• Title/Summary/Keyword: Energy calibration

Search Result 428, Processing Time 0.024 seconds

Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT

  • Jeong, Dae-Kyo;Lee, Sam-Sun;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.273-279
    • /
    • 2019
  • Purpose: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT)(Siemens Healthineers, Erlangen, Germany). Materials and Methods: A bone density calibration phantom with 3 HA inserts of different densities(CTWATER®; 0, 100, and 200 mg of HA/㎤) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time. Results: Hydroxyapatite density was strongly correlated with HU values(correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels(correlation coefficient= -0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU(P>0.05). Conclusion: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.

Prediction of the Digestibility and Energy Value of Corn Silage by Near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 옥수수 사일리지의 소화율 및 에너지 평가)

  • Park Hyung-Soo;Lee Jong-Kyung;Lee Hyo-Won;Kim Su-Gon;Ha Jong-Kyu
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.26 no.1
    • /
    • pp.45-52
    • /
    • 2006
  • This study was carried out to explore the accuracy of Near Infrared Reflectance Spectroscopy (NIRS) fer the prediction of digestibility and energy value of corn silages. The spectral data were regressed against a range of digestibility and energy parameters using modified partial least squares(MPLS) multivariate analysis in conjunction with first and second order derivatization, with scatter correction procedure(SNV-Detrend) to reduce the effect of extraneous noise. Calibration models for NIRS measurements gave multivariate correlation coefficients of determination$(R^2)$ and standard errors of cross validation of 0.92(SECV 1.73), 0.91(SECV 1.13) and 0.93(SECV 1.74) for in vitro dry matter digestibility(IVDMD), in vitro true digestibility(IVTD), and cellulase dry matter digestibility(CDMD), respectively. The standard error of prediction(SEP) and the multiple correlation coefficient of validation$(R^2v)$ on the validation set(n=39) was used in comparing the prediction accuracy. The SEP value was 0.30(TDN), 0.01(NEL), and 0.01(ME). The relative ability of NIRS to predict digestibility and energy value was very good for CDMD, total digestible nutrients(TDN), net energy fer lactation(NEL) and metabolizable energy(ME). This paper shows the potential of NIRS to predict the digestibility and energy value of con silage as a routine method in feeding programmes and for giving advice to farmers.

Development of Monoenergetic Photon Source in the Energe Range below 100 keV by the X-ray Fluorescence Method (형광 X 선을 이용한 100 KeV 이하의 에너지 영역에서의 단색 Photon 선원개발에 관한 연구)

  • Lee, Youn-Myoung;Lee, Kun-Jai;Hah, Suck-Ho;Hwang, Sun-Tae;Lee, Kyung-Ju
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.14-28
    • /
    • 1985
  • The development of mono energetic photon sources using $K_{\alpha}$ fluorescence X-ray of pure material was carried out in the energy range below 100 keV. The monoenergetic photons are very useful in the calibration of the radiation measuring instruments and can be produced as the $K_{\alpha}$ fluorescence X-ray by irradiating the bremsstrahlung to the thin pure metal foils called ‘radiators’. In this experiment, several radiators such as $_{47}Ag,\;_{50}Sn,\;_{68}Er,\;_{70}Yb,\;and\;_{82}Pb$ provide the wide monoenergetic photon energy ranging from 20 keV to 80 keV. By the spectrometry with HpGe LEPS, spectral purity factors which measure the monochrometicity for the $K_{\alpha}$ fluorescence X-ray, were determined as $0.64{\sim}0.94$. Dosimetry for the purpose of the determination of the exposure rate with a 600cc thin window ionization chamber, which was calibrated by the standard free-air ionization chamber, was performed. Exposure rates ranging $8.3{\sim}232.5mR/h$ was obtained according to the $K_{\alpha}$ fluorescence X-ray energy for each radiator.

  • PDF

Evaluation of Critical Flow Function by Using Helmholtz Free Energy for Natural Gas Flow Measurement (천연가스 유량 측정에서 헬름홀츠 자유에너지를 이용한 임계유동함수 계산)

  • Ha, Young-Cheol;Her, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1167-1173
    • /
    • 2013
  • This study aimed to calculate the CFFs (critical flow functions) of a sonic nozzle bank with a 12-nozzle package within 1 s. Toward this end, the Helmholtz free energy of natural gas was formulated by using the AGA8-dc equation of state in a form without integral terms, and thereafter, thermodynamic properties such as the enthalpy, entropy, speed of sound, and heat capacity, which are used in CFF calculation, were derived in analytical form. As a result, the calculation time of CFFs was improved from 6.7 s in a previous study to 0.6 s per 12-nozzle package and kept almost constant regardless of the number of components in natural gas. Furthermore, it was confirmed that the calculated CFF values were in agreement with the results of a CFF international comparison test carried out under ISO management in 1998-1999.

Prediction of Nutrient Composition and In-Vitro Dry Matter Digestibility of Corn Kernel Using Near Infrared Reflectance Spectroscopy

  • Choi, Sung Won;Lee, Chang Sug;Park, Chang Hee;Kim, Dong Hee;Park, Sung Kwon;Kim, Beob Gyun;Moon, Sang Ho
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Nutritive value analysis of feed is very important for the growth of livestock, and ensures the efficiency of feeds as well as economic status. However, general laboratory analyses require considerable time and high cost. Near-infrared reflectance spectroscopy (NIRS) is a spectroscopic technique used to analyze the nutritive values of seeds. It is very effective and less costly than the conventional method. The sample used in this study was a corn kernel and the partial least square regression method was used for evaluating nutrient composition, digestibility, and energy value based on the calibration equation. The evaluation methods employed were the coefficient of determination ($R^2$) and the root mean squared error of prediction (RMSEP). The results showed the moisture content ($R^2_{val}=0.97$, RMSEP=0.109), crude protein content ($R^2_{val}=0.94$, RMSEP=0.212), neutral detergent fiber content ($R^2_{val}=0.96$, RMSEP=0.763), acid detergent fiber content ($R^2_{val}=0.96$, RMSEP=0.142), gross energy ($R^2_{val}=0.82$, RMSEP=23.249), in vitro dry matter digestibility ($R^2_{val}=0.68$, RMSEP=1.69), and metabolizable energy (approximately $R^2_{val}$ >0.80). This study confirmed that the nutritive components of corn kernels can be predicted using near-infrared reflectance spectroscopy.

MEASUREMENTS OF METABOLIC PARAMETERS IN LACTATING DAIRY COWS WITH NEAR INFRARED SPECTROSCOPY ANALYSIS USING CATTLE FAECAL SAMPLES

  • De la roza, Begona;Martinez, Adela;Modrono, Sagrario;Argamenteria, Alejandro
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1629-1629
    • /
    • 2001
  • The knowledge of the nutrition in animal production is difficult to assess due of difficulty to determine the amount and quality of feeds intake, mainly if forages are the most important compound in the diet. It must be able to know responses to the metabolic process in lactating dairy cows earring out feeds evaluation trials. These metabolism studies with cows, requires measurements of: I) The amount of all feeds consumed. II) Excretion of faeces. III) Excretion of urine. Taking as a basis these trials, forage and total intake, dietary digestibility and balances of nitrogen and energy can be calculated. However, these feeds evaluation experiments with animals are very time consuming and expensives. The faeces excreted by animals containt undigested residues of the diet consumed. For this reason, their analysis can be an successful tool to determine the amount and quality of feed intake and other important biological parameters. The aim of this work was to know if faeces analysis by NIR could be used to determine with enough accuracy some attributes of different lactating dairy cows diets, using a global equation, developed on an heterogeneus population. For this purpose a total of 79 faecal samples from eight grass, three grass silages and two maize silages metabolic trials, on six cows each one, were used to constitute the initial population. The calibration equations were developed to predict forage and total intake, organic matter digestibility, digestibility coefficient of crude energy and digestibility energy. The combination of several trials with different diets and animal conditions gave promising results.

  • PDF

A New Analytical Method for the $Dy^{3+}$ Ion Using the Luminescence Enhancement by the Treatment of o-Phenanthroline on the TLC Plate (TLC Plate에서의 발광증폭 및 o-Phenanthroline에 의한 Energy Transfer를 이용한 $Dy^{3+}$ 이온의 미량 분석법)

  • Jeong, Hyuk
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.386-393
    • /
    • 1998
  • A new analytical luminescence method for the $Dy^{3+}$ ion was studied using the luminescence enhancement by the treatment of the o-phenanthroline on the TLC plate. Compared to the specific emission intensities of the ion in water solution, if the ion solution is spotted on the TLC plate, the luminescence intensities were extremely enhanced. There was additional enhancement effect of the luminescence intensities of the ions on the TLC plate, if the ion on the TLC plate is treated with o-phenanthroline. Based on the luminescence enhancement, the detection limit was improved by more than 4 order of magnitude compared to that of solution sample. The dynamic ranges and correlation coefficients of the calibration curves near the detection limit were 102 order and ~0.99, respectively. The energy-transfer mechanism was explained for the theoretical back ground of the luminescence enhancement.

  • PDF

Measurement of Radon and its Daughters Concentration in Air (공기중 라돈 및 라돈 자핵종의 농도 측정)

  • Park, Y.W.;Ha, C.W.;Ro, S.G.
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.23-29
    • /
    • 1989
  • A Lucas cell was established and calibrated by using the double layer tube standard radon source. The calibration factors were 0.031$\pm$0.002 (pCi/l)/(cph/Cell) at room temperature, and 0.029$\pm$0.001 (pCi/l)/(cph/Cell) at $50^{\circ}C$. Radon and its daughters concentrations were measured in a room air for the demonstrating purpose. The concentrations of 222 Rn, $^{218}Po,\;224\;Pb,\;and\;^{214}Bi$ were 0.87, 0.53, 0.35 and 0.26 pCi/l. The total eqilibrium factor was around 0.40 and the WL is $3.33{\times}10^{-3}$, resulting in 30 mrem/yr at this place.

  • PDF

Determination of Trace Lead by Laser Resonance Ionization Spectroscopy (I). Dependence of Detection Limit on Ionization Schemes (레이저 공명이온화에 의한 극미량 납의 정량 (I). 이온화 경로에 따른 검출한계의 변화)

  • Kyuseok Song;Jong Hun Lee;Jongmin Lee
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.6
    • /
    • pp.832-839
    • /
    • 1992
  • Lead has been determined by Resonance Ionization Mass Spectrometry (RIMS) through one-color-two-photon ionization, two-color-two-photon ionization and three-color-three-photon ionization in a vacuum chamber equipped with Time-of-Flight(TOF) mass spectrometer. In all cases, the first excited state chosen was 6p7s($^3P_1$) state and the transition was at 283.3 nm in wavelength from the ground state. By using various concentrations of lead standard solutions, the calibration curve is obtained in the range of 0.1 ${\mu}g$ to 1.0 pg in both ionization schemes. The detection limit was estimated as 20 pg for the two-color ionization, while 10 pg for the three-color ionization experiment.

  • PDF

The Measurement of Airborne Radon Daughter Concentrations in the Atmosphere (대기중(大氣中) 라돈 붕괴생성물(崩壞生成物)의 공기중(空氣中) 방사능(放射能) 농도(濃度)의 측정(測定))

  • Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.5-13
    • /
    • 1979
  • A simple method for determining the airborne concentration of radon daughter products has been developed, which is based on gross alpha counting of the air filter collections at several time intervals after completion of air sampling. The concentration of each nuclide is then obtained from an equation involving the alpha disintegrations, the sampling time, and the known numerical coefficients. The state of radioactive disequilibrium is also investigated. The atmosphere sampled in the TRIGA Mark-III reactor room was largely in disequilibrium. The extent of radioactive disequilibrium between radon daughter products seems likely depend on sampling times associated with turbulence conditions. The data obtained here will certainly provide useful information on the evaluation of internal exposure and calibration of effluent monitoring instruments.

  • PDF