group. We evaluated the gait ability, motor functions, muscle strength, spasticity, physiological cost index, and temporal-distance parameters. We analyzed the changes between pre and post training in each groups, and the difference between two groups. Temporal-distance parameters were obtained using the ink footprint method and then energy consumption using physiological cost index. The results were as follows: 1. After a six-week training, treadmill gait training group significantly improved, as. compared to pre-training, in gait ability, motor functions for the leg and trunk and gross function, muscle strength of the lower limb, gait speed, cadence, step length both on the affected and on the unaffected side, step length symmetry, and energy consumption(p<0.05). 2. After a six-week training, conventional gait training group significantly improved, as compared to pretraining, in gait ability, motor functions for the leg and trunk, muscle strength of the lower limb, spasticity the upper limb, gait speed, cadence, step length both on the affected and on the unaffected side, and energy consumption(p<0.05). 3. After a six-week training, the treadmill gait training group significantly improved, as compared to the conventional gait, training, in gait speed and step length on the unaffected side. These results show that treadmill gait training was improved gait speed and step length on the unaffected side of hemiplegic patients, as compared with conventional gait training. Further research is needed to confirm the generalization of these findings and to identify which hemiplegic patients might benefit from treadmill gait training.

  • PDF

Hospital Outpatients are Satisfactory for Case-control Studies on Cancer and Diet in China: A Comparison of Population Versus Hospital Controls

  • Li, Lin;Zhang, Min;Holman, C. D'Arcy J.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.2723-2729
    • /
    • 2013
  • Background: To investigate the internal validity of a food-frequency questionnaire (FFQ) developed for use in Chinese women and to compare habitual dietary intakes between population and hospital controls measured by the FFQ. Materials and Methods: A quantitative FFQ and a short food habit questionnaire (SFHQ) were developed and adapted for cancer and nutritional studies. Habitual dietary intakes were assessed in 814 Chinese women aged 18-81 years (407 outpatients and 407 population controls) by face-to-face interview using the FFQ in Shenyang, Northeast China in 2009-2010. The Goldberg formula (ratio of energy intake to basal metabolic rate, EI/BMR) was used to assess the validity of the FFQ. Correlation analyses compared the SFHQ variables with those of the quantitative FFQ. Differences in dietary intakes between hospital and population controls were investigated. Odds ratios (ORs) and 95% confidence intervals (CIs) were obtained using conditional logistic regression analyses. Results: The partial correlation coefficients were moderate to high (0.42 to 0.80; all p<0.05) for preserved food intake, fat consumption and tea drinking variables between the SFHQ and the FFQ. The average EI/BMR was 1.93 with 88.5% of subjects exceeding the Goldberg cut-off value of 1.35. Hospital controls were comparable to population controls in consumption of 17 measured food groups and mean daily intakes of energy and selected nutrients. Conclusions: The FFQ had reasonable validity to measure habitual dietary intakes of Chinese women. Hospital outpatients provide a satisfactory control group for food consumption and intakes of energy and nutrients measured by the FFQ in a Chinese hospital setting.

Electrochemical Advanced Oxidation of Lamotrigine at Ti/DSA (Ta2O5-Ir2O5) and Stainless Steel Anodes

  • Meena, Vinod Kumar;Ghatak, Himadri Roy
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.292-307
    • /
    • 2022
  • The study presents kinetics of degradation and mineralization of an anti-epileptic drug Lamotrigine (LAM) in the aqueous matrix by electrochemical advanced oxidation process (EAOP) on Ti/DSA (Ta2O5-Ir2O5) and Stainless Steel (SS) anodes using sodium sulphate as supporting electrolyte. On both the anodes, kinetic behaviour was pseudo-first-order for degradation as well as mineralization of LAM. On Ti/DSA anode, maximum LAM degradation of 75.42% was observed at an associated specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 100 ppm Na2SO4 concentration. Maximum mineralization attained was 44.83% at an associated specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 50 ppm concentration of Na2SO4 with energy consumption of 2942.71 kWh/kgTOC. Under identical conditions on SS anode, a maximum of 98.92% LAM degradation was marked after a specific charge (Q) of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 100 ppm concentration of Na2SO4. Maximum LAM mineralization on SS anode was 98.53%, marked at a specific charge of 3.1 (Ah/litre) at a current density of 1.38 mA/cm2 and 75 ppm concentration of Na2SO4, with energy consumption of 1312.17 kWh/kgTOC. Higher Mineralization Current Efficiency (MCE) values were attained for EAOP on SS anode for both degradation and mineralization due to occurrence of combined electro-oxidation and electro-coagulation process in comparison to EAOP on Ti/DSA anode due to occurrence of lone electro-oxidation process.

An Energy-Efficient Routing Protocol based on Static Grid in Wireless Sensor Networks (무선 센서 네트워크에서 정적 그리드 기반의 에너지 효율적 라우팅 프로토콜)

  • Choi, Jae-Min;Mun, Hyung-Jin;Jeong, Yoon-Su;Lee, Sang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.8A
    • /
    • pp.791-800
    • /
    • 2010
  • Recently wireless sensor networks as a field of ubiquitous computing technology was in the limelight. To use and collect the necessary information, Sink node mobility is essential. TTDD(Two-Tier Data Dissemination) proposed most common technique associated with Mobile sink node in wireless sensor networks, but issues exist that the use of many control packet falls into the energy efficiency. The technique for solving problems is Cluster-Based Energy-efficient Routing protocol (CBPER). But CBPER does not transmit the data correctly to sink node or source node. In this paper, we propose An Energy-Efficient Routing Protocol based on Static Grid using mobile sink nodes in order to solve the data transmission failure and reduce the energy consumption in Wireless Sensor Networks. We have evaluated it with the NS-2 simulator. Our results show that the proposed protocol saves the energy consumption up to 34% in comparison with CBPER. We also prove that the proposed protocol can transmit more accurate data to the sink de than CBPER.

The Comparison of Heart Rate and Energy Expenditure between Male and Female During Twist Exercise (트위스트 운동 시 성별에 따른 심박수와 에너지 소모량의 비교)

  • Jeon, Byeong-Hwan
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.1
    • /
    • pp.243-252
    • /
    • 2015
  • The present study, to examine the effect of the exercise for weight control, compares the difference of the heart rate and energy expenditure by sex during Twist exercise. Twenty eight adults (male 14, female 14) were carried out Twist exercise for 7 minutes and 14 minutes. During performing the exercise program, to perform HR and related variables were measured for 7 minutes and 14 minutes. Through a twist exercise treatment and the following results were obtained. 1. Females had slightly higher, without statistical significance, number of heart beat, minimum heart rate, maximum heart rate, and average heart rate than male had for both 7 minutes and 14 minutes of Twist exercise. 2. In the case of energy consumption, significant differences did not appear until 7 minutes to perform Twist exercise. On the other hand, the energy consumption for 14 minutes of performance was significantly higher in male than in female (p<.05). However, energy expenditure for the period per minute per unit weight (kcal/min/kg) showed no difference. 3. If more than 30 minutes duration were preformed the Twist exercise, males were expected to consume significantly higher than females (p<.05). To consume calories for the 10,000 step walk of, it would be required about 76 minutes for Twist exercise time without distinction of sex. Through the above findings, twist exercise is a form of aerobic exercise for obesity prevention and weight control, as well as it might be beneficial to practice and maintain the health and physical fitness with offering a variety of exercise opportunities in the public.

Comparison on the Energy Consumption of the Vacuum Evaporation and Hydrated-Based Technologies for Concentrating Dissolved Ions (용존 이온 농축을 위한 진공 증발 기술과 하이드레이트 기반 기술의 소모 에너지 비교)

  • Han, Kunwoo;Rhee, Chang Houn;Ahn, Chi Kyu;Lee, Man Su
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.378-386
    • /
    • 2019
  • In the present paper we report the calculation results of operation energy consumption for dissolved ions concentration technologies using vacuum evaporation (VE) and hydrate formation. Calculations were conducted assuming the tenfold concentration of saline water (0.35 wt% NaCl solution) of 1 mol/s at room temperature and atmospheric pressure employing vacuum evaporation at $69^{\circ}C$ and 30 kPa and hydrate-based concentration using $CH_4$, $CO_2$ and $SF_6$ as guest molecules. Operation energy consumption of VE-based concentration resulted in 47 kJ/mol, whereas those of hydrate-based concentration were 43, 32, and 28 kJ/mol for $CH_4$, $CO_2$ and $SF_6$ hydrates, respectively. We observe that hydrate-based concentration can a competitive option for dissolved ions recovery from energy consumption standpoint. However, the selection of guest gas is very critical, since it accordingly determines the hydration number, the hydrate formation energy, gas compression energy, etc. The selection of guest gas, separation of concentrated brine and water phases, and the enhancement of hydrate formation rate are the key factors for the commercialization of hydrated-based technology for concentrating dissolved ions.

Comparative study on one and two-path single energy recovery circuit for plasma display panel (PDP)

  • Yi, Kang-Hyun;Choi, Seong-Wook;Moon, Gun-Woo;Park, Jung-Pil;Jung, Nam-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.256-259
    • /
    • 2006
  • Comparison of one two-path single energy recovery circuit for plasma display panel (PDP) is shown in this paper. A single energy recovery circuit (SERC) is proposed to reduce cost for manufacturing PDP and there are two ways, one and two-path, in driving this circuit. Compared with one-path SERC, there are low power consumption, low surge current and high performance in two-path SERC. The results will be shown with 42-inch HD panel.

  • PDF