• 제목/요약/키워드: Energy Savings

검색결과 573건 처리시간 0.027초

외기 도입에 따른 바닥급기 시스템의 에너지 사용량 분석 (Analysis of the Energy Consumption in Underfloor Air Distribution System depending on Outdoor Air Intake Rates)

  • 김동희;허정호;조동우;유기형;유지용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.826-831
    • /
    • 2006
  • In this paper, we discussed the energy performance of underfloor air distribution(UFAD) and overhead air distribution system according to outdoor air intake rates in a office building. For this, the laboratory(S lab.) is selected for measuring the thermal environments of UFAD system and overhead system. Based on the measured data, the TRNSYS simulation is used to evaluate the energy performance of UFAD system and the overhead system according to outdoor air intake rates. By increasing outdoor air intake rates from required outdoor air intake rates(100CMH) to maximum air intake rates, the energy savings of UFAD system comparing with overhead system are varied $15%{\sim}25.6%$ in summer, $12.8%{\sim}19%$ in fall/spring and not varied in winter(8%). As results of simulations on stratification height and cooling set temperature, the lower the stratification height and the higher cooling set temperature, the larger cooling energy savings of UFAD comparing with overhead system according to outdoor air intake rates.

  • PDF

Alternative Strategies to Central Heating Ventilation and Air Conditioning

  • Shrestha, Pramen P.;Prgada, Mythili
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.401-407
    • /
    • 2022
  • Central heating, ventilation and air conditioning (HVAC) is one of the largest consumers of energy in the residential sector. This project explores the use of multiple HVAC units and/or Zoning in a single residence to reduce energy loads. The energy consumption data of a detached single-family home using two HVAC units, one primary for the main house and a secondary HVAC for a casita, was collected for the same month for two consecutive years, along with details related to the outdoor temperature and the square footage being air-conditioned by each HVAC. A regression algorithm was trained using the above details to find the relation between the parameters. Next, based on the occupancy and usage patterns, the HVAC was redesigned assuming more area under the secondary HVAC unit. The trained algorithm was then used to make energy usage predictions for the revised primary HVAC area, with the assumption that the secondary HVAC unit was turned off. The results were compared with existing energy usage data. It was determined that there were significant energy savings in the second scenario. It is expected that this study and its findings will help future research projects explore more ideas as alternatives to central HVAC, in improving the economic viability of existing options, and in developing a savings calculation tool that will help consumers make informed decisions on their best alternatives to central HVAC.

  • PDF

생애주기를 고려한 오피스 건물의 리모델링과 그린리모델링의 경제성 평가 연구 : 서울시 강남업무지구의 임대오피스 사례 (An Economic Evaluation Study of Office Remodeling and Green-remodeling Projects : A Simulation Approach to a Rental Office in GBD, Seoul)

  • 이성호;이재수
    • 대한건축학회논문집:계획계
    • /
    • 제34권3호
    • /
    • pp.23-34
    • /
    • 2018
  • Due to a waste of energy in korea, about 525,000 which are 75 percent of total buildings are at least 15 years old buildings that need remodeling. There are two current remodeling systems. One is a remodeling system to reduce a waste of resources from the reconstruction. The other is a green-remodeling system aimed to energy savings and reducing environmental costs. This study is to analyze quantitatively these current systems with respect to the cost-benefit caused by the life cycle and suggests the political and institutional implications through the interpretation of the results. For a quantitative analysis, we analyzed reducing maintenance costs and rent benefits with simulation by using opportunity costs, construction costs, plan costs and supervision costs as expense variables and using the reduced floor area ratio, institutional incentives, energy, water resources and certified emission reduction(CER) as benefit variables. As a result of the empirical study, the green-modeling was more beneficial in the field of environment such as the energy savings, however, the final benefits of remodeling which has no green building certification costs but more floor area ratio incentives were more economical. The green-remodeling system focused on reducing environmental costs and energy savings needs a equatable institutional incentive system.

Two Stage Hybrid Optimization을 사용한 ESS 최적 운전 전략에 대한 연구 (A Study on ESS Optimal Operation Strategy Using Two Stage Hybrid Optimization)

  • 공은경;손진만
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.833-839
    • /
    • 2018
  • This paper presents an analysis and the methodology of optimal operation strategy of the ESS(Energy Storage System) for reduce electricity charges. Electricity charges consist of a basic charge based on the contract capacity and energy charge according to the power usage. In order to use electrical energy at minimal charge, these two factors are required to be reduced at the same time. QP(Quadratic Programming) is appropriate for minimization of the basic charge and LP(Linear Programmin) is adequate to minimize the energy charge. However, the integer variable have to be introduced for modelling of different charge and discharge efficiency of ESS PCS(Power Conversion System), where MILP(Mixed Integer Linear Programming) can be used. In this case, the extent to which the peak load savings is accomplished should be assumed before the energy charge is minimized. So, to minimize the electricity charge exactly, optimization is sequentially performed in this paper, so-called the Two Stage Hybird optimization, where the extent to which the peak load savings is firstly accomplished through optimization of basic charge and then the optimization of energy charge is performed with different charge and discharge efficiency of ESS PCS. Finally, the proposed method is analyzed quantitatively with other optimization methods.

바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석 (Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies)

  • 이준우;박철수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF

Adaptive Cloud Offloading of Augmented Reality Applications on Smart Devices for Minimum Energy Consumption

  • Chung, Jong-Moon;Park, Yong-Suk;Park, Jong-Hong;Cho, HyoungJun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.3090-3102
    • /
    • 2015
  • The accuracy of an augmented reality (AR) application is highly dependent on the resolution of the object's image and the device's computational processing capability. Naturally, a mobile smart device equipped with a high-resolution camera becomes the best platform for portable AR services. AR applications require significant energy consumption and very fast response time, which are big burdens to the smart device. However, there are very few ways to overcome these burdens. Computation offloading via mobile cloud computing has the potential to provide energy savings and enhance the performance of applications executed on smart devices. Therefore, in this paper, adaptive mobile computation offloading of mobile AR applications is considered in order to determine optimal offloading points that satisfy the required quality of experience (QoE) while consuming minimum energy of the smart device. AR feature extraction based on SURF algorithm is partitioned into sub-stages in order to determine the optimal AR cloud computational offloading point based on conditions of the smart device, wireless and wired networks, and AR service cloud servers. Tradeoffs in energy savings and processing time are explored also taking network congestion and server load conditions into account.

에너지 소비효율 개선과 리바운드 효과: 수송부문을 중심으로

  • 김대욱;김종호
    • 자원ㆍ환경경제연구
    • /
    • 제21권2호
    • /
    • pp.321-340
    • /
    • 2012
  • 정부는 2009년도에 국내에서 판매된 전체 승용자동차의 평균연비가 $12.27km/{\ell}$로 전년($11.47km/{\ell}$) 대비 7.0% 향상되었다고 발표하였다. 이는 2009년의 평균연비 향상률은 평균에너지소비효율기준이 도입된 이후인 2006년~2008년간의 평균연비 향상률인 연평균 2.4%보다 약 3배 가까이 높은 수치이다. 정부는 또한 7%의 연비 향상으로 인해 연간 6만 toe의 에너지 소비절감(금액으로 환산시 335억 원) 및 16만톤의 $CO_2$ 배출량 저감효과가 있다고 주장하였다. 그러나, 이러한 주장은 리바운드 효과(rebound effect)를 간과하는 주장이다. 리바운드 효과에 따르면, 에너지 저감기술 진보는 에너지 사용량을 높여 에너지 절감의 긍정적 효과를 상쇄하는 경향이 있는 것으로 알려져 있다. 리바운드 효과가 실제로 존재하고 그 크기가 작지 않다면, 연비 향상에 따른 무역수지 개선 또는 환경오염절감의 효과는 실제보다 크지 않을 수 있다. 본 연구는 연비규제시에 발생 가능한 문제점의 존재 여부와 그 크기를 개별(disaggregate) 자료를 사용하여 계량경제학적으로 추정하였다. 분석 결과에 따르면 수송부문에서 리바운드 효과는 존재하고 그 크기가 0.299로 나타났다. 이러한 추정치는 정부에서 만약 이러한 반등 효과를 고려하지 않고 정책목표를 설정할 경우, 에너지 소비, 이산화탄소 배출 및 무역수지 등에서 정부에서 제시한 감축 목표치가 29.9% 미달될 수 있음을 의미한다.

  • PDF

An Energy Saving Scheme for Multilane-Based High-Speed Ethernet

  • Han, Kyeong-Eun;Yang, Choong-Reol;Kim, Kwangjoon;Kim, Sun-Me;Lee, Jonghyun
    • ETRI Journal
    • /
    • 제34권6호
    • /
    • pp.807-815
    • /
    • 2012
  • In this paper, we propose a scheme for partially dynamic lane control for energy saving in multilane-based high-speed Ethernet. In this scheme, among the given transmission lanes, at least one lane is always operating, and the remaining lanes are dynamically activated to alleviate the network performance in terms of queuing delay and packet loss in the range of acceptance. The number of active lanes is determined by the decision algorithm based on the information regarding traffic and queue status. The reconciliation sublayer adjusts the transmission lane with the updated number of lanes received from the algorithm, which guarantees no processing delay in the media access control layer, no overhead, and minimal delay of the exchanging control frames. The proposed scheme is simulated in terms of queuing delay, packet loss rate, lane changes, and energy saving using an OPNET simulator. Our results indicate that energy savings of around 55% (or, when the offered load is less than 0.25, a significant additional savings of up to 75%) can be obtained with a queuing delay of less than 1 ms, a packet loss of less than $10^{-4}$, and a control packet exchange time of less than $0.5{\mu}s$ in random traffic.

전문 ESCO 지정제 평가방안 연구 (A Study on the Evaluation Method for Professional ESCO)

  • 임기추
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.90-95
    • /
    • 2013
  • 기술 중심의 ESCO 전문화를 위한 전문 ESCO 지정제 평가기준 마련이 요청되어 왔다. 이에, 본 연구는 전문 ESCO 지정제도에 관한 평가기준을 설정하기 위해 5가지 목적을 전제하였다. 즉, 에너지 절감의 우수성, 경영지표의 건전성, 고객만족도, 원천기술 보유업체의 참여 유도, 절약성과 보증계약 중시 등이다. 이를 바탕으로 전문가 자문을 통해 전문 ESCO 지정을 위한 평가배점(안)을 전문성(40점), 경영상태(15점), 고객만족도(20점), 기술능력(25점) 등 평가지표로 구성하고, 각각 세부 평가항목의 선정 및 배점기준을 설정하였다. ESCO 업계 설문조사를 통해 비교적 높은 동의율을 보였다. 전문 ESCO 지정제도의 적용 시 기업규모를 중소기업으로 한정하고 적용기술 대상을 조명, 열병합발전, 공정개선, 폐열회수, 냉 난방설비 등 5개의 특정 기술분야로 지정하는 것이 가능할 것이다.