• 제목/요약/키워드: Energy Use Monitoring

검색결과 264건 처리시간 0.03초

울돌목 시험조류발전소 구조물 안전감시시스템 구축에 관한 연구 (Study on Building a Structural Health Monitoring System for Uldolmok Tidal Current Power Plant)

  • 이진학;박우선;박진순;이광수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.635-638
    • /
    • 2007
  • In this paper, we described the fundamental concepts of proposed structural health monitoring system for Uldolmok Tidal Current Power Plant focusing on the use of smart sensors including fiber bragg grating sensors and macro fiber composite sensors. The structural health monitoring system can play an important role to maintain the structural safety for offshore structures like as bridges and high-rise buildings. In the case of tidal current power plant, the monitoring system is much more important since the structures are usually constructed at the site with severer environmental loadings such as high current speed.

  • PDF

IoT 기반 주택형 건물 에너지 모니터링 시스템 설계 (Design of IoT-based Energy Monitoring System for Residential Building)

  • 이민구;정경권
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1223-1230
    • /
    • 2021
  • 최근 에너지 자원관리는 전 세계적인 주요 관심사이다. 에너지원 생산의 한계 조건 속에서, 효과적인 에너지 관리 활동은 에너지 수요 및 생산을 최소화하고 이는 환경이 미치는 영향을 최소화할 수 있다. 본 논문은 주거형 건물에서 에너지 소비자에게 전기 사용에 대한 실시간 정보를 제공할 수 있는 가정용 전기에너지 모니터링 시스템의 프로토타입 설계를 제안하고자 한다. 제안된 시스템은 자체 개발된 센싱 시스템, 데이터처리시스템, 원격 모니터링 서버 시스템으로 구성된다. 주거형 건물내에 설치 적용된 센싱 시스템은 전원 공급을 제어하는 릴레이, 부하 전기기기의 전류를 감지하는 CT센서, Kmote로 구성된 무선 스마트 플러그로 구성된다. 공동/단독 주거형 건물에서 3개월 동안의 가전제품별 에너지 소비량 데이터를 분석하여 제시하였으며, 실험결과는 에너지 소비 패턴과 현황을 추정할 수 있는 가능성을 확인하여 제시하고 있다.

전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링 (Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module)

  • 정득일;손영대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

무선 센서 네트워크에서 행위 기반 공격 탐지를 위한 감시 노드의 연결성과 일반 노드의 커버리지 분석 (Analysis of the Connectivity of Monitoring Nodes and the Coverage of Normal Nodes for Behavior-based Attack Detection in Wireless Sensor Networks)

  • 정균락
    • 한국컴퓨터정보학회논문지
    • /
    • 제18권12호
    • /
    • pp.27-34
    • /
    • 2013
  • 무선 센서 네트워크에서 센서들은 획득한 정보를 관리 노드로 전달하기 위해 서로 통신을 해야 하므로 공격에 취약한데 쓰레기 패킷 주입 같은 공격은 기존의 암호화 같은 방식을 사용해서는 퇴치하기 어렵다. 그래서 행위 기반 탐지가 대두되었는데 특정 감시 노드들이 이웃한 일반 노드의 통신을 감청하여 불법적인 패킷을 탐지하게 된다. 감시 노드들은 일반 노드들에 비해 더 많은 에너지를 사용하기 때문에 최소의 감시 노드들로 전체 또는 최대한 넓은 범위의 네트워크를 커버하는 것이 필요하다. 감시 노드는 일반 노드 중에서 선택될 수도 있고 일반 노드와 서로 다른 종류일 수도 있다. 본 연구에서는 서로 다른 종류의 감시 노드와 일반 노드가 배치되었을 때 커버되는 일반 노드의 수가 최대가 되도록 주어진 수의 감시 노드를 선택하는 알고리즘을 개발하고, 감시 노드의 수와 전송 범위가 감시 노드의 연결 비율과 일반 노드의 커버리지에 어떤 영향을 미치는 지 실험을 통해 비교하였다.

태양 에너지 기반 무선 센서 노드를 위한 에너지 예측 모델의 설계 (Design of Energy Prediction Model for Solar-Powered Wireless Sensor Nodes)

  • 나양타이 불간바트;공인엽
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.858-861
    • /
    • 2012
  • 무선 센서 네트워크를 이용한 응용들 중 특히 환경 모니터링을 위해 대량으로 배치된 센서 노드들은 배터리 교체가 어렵고 교체시에 비용이 많이 드는 단점이 있다. 이를 보완하기 위해서는 무선 센서 네트워크 주위에 존재하는 신재생 에너지를 이용할 필요가 있다. 신재생 에너지들 중 태양 에너지는 매일 사용할 수 있고 에너지의 밀도가 다른 에너지원들 보다 높아 많이 이용되고 있다. 이에 본 논문은 태양 에너지를 충전하여 지속적으로 동작할 수 있는 무선 센서 노드의 에너지 충전 및 방전 특성을 모델링하여 무선 센서 노드의 에너지 활용 형태를 예측할 수 있는 이론적 모델을 제안한다. 개선된 모델에 의해 예측된 결과와 실제 무선 센서 노드의 에너지 활용 패턴을 비교 분석함으로써 실제와 유사하게 모델링할 수 있다.

  • PDF

독립형 태양광 발전 시스템을 위한 저가의 다중 무선 모니터링 기법에 관한 연구 (A Study of Multiplex RE Monitoring Method of Low-Price for Stand-Alone PV Power Generation System)

  • 오진석;곽준호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.579-586
    • /
    • 2005
  • Recently, it has demanded to the wireless monitoring system in stand-alone PV power generation system. We propose the multiplex monitoring method using RF unit of low-price. RF unit consists of RF modem and communication controller. It is also able to use by repeater to communicate long distance. In this paper. two algorithms were programmed by CCS-C and C++ for multiplex monitoring method, The algorithm of choosing unit was used 'select and poll method' and the course assignment algorithm was embodied with 'Bellman-Ford algorithm'. The good result was achieved in the actual test without communication-data lose. The proposed method will be applied such as monitoring system of PV light on the wayside, monitoring system of unmanned lighthouse, monitoring system of refrigeration container on vessel and so on. It can be applied in the field that various ocean energy system.

WiSeMote: a novel high fidelity wireless sensor network for structural health monitoring

  • Hoover, Davis P.;Bilbao, Argenis;Rice, Jennifer A.
    • Smart Structures and Systems
    • /
    • 제10권3호
    • /
    • pp.271-298
    • /
    • 2012
  • Researchers have made significant progress in recent years towards realizing effective structural health monitoring (SHM) utilizing wireless smart sensor networks (WSSNs). These efforts have focused on improving the performance and robustness of such networks to achieve high quality data acquisition and distributed, in-network processing. One of the primary challenges still facing the use of smart sensors for long-term monitoring deployments is their limited power resources. Periodically accessing the sensor nodes to change batteries is not feasible or economical in many deployment cases. While energy harvesting techniques show promise for prolonging unattended network life, low power design and operation are still critically important. This research presents the WiSeMote: a new, fully integrated ultra-low power wireless smart sensor node and a flexible base station, both designed for long-term SHM deployments. The power consumption of the sensor nodes and base station has been minimized through careful hardware selection and the implementation of power-aware network software, without sacrificing flexibility and functionality.

스마트그리드 연계 고객전기설비 전기안전 실시간 감시 및 관리 방안 (Real Time Monitoring and Management Method for Electrical Safety of Customer Electrical Installations Connected to Smart Grids)

  • 전정채;박찬엄;임용배;배석명
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.340-344
    • /
    • 2010
  • In order to achieve purpose of Smart Grids, which is effective use of electrical energy, the safety of electrical installations must be secured. This paper presented real time monitoring and management method for electrical safety of customer electrical installations connected to Smart Grids. And the direction of electrical safety system for the introduction of real time monitoring and management method was suggested. Efficiency improvement of electrical safety management and new supplementary services related with Smart Girds will be available by introducing the presented method.

유헬스케어 패치형 무선 체온 모니터링 시스템 구현 (U-Healthcare Patch Type Wireless Body Temperature Monitoring System)

  • 박영상;권오언;조현성;손재범
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권1호
    • /
    • pp.55-61
    • /
    • 2020
  • Recently, there have been many research on fever management using u-healthcare technology. Especially, fever of infants requires continuous monitoring of body temperature by parents. For infants between 4 weeks and under 5 years old, it is recommended to use an electronic thermometer or chemical thermometer in the axilla, or to use an infrared thermometer. However, in order to overcome the reality of not being able to waste significant time on continuous monitoring, there have been demands of patch type thermometers with the internet of things (IoT) and wireless communication technologies. Existing IoT thermometers are difficult to attach to infants' body because they do not take into account its size, and their interoperability is not guaranteed because they do not comply with standards in communication. Therefore, in this study, a patch-type thermometer with a diameter of 20 mm and a weight of 2.9 g was developed to manage the fever of infants, while it communicates wirelessly with Bluetooth Low Energy (BLE) communication protocol and complies with IEEE 11073 PHD(Personal Health Device) at the same time. We verified its performance under the requirements of thermometers regulated by the Korean Ministry of Food and Drug Safety.

초고층 건물 커미셔닝에 따른 에너지 절감 효과 예측 (Prediction of Energy Saving Effects by Commissioning of High-Rise Building)

  • 조현;김효준;류성룡;조영흠
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.30-35
    • /
    • 2018
  • In this study, the energy commissioning was conducted for high-rise buildings(manual control). First of all, we conducted monitoring the energy use of buildings (electricity, heating, etc.), a commissioning improvement (automatic control) was proposed for each system. In addition, energy simulation was conducted to predict the effectiveness of the reform measures. As a result, terminal units control the greatest energy saving effect, If we applied all the improvements, we could save about 20% less than traditional energy usage, and it turned out that $CO_2$ emissions were reduced by about 19% when converted to $CO_2$.