• 제목/요약/키워드: Energy Saving Strategy

검색결과 97건 처리시간 0.032초

에너지절약을 위한 열차운행전략에 관한 시뮬레이션 연구 (A Simulation Study on the Energy Saving Strategy of Train Operation)

  • 주영복;최규형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1594-1598
    • /
    • 2007
  • Energy saving is an important topic for each heavy user of the power system, including railway operators. Therefore, four strategy of train operations studied that maximum speed reduction, reduced acceleration rate, anticipatory coasting, and saw-tooth coasting for energy saving. The Simulation model of the study used to investigate the performance of a railway system, and it was used to study the effect of energy saving strategies for the train operation. The Study investigate train operation strategy for energy saving, investigate the effect of strategy, and find the energy optimization of acceleration, coasting, braking section used Run-Curve simulator from train data.

  • PDF

블라인드를 고려한 여름철 소규모 사무소 건물의 냉방 및 조명에너지 평가 (The Summer Cooling and Lighting Energy Performance Evaluation of Small Office Buildings with Venetian Blinds)

  • 정유근
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.39-45
    • /
    • 2013
  • The daylighting control system has to be applied to prevent the excessive incident daylight and reduce energy use. As the one of the most useful daylighting control systems, the blind system is simple and easy to install on the window for small office buildings. This study aims to evaluate the summer energy performance of small office buildings by venetian blinds and energy saving strategy of ministry of knowledge economy in korea. For the study, the simulations have been executed on blind installation conditions and lighting control methods. As results, the energy loads cut down 22 to 25(%) by using blind energy. Also, the efficient shows high on EMS system and low on $45^{\circ}$ slat angles. Also, using energy saving strategy can reduce about 13(%) energy load.

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

공작기계 주변장치의 에너지 절감 대기전략 (Standby Strategies for Energy Saving in Peripheral Equipment of Machine Tools)

  • 김태정;김태호;지성철
    • 한국정밀공학회지
    • /
    • 제30권5호
    • /
    • pp.486-492
    • /
    • 2013
  • Energy cost has been increasing rapidly to comply with environmental regulations worldwide and the manufacturing industry who consumes more than half of the total energy needs to improve their cost competitiveness considering environmental costs. Machine tools are essential elements in manufacturing industry and efforts have been made recently to increase their energy efficiency mainly by German and Japanese machine tool builders. In this paper, trends in energy saving technology are described on the hardware and software sides of peripheral equipment of machine tools. In addition, the power consumption of a machining center is measured and analyzed to develop a software-based standby strategy for energy saving with peripheral equipment of machine tools.

Energy-Saving Strategy for Green Cognitive Radio Networks with an LTE-Advanced Structure

  • Jin, Shunfu;Ma, Xiaotong;Yue, Wuyi
    • Journal of Communications and Networks
    • /
    • 제18권4호
    • /
    • pp.610-618
    • /
    • 2016
  • A green cognitive radio network (CRN), characterized by base stations (BSs) that conserve energy during sleep periods, is a promising candidate for realizing more efficient spectrum allocation. To improve the spectrum efficiency and achieve greener communication in wireless applications, we consider CRNs with an long term evolution advanced (LTE-A) structure and propose a novel energy-saving strategy. By establishing a type of preemptive priority queueing model with a single vacation, we capture the stochastic behavior of the proposed strategy. Using the method of matrix geometric solutions, we derive the performance measures in terms of the average latency of secondary user (SU) packets and the energy-saving degree of BSs. Furthermore, we provide numerical results to demonstrate the influence of the sleeping parameter on the system performance. Finally, we compare the Nash equilibrium behavior and social optimization behavior of the proposed strategy to present a pricing policy for SU packets.

저온송풍 공조시스템의 열원 제어 (Control Strategy for Cold Air Distribution System)

  • 정석권;김동규;금종수;박종일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.480-483
    • /
    • 2008
  • The cold-air distribution system is expected as an efficient method to reduce energy consumption in the air-conditioning system. We introduced some control strategies for the system by summarizing some references in the view point of energy saving. Direct digital control is specially emphasized as an important control technique for the system. Some drawbacks which habe been conventionally mentioned to apply the cold-air distribution to real fields can be solved by using the technique. The control strategy which is introduced in here will be available to build control system for the air-conditioning based on the cold-air distribution for energy saving.

  • PDF

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

Pulse Density Modulation Controlled Series Load Resonant Zero Current Soft Switching High Frequency Inverter for Induction-Heated Fixing Roller

  • Sugimura, Hisayuki;Kang, Ju-Sung;Saha, Bishwajit;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents the two lossless auxiliary inducors-assisted voltage source type half bridge(single ended push pull:SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation forwide its output power regulation ranges and load variations under constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operatprinciple is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation charactertics-based on the high frequency PDM strategy. The experimenoperating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimenones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliimplemented here is proved from the practical point of view.

  • PDF

Utility AC Frequency to High Frequency AC Power Frequency Converter without Electrolytic Capacitor Link for Consumer Induction Heating Appliances

  • Sugimura, H.;Eid, A.;Lee, H.W.;Kwon, S.K.;Suh, K.Y.;Nakaoka, M.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1364-1367
    • /
    • 2005
  • In this paper, a novel prototype topology of soft switching PWM controlled high frequency AC power conversion circuit without DC voltage smoothing chemical capacitor filter link from the voltage grid of utility frequency AC power supply source with 60Hz-100V or 60Hz-200V is proposed and introduced for innovative consumer induction heating(IH) boiler applications as hot water producer, steamer and super heated vapor steamer.

  • PDF

작업장치 위치에너지 회생을 위한 하이브리드 굴삭기 시스템 개발 (Development of Hybrid Excavator for Regeneration of Boom Potential Energy)

  • 윤종일;안경관;딩광졍;강종민;김재홍
    • 유공압시스템학회논문집
    • /
    • 제6권4호
    • /
    • pp.1-8
    • /
    • 2009
  • Nowadays with the high fuel prices, the demands for energy saving and green emission of construction machinery have highly been increased without sacrifice of working performance, safety and reliability. The aim of this paper is to propose a new energy saving hybrid excavator system using an electro-hydraulic actuator driven by an electric motor/generator for the regeneration of potential energy. A 5 ton class excavator is analyzed, developed with the boom for the evaluation of the designed system. The hardware implementation is also presented in this paper. A control strategy for the hybrid excavator is proposed to operate the machine with a highest efficiency. The energy saving ability of the proposed excavator is clearly verified through simulation and experimental results in comparison with a conventional hydraulic excavator.

  • PDF