• Title/Summary/Keyword: Energy calibration

Search Result 430, Processing Time 0.028 seconds

Energy Retrofit and Estimate for Small-to-Medium Office Buildings (중소규모 사무소건물의 에너지 개보수 방안 및 평가)

  • 정영선;허정호;방기영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.279-288
    • /
    • 2001
  • This paper is to derive energy retrofit strategies through energy audit and analysis for a selected small-to-medium office building located in Seoul, Korea,. To activate ESCO business in Korea, our final goal is to develope a simple and adequate energy retrofit procedure through computer simulation. Calibration process was fairly successful eve without the aid of tough field measurement. In terms of annual energy consumption, the percent difference between the predicted and the monitored values were within a reasonable tolerance of $\pm10$%. Based on the calibrated baseline model and the systematic investigation of target building, retrofit measures were suggested with two categories such as architectural side and equipment side. Both selected parametric and interactive retrofit measure simulations resulted in various energy saving quantities and cost, thus the priority among the measures were made. If we were to select the more realistic and reasonable retrofit measure in future, economic estimate were should be practiced with the life cycle cost analysis.

  • PDF

Calibration Equation for Nacelle Anemometer Derived by LIDAR Measurements (라이다 측정을 이용한 나셀 풍속계 보정식 제안)

  • Kim, Hyun-Goo;An, Hae-Joon;Yang, Seung-Joo;Park, Woo-Jae;Kim, Seok-Woo
    • New & Renewable Energy
    • /
    • v.9 no.1
    • /
    • pp.12-16
    • /
    • 2013
  • The nacelle anemometer mounted behind the blade roots of a wind turbine measures distorted wind speed comparable with free-stream wind because of the wake effects caused dependent upon the operation of the wind turbine and the rotation of its blades. The field campaign was carried out to measure free-stream wind speed at a height identical to the height of the nacelle anemometer by deploying a ground-based remote-sensing equipment, LIDAR. It is derived that a third-order polynomial equation for correcting wind speed measured by the nacelle anemometer to undistorted free-stream wind speed incident to a wind turbine. It is anticipated that the derived correction equation enables wind speed measured by the nacelle anemometer to be used as a precise input for a wind turbine performance test and for developing an active control logic.

Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements (한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교)

  • Chang, Si-Yeong;Kim, Bong-Hwan;Kim, Jang-Lyul;McDonald, J.C.;Murphy, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.255-262
    • /
    • 1996
  • This paper describes the results of intercomparison measurements of KAERI reference photon and beta radiation fields between the KAERI and the PNNL(Pacific Northwest National Laboratory), recently performed at KAERI radiation calibration and dosimetry laboratory on the basis of the ANSI N13.11 criteria for personal dosimeter performance test. Each laboratory used her own radiation detectors or measurement devices traceable to her national primary standard in measuring the exposure rates for photon fields, the absorbed dose rates for beta radiation fields. The agreements in reference radiation measurements between two laboratories were found to be less than ${\pm}2.0%$ for photon fields, ${\pm}1.0%$ for beta radiation fields. Therefore, it could be concluded that KAERI reference radiation fields comply well with the international standard and thus can further serve as a national basis for the researches and developments in radiation protection dosimetry in Korea.

  • PDF

SPECTRUM WEIGHTED RESPONSES OF SEVERAL DETECTORS IN MIXED FIELDS OF FAST AND THERMAL NEUTRONS

  • Kim, Sang In;Chang, Insu;Kim, Bong Hwan;Kim, Jang Lyul;Lee, Jung Il
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted response, the detector response functions of 17 neutron-measuring devices were numerically folded with each of the produced calibration neutron spectra through the in-house developed software 'K-SWR'. The detectors' response functions were taken from the IAEA Technical Reports Series No. 403 (TRS-403). The reference neutron fields of 21 kinds with 2 spectra groups with different proportions of thermal and fast neutrons have been produced using neutrons from the $^{241}Am$-Be sources held in a graphite pile, a bare $^{241}Am$-Be source, and a DT neutron generator. Fluence-average energy ($E_{ave}$) varied from 3.8 MeV to 16.9 MeV, and the ambient-dose-equivalent rate [$H^*(10)/h$] varied from 0.99 to 16.5 mSv/h.

Validation and Calibration of Semi-Quantitative Food Frequency Questionnaire - With Participants of the Korean Health and Genome Study - (반정량식품섭취빈도조사지의 타당성 검증 및 보정 - 지역사회 유전체 코호트 참여자를 대상으로 -)

  • Ahn, Youn-Jhin;Lee, Ji-Eun;Cho, Nam-Han;Shin, Chol;Park, Chan;Oh, Berm-Seok;Kimm, Ku-Chan
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.2
    • /
    • pp.173-182
    • /
    • 2004
  • We carried out a validation-calibration study of the food frequency questionnaire (FFQ) that we had previously developed for a community-based cohort of the Korean Genome and Health Study of the Korea National Genome Research Institute. We have collected a total of 254 3-day diet records (DRs) from 400 subjects, 200 each randomly selected from the two study cohorts of Ansung and Ansan. FFQ was administered at the time of cohort recruitment in 2001, and DRs were collected during a two month period from January through February of 2002. The mean age was 52.2 years. Farming for men and housewife for women were the most common occupations. The majority of the subjects had undergone 6∼12 years of education. The general characteristics including demographic and other data were not different from the total cohort subjects. Absolute levels of consumed nutrients including total energy (energy), protein, fat, carbohydrate, calcium, phosphorus, sodium, potassium, iron, retinol, carotene, vitamin A, thiamin, riboflavin, niacin and vitamin C were compared. The average of energy intake was not significantly different between the data collected by the 2 methods. However, consumptions of protein and fat were higher in data of DRs, whereas that of carbohydrate was higher in FFQ data. Significant correlation of each nutrient consumption between the data sets was observed (p < 0.05) except in the case of iron, while the average correlation coefficient between them was 0.22 ranging from 0.33 for energy to 0.11 for iron. The results of cross classification by quantile for exact classification ranged from 25.2% (carotene) to 35.0% (phosphorus), and from 64.6% (vitamin A) to 76.4% (retinol) for adjacent classification. The proportion of completely opposite classification was 8.1% in average. Calibration slope was estimated by regression and calibration parameters ranged from 0.025 for carotene to 0.423 for niacin. We conclude that the FFQ we have developed is an appropriate tool for assessing the nutrient intakes as ranking exposures in epidemiology studies in view that amounts of consumed nutrients obtained by FFQ were similar to those collected by DRs, that correlations between consumed nutrients collected by these methods were significant, and that classification results were relatively fair. The correlation coefficients, however, were lower than expected, which may be mainly due to the survey season. In fact, any short-term dietary survey cannot accurately reflect the overall dietary intakes that change heavily depending on seasons. Further studies including the analysis of chemical indices would be helpful for the studies of causal relationship between the diet and disease.

Operation Analysis of a Communication-Based DC Micro-Grid Using a Hardware Simulator

  • Lee, Ji-Heon;Kim, Hyun-Jun;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.313-321
    • /
    • 2013
  • This paper describes the operation analysis results of a communication-based DC micro-grid using a hardware simulator developed in the lab. The developed hardware simulator is composed of distributed generation devices such as wind power, photovoltaic power and fuel cells, and energy storage devices such as super-capacitors and batteries. Whole system monitoring and control was implemented using a personal computer. The power management scheme was implemented in a main controller based on a TMS320F28335 chip. The main controller is connected with the local controller in each of the distributed generator and energy storage devices through the communication link based on a CAN or an IEC61850. The operation analysis results using the developed hardware simulator confirm the ability of the DC micro-grid to supply the electric power to end users.

Conversion Factors for Calibration of Personnel Dosimeters (개인선량계 교정을 위한 환산인자 계산)

  • Lee, Won-Koo;Lee, Tae-Young;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 1991
  • MCNP code was used to calculate conversion factor H(d)ma at the depths of 0.07 and 10mm within a water phantom recommended by IAEA and within a PMMA phantom required by the US dosimeter proficiency testing programmes. The calculations were performed for an expanded parrallel beam of monoenergetic photons of perpendicular incidence on one faces of the phantom. The results can be used as conversion factor in calibrating individual dosemeters in terms of the dose equivalent quantities defined directly in the phantom.

  • PDF

The Field Test of Power Performance Measurement for U50 Wind Turbine (U50 풍력발전기 출력성능 실증연구)

  • Hwang, Jin-Su;Jang, Seong-Tae;Kim, Dae-Hyun;Bang, Jo-Hyug;Ryu, Ji-Yune
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.372-375
    • /
    • 2007
  • 750kW gearless type wind turbine, named U50, is developed by UNISON in Korea. The newly developed wind turbine should be evaluated the power curve and the estimated annual energy production by following international standard to verify the power performance characteristics. This paper shows the test and evaluation procedure according to IEC 61400-12-1 which specifies a procedure of measuring the power performance characteristics of a single wind turbine and applies to the testing of wind turbines of all types and sized connected to the electrical power network. And this paper also shows the power performance characteristics for U50 wind turbine which is determined in accordance with IEC regulation.

  • PDF

A Non-contact Shape Measuring System Using an Artificial Neural Network

  • Jeong, Woo-tae;Lee, Myung-Chan;Koh, Duck-joon;Cho, Hyung-suck
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.399-404
    • /
    • 1996
  • We developed a non-contact shape measuring device using computer image processing technology. We present a method of calibrating a CCD video camera and a laser range finder which is the most important step toward making an accurate shape measuring system. An artificial neural network is used for the calibration. Our measurement system is composed of a semiconductor laser. a CCD video camera, a personal computer, and a linear motion table. We think that the developed system could be used for measuring the change in shape of the spent nuclear fuel rod before and after irradiation which is one of the most important tasks for developing a better nuclear fuel. A radiation shield is suggested for the possible utilization of the range finder in radioactive environment.

  • PDF

Development of Dual-mode Signal Processing Module for Multi-slit Prompt-gamma Camera (다중 슬릿 즉발감마선 카메라를 위한 이중모드 신호처리 모듈 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Sung Hun;Kim, Chan Hyeong;Shin, Dong Ho;Lee, Se Byeong;Jeong, Jonh Hwi
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • In proton therapy, in vivo proton beam range verification is very important to deliver conformal dose to the target volume and minimize unnecessary dose to normal tissue. For this purpose, a multi-slit prompt-gamma camera module made of 24 scintillation detectors and 24-channel signal processing system is under development. In the present study, we have developed and tested a dual-mode signal processing system, which can operate in the energy calibration mode and the fast data acquisition mode, to process the signals from the 24 scintillation detectors. As a result of performance test, using the energy calibration mode, we were able to perform energy calibration for the 24 scintillation detectors at the same time and determine the discrimination levels for the detector channels. Further, using the fast data acquisition mode, we were able to measure a prompt-gamma distribution induced by a 45 MeV proton beam. The measured prompt gamma distribution was found similar to the proton dose distribution at the distal fall-off region, and the estimated beam range was $17.13{\pm}0.76mm$, which is close to the proton beam range of 16.15 mm measured by an EBT film.