• 제목/요약/키워드: Energy balance

검색결과 1,584건 처리시간 0.033초

Comparison of Daily Soil Water Contents Obtained by Energy Balance-Water Budget Approach and TDR

  • Rim, Chang-Soo
    • Korean Journal of Hydrosciences
    • /
    • 제8권
    • /
    • pp.57-68
    • /
    • 1997
  • The daily soil water contents were obtained from the time domain reflectometry(TDR) method and energy balance-water budget approach with eddy correlation at the two small semiarid watersheds of Lucky Hills and Kendall during the summer rainy period. There was a comaprison of daily soil water content measured and estimated from these two different approaches. The comparison is valuable to evaluate the accuracy of current soil water content measuring system using TDR and energy balance-water budget approach using eddy correlation method at a small watershed scale. The degree of simiarity between the regressions of these two methods of measuring soil water content was explained by determining the correlations between these methods. Simple linear regression analyses showed that soil water content measured from TDR method was responsible for 58% and 63% of the variations estimated from energy balance-water budget approach with edy correlation at Lucky Hills and Kendall, respectively. The scatter plots and the regression analyses revealed that two different approaches for soil water content measurement at a small watershed scale have no significant difference.

  • PDF

액체로켓엔진 통합 설계를 위한 에너지 발란스 프로그램 개발 (Development of Energy Balance Program for Staged-Combustion Cycle of Liquid Rocket Engine)

  • 이상복;노태성
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.93-97
    • /
    • 2010
  • 액체로켓엔진 단계식 연소 사이클에 대한 에너지 발란스 프로그램을 개발하였다. 엔진을 추력실, 터보펌프, 터빈, 예연소기, 공급계 부품 등으로 모듈화 하여 각 모듈 프로그램을 제어하는 방식을 사용하였다. 이를 통해 에너지, 질유량, 압력의 균형을 맞추었으며 대표적인 단계식 연소 사이클인 스페이스 셔틀 메인 엔진의 자료를 바탕으로 비교 검증하였다.

  • PDF

Research on Carried-Based PWM with Zero-Sequence Component Injection for Vienna Type Rectifiers

  • Ma, Hui;Feng, Mao;Tian, Yu;Chen, Xi
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.560-568
    • /
    • 2019
  • This paper studies the inherent relationship between currents and zero-sequence components. Then a precise algorithm is proposed to calculate the injected zero-sequence component to control the DC-Link neutral-point voltage balance, which can result in a more efficient and flexible neutral point voltage balance with a desirable performance. In addition, it is shown that carried-based PWM with the calculated zero-sequence component scheme can be equivalent to space-vector pulse-width modulation (SVPWM). Based on the proposed method, the optimal zero-sequence component of the feasible modulation indices is analyzed. In addition, the unbalanced load limitation of the DC-Link neutral-point voltage balance control is also revealed. Simulation and experimental results are shown to verify the validity and practicality of the proposed algorithm.

A Modification of Departure from Nucleate Boiling Model Based on Mass, Energy, and Momentum Balance For Subcooled Flow Boiling in Vertical Tubes

  • Sul, Young-Sil;Lee, Kwang-Won;Ju, Kyong-In;Cheong, Jong-Sik;Yang, Jae-Young
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.108-113
    • /
    • 1996
  • Several analytical models for the departure from nucleate boiling (DNB) phenomenon have been developed during the last decade. Among these, Chang & Lee's model based on a bubble crowding mechanism is remarkable in the fundamental features characterized as the formulation of mass, energy, and momentum balance equation at thermal-hydraulic conditions leading to the DNB. However, Bricard and Souyri remarked that the assumption of stagnant bubbly layer at the DNB condition is questionable and the signs on the axial projections of the momentum fluxes at the core/bubbly layer interface in the momentum balance equations are erroneous. From this remark, Chang & Lee's model has been re-examined and modified by correcting the erroneous treatments in the momentum balance equations and removing the spurious assumptions. The revised model predicts well the extensive DNB data of water in uniformly heated tubes at low qualities and shows more accurate prediction compared with the original model.

  • PDF

Energy Balance and Power Performance Analysis for Satellite in Low Earth Orbit

  • Jang, Sung-Soo;Kim, Sung-Hoon;Lee, Sang-Ryool;Choi, Jae-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권3호
    • /
    • pp.253-262
    • /
    • 2010
  • The electrical power system (EPS) of Korean satellites in low-earth-orbit is designed to achieve energy balance based on a one-orbit mission scenario. This means that the battery has to be fully charged at the end of a one-orbit mission. To provide the maximum solar array (SA) power generation, the peak power tracking (PPT) method has been developed for a spacecraft power system. The PPT is operated by a software algorithm, which tracks the peak power of the SA and ensures the battery is fully charged in one orbit. The EPS should be designed to avoid the stress of electronics in order to handle the main bus power from the SA power. This paper summarizes the results of energy balance to achieve optimal power sizing and the actual trend analysis of EPS performance in orbit. It describes the results of required power for the satellite operation in the worst power conditions at the end-of-life, the methods and input data used in the energy balance, and the case study of energy balance analyses for the normal operation in orbit. Both 10:35 AM and 10:50 AM crossing times are considered, so the power performance in each case is analyzed with the satellite roll maneuver according to the payload operation concept. In addition, the data transmission to the Korea Ground Station during eclipse is investigated at the local-time-ascending-node of 11:00 AM to assess the greatest battery depth-of-discharge in normal operation.

High Efficiency Alternating Current Driver for Capacitive Loads Using a Current-Balance Transformer

  • Baek, Jong-Bok;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제11권1호
    • /
    • pp.97-104
    • /
    • 2011
  • This paper proposes a new alternating current driving method for highly capacitive loads such as plasma display panels or piezoelectric actuators, etc. In the proposed scheme, a current balance transformer, which has two windings with the same turn-ratio, provides not only a resonance inductance for energy recovery but also a current balance among all of the switching devices of the driver for current stress reduction. The smaller conduction loss than conventional circuits occurs due to the dual conduction paths which are parallel each other in the current balance transformer. Also, the leakage inductances of the transformer are utilized as resonant inductors for energy recovery by the series resonance to the capacitive load. Furthermore, the resonance contributes to the small switching losses of the switching devices by soft-switching operation. To confirm the validity of the proposed circuit, prototype hardware with a 12-inch mercury-free flat fluorescent lamp is implemented. The experimental results are compared with a conventional energy-recovery circuit from the perspective of luminance performances.

Evapotranspiration Estimation Study Based on Coupled Water-energy Balance Theory in River Basin

  • Xue, Lijun;Kim, JooCheol;Li, Hongyan;Jung, Kwansue
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.146-146
    • /
    • 2018
  • Basin evapotranspiration is the result of water balance and energy balance, which is affected by climate and underlying surface characteristics, the process is complex, and spatial and temporal variability is large, the evapotranspiration estimation of river basin is an important but difficult problem in the field of hydrology, over the years, many scholars devoted to the basin actual evapotranspiration estimation and achieved excellent results. We discuss Budyko coupled water-energy balance theory and evaporation paradox, then use the Fu's equation to estimate actual evapotranspiration yearly in different areas with different dryness. The result shows that Fu's equation has high precision for estimating evapotranspiration yearly in our selected study area, and the estimation result has higher precision in the area with high dryness. Then, we propose an improved formula which can be used to estimate actual evapotranspiration monthly. Furthermore, we found that the parameter in the formula reflects general conditions of underlying surface and it is affected by several factors, at last, we tried to propose the calculation formula. The study indicates that Fu's equation provides a reliable method for evapotranspiration estimation in dry regions as well as semi-humid and semi-arid regions, which has great significance for forecasting river basin water resources and inquiring into ecological water requirement.

  • PDF

한국과 IEA 에너지밸런스 표의 비교 분석연구 (2009년도를 중심으로) (Comparative Analyses of Korean Energy Balance Tables from KEEI and IEA (in 2009))

  • 손중찬;김수덕
    • 자원ㆍ환경경제연구
    • /
    • 제24권1호
    • /
    • pp.109-139
    • /
    • 2015
  • 현행 국가통계인 에너지밸런스 표는 우리나라 에너지 부문의 현황파악의 기초지표임에도 불구하고 IEA 기준의 에너지밸런스 표와 체계 및 수치상의 큰 차이가 있다는 선행연구를 근거로, 본 연구에서는 서로 다른 통계체계를 갖는 2009년 에너지경제연구원(KEEI) 기준의 에너지밸런스 표와 국제에너지기구(IEA) 기준의 에너지밸런스 표의 비교를 위한 기초적인 틀을 마련하고, 그 구체적인 차이를 백분율 값으로 비교 분석하여 보았다. 에너지원별, 세부 용도별로 그 구체적인 차이를 산정해 본 결과, 1차에너지공급과 에너지전환에서 에너지유가 32% 이상의 큰 차이가 나타났고, 최종에너지소비에서는 비에너지의 납사가 석유 화학에서 14.58%의 차이를 보이고 있는 등 최종에너지소비 기준으로 KEEI 에너지밸런스 통계가 IEA 통계에 비해 3.58% 크게 나타남을 확인하였다. 에너지통계는 이를 기반으로 하는 연구 및 정책 결정에 중요한 기초자료가 된다는 점에서 추가 연구와 개선을 위한 대책 마련이 필요해 보인다.

한국인 수유부의 체조성 변화 및 에너지 평형 (Maternal Changes of Body Composition and Energy Balance in Korean Lactating Women)

  • 임현숙
    • Journal of Nutrition and Health
    • /
    • 제29권8호
    • /
    • pp.899-907
    • /
    • 1996
  • This study was conducted to examine how Korean women mange energy metabolism during lactation. Eighteen women recruited were healthy, had normal pregnancies and were required to breast-feed their babies exclusively for at least 12wks. During the study period, all subjects were visited and interviewed five times : 3d, 9d, 4wk, 8wk, and 12wk lactation. Body composition variables were analyzed by a bioelectrical impedance method, energy intakes were assessed by using the inventory-weighing method, energy expenditure were determined by recording daily activities, and milk energy output was investigated from the amount of milk production and the gross energy content of milk. The subjects consumed less energy than current recommended allowance all over the study period, but compatible with fairly adequate lactational performance. They responded the additional energy stress of lactation by enhancing metabolic efficiency, increasing energy intakes, reduction physical activities and mobilizing body reserves. Another finding in this study was that the reduction in body fat-free mass may be the one way that women meet the energy demands of lactation like the reduction in body fat mass. The results from this study suggest that current recommended additional energy need during lactation, 2.09MJ/d(500kcal/d), is too high for healthy Korean women. Our data also indicate that the changes of body composition and energy balance at earlier postpartum are extremely different from those at later periods.

  • PDF

Energy-based seismic design of structures with buckling-restrained braces

  • Kim, Jinkoo;Choi, Hyunhoon;Chung, Lan
    • Steel and Composite Structures
    • /
    • 제4권6호
    • /
    • pp.437-452
    • /
    • 2004
  • A simplified seismic design procedure for steel structures with buckling-restrained braces (BRB) was proposed based on the energy balance concept and the equal energy assumption. The input seismic energy was estimated from a design spectrum, and the elastic and hysteretic energy were computed using energy balance concept. The size of braces was determined so that the hysteretic energy demand was equal to the hysteretic energy dissipated by the BRB. The validity of using equivalent single-degree-of-freedom systems to estimate seismic input and hysteretic energy demand in multi story structures with BRB was investigated through time-history analysis. The story-wise distribution pattern of hysteretic energy demands was also obtained and was applied in the design process. According to analysis results, the maximum displacements of the 3-story structure designed in accordance with the proposed procedure generally coincided with the target displacements on the conservative side. The maximum displacements of the 6- and 8-story structures, however, turned out to be somewhat smaller than the target values due to the participation of higher vibration modes.