• Title/Summary/Keyword: Energy consumption

Search Result 6,332, Processing Time 0.036 seconds

A Study on the Evaluation of Building Energy Rating considering the Insulation performance of the Window in Apartment houses (공동주택에서의 창호성능에 따른 건물에너지 효율등급 평가 연구)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Hong, Sung-Hee;Jang, Cheol-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.291-295
    • /
    • 2009
  • As a reasonable energy policy has become required because of consuming substantial amounts of oil than others, the studies on energy consumption are in work for energy savings of buildings that spend up to 24% of total energy consumption. However, there aren't basic data on energy consumption and installationregulations for effective equipments in energy guzzled buildings. The best plan to reduce the building energy consumption is that the insulation performance should be improved because the insulation and airtight of building envelopes have an effect on the energy consumption basically. Thus, we should prepare the alternatives to improve insulation performance of envelopes and the efficiency of insulation performance of the window for reducing energy consumption.

  • PDF

Analysis of Effects of Building Energy Consumption Characteristics on the Optimization Ratio for New and Renewable Energy Systems (건물에너지사용특성이 신재생에너지시스템 최적화 비율에 미치는 영향분석)

  • Lee, Yong-Ho;Hong, Jun-Ho;Kim, Yong-Kyoung;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.117-126
    • /
    • 2014
  • This study developed a KRESS program designed to find the optimization ratio for new and renewable energy systems and analyze the effects of building energy consumption characteristics on the ratio. In spite of clear differences in predicted energy consumption and energy consumption by the loads among 18 facilities, the current formula for obligatory supply ratios applies a correction coefficient according to the building purposes based on energy consumption per each unit area in medical facilities and thus reflects no energy consumption characteristics according to the building purposes. The optimization ratio for new and renewable energy systems was the same for all facilities when the correction coefficients by the building purposes and new and renewable energy sources were all applied. When the correction coefficients were not applied, however, the optimization ratio varied according to building energy consumption characteristics. The findings raise a need to test the correction coefficients in order to select new and renewable energy systems that take into account energy consumption characteristics by the building purposes and loads and reflect economy, environmental performance, and technology.

A Study on the Characteristics of Electric Power Consumption of University (종합대학의 전력에너지 부하 특성에 관한 연구)

  • Lee, Choun-Mi;Kim, Ju-Young;Hong, Won-Hwa
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.336-341
    • /
    • 2008
  • For the last half a century, Korea has been experienced rapid economic growth and industrialization development, however they cause serious problems that environment pollution and energy shortage are appeared, and the biggest problem that we are now confronted are required solutions through all over the world. Now, Korea's energy consumption is the 10th in the whole world. Among them, energy for buildings, about 25% in the whole Energy which spend in Korea, is very serious. Especially, the energy consumption of school buildings which have heating & cooling system according to improvements of educational environment are rapidly increasing. These features are explicit in the University, Because it has lots of colleges and facilities for lecture, experiment, and research. Especially, electric power consumption account for 75 percent of energy consumption in educational institutions. Accordingly, it is important to understand and analyze the pattern of electricity energy consumption which is used. This study attempts to appoint the place which is one of university and to investigate the characteristics of energy consumption like electricity, gas, oil.

  • PDF

Mobile application to evaluate existing university buildings using building information

  • Chung, Min-Hee
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.13-20
    • /
    • 2016
  • Purpose: The purpose of this study is to provide information on building's energy consumption and efficiency for general building users through a mobile application. Method: This paper presents a mobile application process and building energy assessment models for general users to understand easily. There are two assessment models, one is based on the energy consumption. The other is based on the architectural planning factors of a building. The assessment models are proposed to understand buildings' energy efficiency and to compare the energy consumption level for general users. The applicability of proposed application has been evaluated by conducting a case study. The case study is targeting university buildings. Result: Energy efficiency potentials were proposed using weighting factor which was calculated by the impact on energy consumption of a building according to parameters. The mobile application used the simple energy assessment model by energy efficiency potentials and was developed for a smartphone By using the mobile application, numerous general users of smartphones can easily and conveniently access information pertaining to buildings, energy consumption, and reductions in energy consumption. The proposed application enables user to find more energy efficient buildings by comparing energy status and energy efficiency potential by given information.

A Study on the Improvement Plans of Energy Performance in University Building through the Analysis of Energy (에너지 해석을 통한 대학건물의 에너지 성능개선 방안에 관한 연구)

  • Jung, Jae-Woong;Kim, Dong-Woo;Seok, Ho-Tae;Yang, Jeong-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.50-60
    • /
    • 2010
  • Today, the amount of energy consumption in the university campuses is huge. The effort for the energy consumption reduction in university campuses is certainly needed by the following reason; first, contribution to the greenhouse gas discharge reduction demand. Second, energy cost reduction in university campus. Third, contribution to the improvement of the social awareness as the maximum higher educational institutions. The energy consumption analysis of current situation has to be executed for the energy consumption reduction in university campus. The energy reduction possibility in which it exists in university campuses can be understood through the energy consumption analysis. And the application is possible as fundamental data of the policy establishment for the effective energy reduction in university campuses. Especially, the best way to reduce the energy consumption in university campuses that is the energy consumption reduction of buildings. Accordingly, this study derived the plans for improving the performance of energy in the university building by analyzing case study, so this study analyzed the performance of energy for the university building through VE, a program for the analysis of building energy. Based on this result, this study classified the plans improving the efficiency of energy in university building into the plan for passive control and active control respectively, and suggested some concrete plans, and finally evaluated the performance of decreasing energy consumption for each plan.

A Study on the Calculation of Thermal Consumption Unit of Apartment (공동주택의 열사용량원단위 산정에 관한 연구)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.388-393
    • /
    • 2014
  • Energy consumption unit in a building is classified according to uses of electricity, gas, and oil, and it has been studied steadily as a material for establishing policy standards for energy saving in buildings. Meanwhile, consumption unit in apartment house can be calculated differently according to its survey method and area standard. Therefore, with the necessity of reestablishing energy consumption unit, this study has researched thermal energy consumption, Supply dwelling area Exclusive dwelling area, completion year and housing type of 23,791 households of 31 complex in Daejeon. As a result, (1) there was about 20% difference between supply and exclusive dwelling areas. (2) On the basis of exclusive dwelling area, thermal energy consumption unit was calculated as $104.9kWh/m^2{\cdot}a$ in 2010, $104.6kWh/m^2{\cdot}a$ in 2011, and $107.7kWh/m^2{\cdot}a$ in 2012.

A study on energy saving and economic analysisy calculation of far-infrared radiation oven (원적외선 복사오븐의 에너지 절감평가 및 경제성분석)

  • Kim, Yong-Ha;Yoo, Jeong-Hui;Lee, Gwong-Sung;Heo, Dong-Lyul;Yon, Hyeon-Su;Lee, Seong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1270-1271
    • /
    • 2011
  • A study on the energy consumption(weigh against of the energy consumption for analyzed oven) and the energy consumption of follow cooking time (weigh against of cooking time for analyzed oven)through weigh against far-infrared radiation oven and other system. for this study, analysis the energy consumption follow temperature change and calculate the energy consumption until come to saturation temperature. also, the energy consumption is measured for food analysis follow cooking time. The energy reduced cost and time is estimated.

  • PDF

A Study on the Improvement of Energy Efficiency in Warehouses (물류센터의 에너지 효율 개선 방안에 관한 연구)

  • Sun, Jong-Keun;Ryoo, Ho-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.66-72
    • /
    • 2012
  • The main sources of energy consumption in warehouses are MHE(Material Handling Equipment), HVAC(Heating, Ventilating and Air Conditioning) and Lighting. Warehouses in advanced countries raise energy efficiencies with energy consumption diagnosis, technology development and systematic management and improvements for MHE, HVAC and Illuminating, etc. They have managed illuminating system, air conditioning, motor driven system, air circulation method, dock facility, layout, AS/RS, conveyor system and battery management, etc. Ansong Pyeongtaek area investigation resulted that 43.9[%] of enterprises are managing partly energy consumption source. But the data resulted with not substantial management of energy consumption but passive management for only electric bill curtailment. Therefore through survey research & visiting interviews of some companies in Ansong Pyeongtaek area, we understood the status of energy consumption source management and proposed energy efficiency methods on the basis of that results.

A Study on the Evaluation of the Building Energy Efficiency in Accordance with the Shapes of the Apartment Unit Plans (아파트 단위세대 평면 형태에 따른 건물에너지효율 평가)

  • Kim, Chang Sung;Seo, Kyung Wook
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.55-62
    • /
    • 2013
  • Korea Government have carried out various policies to reduce the energy consumption that cause the global warming and environmental pollution. Energy consumption of buildings in Korea has reached 24% of total energy quantities and energy consumption of apartment has been continuously increasing. It has executed the building energy efficiency rating system and energy performance assessments and certification systems have been in force to save energy consumption of buildings. Therefore, this study tried to asset the energy performance of apartment according to the shapes of unit plan, and then to evaluate the energy performance of apartment according to altering balcony area into living area in the unit plan of apartment and thus, to present the effective unit plan to reduce the energy consumption. According to the results, in case of standard unit plan, the 3Bay and 4Bay unit plans showed more effective energy consumption than the 2Bay unit plan, respectively, 5%, 6%, and in case of extended unit plan, respectively, 2%, 5%. Compared the energy efficiencies of the standard unit plan to the extended unit plan, the standard one showed more effective energy consumption than the extended one, respectively, 2% in case of the 2Bay and 4Bay unit, 5% of the 3Bay unit.

Analysis of the Factor of Renewable Energy Consumption in Korea, China and Japan (한.중.일의 신재생에너지 소비량 결정 요인 분석에 관한 연구)

  • Jeon, Mi-Hwa;Jang, Woon-Jeong;Kim, Yoon-Kyung
    • New & Renewable Energy
    • /
    • v.6 no.3
    • /
    • pp.13-21
    • /
    • 2010
  • This paper analyzes the factors of renewable energy consumption in Korea, China and Japan. We consider renewable energy consumption per capita as dependent variable, GDP per capita, $CO_2$ emissions per capita and real oil prices as independent variables. To analyze this model, this paper uses three econometric methods such as OLS, fixed effect model and panel GLS, utilizing data from 1990 to 2006 in Korea, China and Japan. According to the results by OLS for each country, an increase in GDP per capita or $CO_2$ emissions per capita or oil prices leads to an increase in renewable energy consumption. According to the results by fixed effect model, an increase in GDP per capita or $CO_2$ emissions per capita leads to an increase in renewable energy consumption. And real oil prices do not have a significant impacts on this model. According to the results by panel GLS, an increase in real GDP per capita as a proxy of income leads to an increase renewable energy consumption. And both $CO_2$ emissions per capita and real oil prices do not correlated closely with renewable energy consumption. Thus oil is not substituted to renewable energy in Northeast asian countries.