• 제목/요약/키워드: Energy and Consumption

검색결과 6,332건 처리시간 0.031초

A Case Study on Energy Consumption and Calibration of Green Remodeling Buildings (그린리모델링 건물에 대한 에너지소비량 및 보정 사례연구)

  • Kim, Dongi;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • 제40권5호
    • /
    • pp.47-58
    • /
    • 2020
  • Ministry of Land, Infrastructure and Transport(MOLIT) has increased reduction rate from 18.1% to 32.7% in Building sector compared to BAU of the national greenhouse gas emission according to the 2030 Greenhouse Gas Reduction Road map Amendment. For this purpose, MOLIT has been activating the green remodeling projects for existing buildings. Considering that 15 year old buildings after completion are 74% (5.25 million buildings) among about 7 million existing building stocks in Korea, reduction of building energy consumption by green remodeling is urgently needed, However, it is a major difficulty of activation for green remodeling projects because there are few case studies on Before and After building energy consumption of actual green remodeling projects. Considering that building energy performance and value increase after green remodeling through previous researches, additional studies of the energy consumption assessment on actual green remodeling projects are essential. Therefore, this study aims to propose results on Before and After building energy consumption of actual green remodeling projects.

Analysis of Energy Performance & Energy Saving with Geothermal Heat Pump System Using TRNSYS Program in a Large Scale Shopping Store (TRNSYS 프로그램을 이용한 대형쇼핑매장 에너지성능해석 및 지열시스템을 도입하는 경우 에너지절약 특성분석)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제29권1호
    • /
    • pp.47-56
    • /
    • 2015
  • Energy consumption in buildings is currently a real problem. That is why both assessment of energy performance and effective energy management including renewable energy system are essential. Thus, this paper focuses on a case study to analyze the energy performance and cooling & heating energy saving of a large scale shopping store in Daejeon city. The reference building is simulated by using TRNSYS dynamic simulation tool to examine its annual energy consumption. For annual energy analysis of building, one year energy consumption is surveyed in the field. The related study is carried out in large scale shopping store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and other. The evaluation of energy performance of the geothermal heat pump system installed in a large scale shopping store is also analyzed by TRNSYS tool. From simulation results, it evaluated that the geothermal heat pump system is effective energy savings method in large scale shopping store.

Comparison of Cooling-Energy Performance Depending on the Economizer-Control Methods in an Office Building (이코노마이저 제어 방법에 따른 사무소 건물의 냉방 에너지 성능 비교)

  • Son, Jeong-Eun;Hyun, In-Tak;Lee, Jea-Ho;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제27권8호
    • /
    • pp.432-439
    • /
    • 2015
  • Current building procedures seek to minimize external air supplies to reduce the energy consumption of air conditioning, resulting in a high dependency on mechanical ventilation. We therefore studied an economizer-cycle system, whereby the introduction of external air saves energy. We analyzed different economizer-control methods, addressing mixed-air temperatures and outdoor-air fractions according to outdoor-air temperatures; also, we analyzed the energy consumption of the three economizer-cycle control types using detailed EnergyPlus simulation modeling. A differential enthalpy control method showed a lower energy consumption range from 5.8% to 6.2% than that of other methods during the simulated period. A differential dry-bulb control method showed a 12.7% lower energy consumption than the no-economizer method in the intermediate period, but also showed 7.1% more energy consumption during the summer period. When latent heat was not removed due to high summer humidity, we found a significant level of resultant energy consumption.

Analysis of New & Renewable Energy Application and Energy Consumption in Public Buildings (공공건축물의 신재생에너지 적용과 에너지 사용량 분석)

  • Lee, Yong-Ho;Seo, Sang-Hyun;Kim, Hyung-Jin;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • 제32권3호
    • /
    • pp.153-161
    • /
    • 2012
  • This study conducted a survey and field investigation on the application of the Public Obligation System for new & renewable energy in public buildings, as well as energy consumption of each building according to their uses. The findings are as follows: (1) Since the introduction of the Public Obligation System (until June 30, 2011), there was average 1.4 new & renewable energy facilities established at 1,433 places. Preference for solar energy facilities was the highest at 57.8%. (2) The revised act sets the obligatory supply percentage of new & renewable energy for each public building: it is 9.0% for a tax office, 4.2% for a dong office, 8.2% for a public health center, and 12.6% for a fire station. All the public buildings except for fire stations failed to meet 10% expected energy consumption, a revised standard. (3) Energy consumption of each public building was 120.6TOE for a tax office, 124.3TOE for a dong office, 166.4TOE for a public health center, and 174.6TOE for a fire station. The energy consumption was comprised of 80% electric power, 18% urban gas, and 1% oil. (4) Electric power consumption per person in the room was high at a dong office, and fuel consumption per person in the room was high at a public health center. In addition, electric power consumption per unit space was high at a public health center, and fuel consumption per unit space was high at a fire station. (5) In all the four public buildings, power load had the highest basic unit percentage at average 55%, being followed by heating load (21.2%), cooling load (15%), and water heating load (7%). A tax office and fire station had 2% load due to cooking facilities.

The Relationship Between Income Inequality and Energy Consumption: A Pareto Optimal Approach

  • NAR, Mehmet
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권4호
    • /
    • pp.613-624
    • /
    • 2021
  • This paper analyzes the relationship between income distribution and energy consumption from a Pareto optimal approach. For this purpose, the causality relationship between electricity consumption per capita (kWh) with respect to country groups and energy consumption per capita (kg of oil equivalent) along with gross domestic product per capita was analyzed. In addition to this purpose, a Pareto analysis was conducted to determine the countries with the highest per capita national income, how much of the world total energy they consume, and whether the law of power in the energy and electricity markets exists. Finally, the impact of official development assistance provided to low-income countries by high-income countries on the low-income countries' electricity and energy consumption was analyzed. In other words, it was questioned whether pareto redistribution policies serve the purpose or not. The Engle-Granger causality approach was used in the analysis of the causality relationship between variables. Our analysis indicated that, first, the energy data of the country groups may be inadequate in revealing income inequalities. Second, the existence of Pareto law of power and global income inequality can be explained based on energy data. Finally, Pareto optimal redistribution policies to eliminate income inequality remain inadequate in practice.

A Study on the Evaluation of Lighting Energy Consumption by Control Strategy of the Electric Lighting (전기조명 제어 전략에 따른 조명에너지 소비량 평가에 관한 연구)

  • Yun, Gyeong;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.119-125
    • /
    • 2012
  • The objective of this study is to evaluate the electric lighting energy consumption carried out by Daysim program. A comparison between the measurement and simulated exterior global horizontal illuminance shows differences about 10% and it is very similar to the measurement. The interior illuminance simulated by Daysim are 18.9% lower than the measurement and simulated lighting energy consumption is 10% lower than the measurement. Corrected annual lighting energy simulation results show that the best case is the combination of occupancy switch-off and dimming system with automatic controlled blinds (E-3). In case of no blinds, it occasionally derives the minimum lighting energy consumption but it causes the glare, so we need to be careful for choosing the control strategy. For the overcast sky, the lighting energy consumption is not changed significantly by control strategy while the lighting energy in the clear sky is changed noticeably. So we must know the right strategy for each case to control the electric lights and blinds.

클린룸과 실험실이 있는 사무용 건물의 에너지 소비 실태 측정 및 분석

  • 김성실;양시선;김영일;김석현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제13권10호
    • /
    • pp.966-973
    • /
    • 2001
  • In this study, measurement and analysis of energy consumption of an office building with cleanroom and laboratory have been conducted. Data acquisition system for collecting energy consumption data of the whole building including air-conditioning equipments has been installed in a building located in Seoul. Data are collected for a period of one year in 2000 and analyzed for studying the energy consumption pattern. The percentage of electrical energy used for air-conditioning system is measured to be 46.1%. The collected data will serve as valuable information for diagnosing and improving the energy system of the building.

  • PDF

Estimation Model of Electric Energy Consumption on Logistics Center Based on Thermodynamics Theory (열역학 이론 기반의 물류센터 전기에너지 소비량 산출 모형)

  • Cui, Lian;Kim, Young-Joo;Kim, Cheolsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제16권10호
    • /
    • pp.6799-6806
    • /
    • 2015
  • Electric energy consumption is always followed by the introduction of diversity scale-up and state-of-the-art equipments in logistic centers. In order to analyze the status and the characteristic of the electric energy consumption quantitatively, and also to evaluate the efficiency of the electric energy, this research aims to develop an estimation model of standard electric energy consumption for logistic centers. The proposed model applies the thermodynamics theory so as to effectively reflect the peculiarity that the temperature in the logistic center influences the electric energy consumption. And the model consists of the energy consumed by the refrigerator, which can be subdivided into the heat conducted through the wall, the heat convected by the open doors and the heat lost into the goods, and the electric consumption of the machinery equipments. The model also includes a variety of explanatory variables to support an operator of logistics centers in evaluating the efficiency of energy consumption and establishing improvement strategies for energy efficiency. Application of the model developed in this study is discussed with observed data on energy consumption of a logistics center.

Minimizing Energy Consumption in Scheduling of Dependent Tasks using Genetic Algorithm in Computational Grid

  • Kaiwartya, Omprakash;Prakash, Shiv;Abdullah, Abdul Hanan;Hassan, Ahmed Nazar
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.2821-2839
    • /
    • 2015
  • Energy consumption by large computing systems has become an important research theme not only because the sources of energy are depleting fast but also due to the environmental concern. Computational grid is a huge distributed computing platform for the applications that require high end computing resources and consume enormous energy to facilitate execution of jobs. The organizations which are offering services for high end computation, are more cautious about energy consumption and taking utmost steps for saving energy. Therefore, this paper proposes a scheduling technique for Minimizing Energy consumption using Adapted Genetic Algorithm (MiE-AGA) for dependent tasks in Computational Grid (CG). In MiE-AGA, fitness function formulation for energy consumption has been mathematically formulated. An adapted genetic algorithm has been developed for minimizing energy consumption with appropriate modifications in each components of original genetic algorithm such as representation of chromosome, crossover, mutation and inversion operations. Pseudo code for MiE-AGA and its components has been developed with appropriate examples. MiE-AGA is simulated using Java based programs integrated with GridSim. Analysis of simulation results in terms of energy consumption, makespan and average utilization of resources clearly reveals that MiE-AGA effectively optimizes energy, makespan and average utilization of resources in CG. Comparative analysis of the optimization performance between MiE-AGA and the state-of-the-arts algorithms: EAMM, HEFT, Min-Min and Max-Min shows the effectiveness of the model.

Development of an Evaluation Method and Support Policy for the Green Home Project (친환경주택평가기법개발 및 지원방안에 관한 연구)

  • Lee, Jong-Sung;Yoo, Jung-Hyun;Rhim, Joo-Ho;Kim, Hyo-Jin
    • Land and Housing Review
    • /
    • 제1권1호
    • /
    • pp.27-34
    • /
    • 2010
  • The energy consumption of residential sectors is given a sizable portion in total energy consumption. So, improvement of building performance can be as a part of principal energy strategy. For this reason, an evaluation tool for estimation of energy consumption was developed and supportive policies were considered in this study. In particular, energy saving technology were examined to practice the green home project, among them 7 items were selected as a factor for estimating energy consumption. In addition, to the simulation study on energy consumption, heating load, hot water demand and electric consumption was also studied with actual measured value. Further more, several supportive policies were discussed to encourage green home project in Korea.