• 제목/요약/키워드: Energy Save

검색결과 801건 처리시간 0.029초

배기열 회수용 종이 열교환기의 성능예측에 관한 연구 (A Study on the Performance Prediction of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 유성연;김진혁;정민호;지명석
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.372-380
    • /
    • 2008
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. Paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air. The purpose of this research is to obtain the experimental correlations for the friction factor, heat transfer coefficient, mass transfer coefficient and permeance of paper heat exchanger, which can be used to predict the performance of the paper heat exchanger. Pressure drops at various velocities, and sensible and latent heat transfer rates at various dry-bulb temperatures, relative humidities and specific humidities are measured to derive experimental correlations. The results of prediction using correlations show fairly good agreement with the experimental data obtained in the actual operating conditions.

무선센서네트워크에서 센서노드 에너지 절약을 위한 OC-MAC 기반의 전송횟수 감소 기법 (OC-MAC with Reducing the Number of Transmission to save energy in Wireless Sensor Networks)

  • 황보람;;손민한;추현승
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2012년도 춘계학술발표대회
    • /
    • pp.602-604
    • /
    • 2012
  • 무선센서네트워크에서 센서노드가 에너지를 적게 사용하여 네트워크 시간을 연장하는 것은 중요한 이슈이다. 센서노드의 에너지 소비를 줄이기 위해 듀티사이클이 제안되었고 낮은 비동기식 듀티사이클에서 각 센서노드는 독립적으로 활성화되며 트래픽이 적은 경우에 에너지를 효율적으로 줄인다. 하지만 전송할 데이터가 증가하면 낮은 듀티사이클로 인해 송신노드는 수신노드의 활성화시간까지 많은 시간을 기다려야 한다. 이때 사용하는 에너지는 데이터 전송에 사용되는 에너지보다 크다는 문제점이 있다. 이를 해결하기 위해 전송노드는 자신보다 잔여 에너지가 큰 이웃노드에게 데이터를 전송하고 비활성상태로 전환되고 데이터를 모아 전송하는 OC-MAC 기법이 제안되었다. 하지만 OC-MAC 기법은 데이터를 위임할 이웃노드 선택시 자신보다 잔여 에너지가 큰 노드들 중 잔여 에너지가 제일 적은 노드를 선택한다. 이에 따라 센서노드들이 에너지를 균형있게 사용하지 못하는 문제점이 발생한다. 따라서 본 논문이 제안하는 기법은 이웃노드 중 잔여 에너지가 큰 이웃노드에게 데이터를 전송함으로 센서노드의 에너지를 균형 있게 사용하고 무센서네트워크 수명을 연장한다.

Current Limiting and Interrupting Operation of Hybrid Self-Excited Type Superconducting DCCB

  • Choi, S.J.;Lim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.55-59
    • /
    • 2018
  • Currently, the development of industry makes needs larger electric supply. Providers must consider the efficiency about losses and reliability of the system. In this case, DC power system can save electrical energy; long-distance transmission line losses. Relevance to switch technology with a voltage-source converter (VSC) in AC-DC conversion system have been researched. But, protection device of DC-link against fault current is still needed to study much. VSC DC power system is vulnerable to DC-cable short-circuit and ground faults, because DC-link has a huge size of capacitor filter which releases extremely large current during DC faults. Furthermore, DC has a fatal flaw that current zero crossing is nonexistence. To interrupt the DC, several methods which make a zero crossing is used; parallel connecting self-excited series LC circuit with main switch, LC circuit with power electronic device called hybrid DC circuit breaker. Meanwhile, self-excited oscillator needs a huge size capacitor that produces big oscillation current which makes zero crossing. This capacitor has a quite effective on the price of DCCB. In this paper, hybrid self-excited type superconducting DCCB which are using AC circuit breaker system is studied by simulation tool PSCAD/EMTDC.

Power Saving Scheme by Distinguishing Traffic Patterns for Event-Driven IoT Applications

  • Luan, Shenji;Bao, Jianrong;Liu, Chao;Li, Jie;Zhu, Deqing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권3호
    • /
    • pp.1123-1140
    • /
    • 2019
  • Many Internet of Things (IoT) applications involving bursty traffic have emerged recently with event detection. A power management scheme qualified for uplink bursty traffic (PM-UBT) is proposed by distinguishing between bursty and general uplink traffic patterns in the IEEE 802.11 standard to balance energy consumption and uplink latency, especially for stations with limited power and constrained buffer size. The proposed PM-UBT allows a station to transmit an uplink bursty frame immediately regardless of the state. Only when the sleep timer expires can the station send uplink general traffic and receive all downlink frames from the access point. The optimization problem (OP) for PM-UBT is power consumption minimization under a constrained buffer size at the station. This OP can be solved effectively by the bisection method, which demonstrates a performance similar to that of exhaustive search but with less computational complexity. Simulation results show that when the frame arrival rate in a station is between 5 and 100 frame/second, PM-UBT can save approximately 5 mW to 30 mW of power compared with an existing power management scheme. Therefore, the proposed power management strategy can be used efficiently for delay-intolerant uplink traffic in event-driven IoT applications, such as health status monitoring and environmental surveillance.

국내 표준계사의 냉난방부하 특성 연구 (A Study on the Characteristics of Heating and Cooling Loads of Standard Chicken Houses in South Korea)

  • 권영철
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.235-243
    • /
    • 2019
  • In South Korea, millions of poultry have died due to repeated heat waves every year. The purpose of this study is to analyze the characteristics of heating and cooling loads of chicken houses in Korea and to present an effective insulation and ventilation measures to minimize the damage of poultry due to summer heat wave and to save energy in chicken houses in winter. The heating and cooling loads of standard chicken house were calculated. As a result of the calculation of maximum heating load based on the minimum ventilation rate in winter, the outdoor air temperature requiring heating was $6{\sim}7^{\circ}C$ to keep the indoor air temperature of chicken houses as $24^{\circ}C$. The peak cooling load of chicken houses was mostly taken by the heat generated by chickens and the heat gain due to ventilation. The heat gain through building envelopes was as small as neglectable. Most of chicken houses is usually cooled by gigantic forced ventilation in summer in Korea. When the chicken houses are cooled by electric cooling machine such as cooler or air conditioner, it is more effective to keep minimum ventilation rate to reduce the maximum cooling load. To lower the temperature of supplying water to cooling pad, it is recommended to use the underground water below 10 meters from the ground if there is abundant underground water.

Effect of graphene oxide on polyvinyl alcohol membrane for textile wastewater treatment

  • Zahoor, Awan;Naqvi, Asad A.;Butt, Faaz A.;Zaidi, Ghazanfar R.;Younus, Muhammad
    • Membrane and Water Treatment
    • /
    • 제13권3호
    • /
    • pp.121-128
    • /
    • 2022
  • A tremendous amount of energy resources is being wasted in cleaning wastewater to save the environment across the globe. Several different procedures are commercially available to process wastewater. In this work, membrane filtration technique is used to treat the textile wastewater because of its cost effectiveness and low environmental impacts. Mixed Matrix Membrane (MMM) consist of Polyvinyl Alcohol (PVA) in which Graphene Oxide (GO) was added as a filler material. Five different membranes by varying the quantity of GO were prepared. The prepared membrane has been characterized by Scanning Electron Microscopy (SEM), X-Ray Diffractometry (XRD), Fourier Transformed Infrared Spectroscopy (FTIR) and Water Contact Angle (WCA). The prepared membranes have been utilized to treat textile wastewater. The synthesized membranes are used for the elimination of total dissolve solids (TDS), total suspended solids (TSS), Methylene blue (MB) dye and copper metallic ions from textile wastewater. It is concluded that amount of GO has direct correlation with the quality of wastewater treatment. The maximum removal of TDS, TSS, MB and copper ions are found to be 7.42, 23.73, 50.53 and 64.5% respectively and are achieved by 0.02 wt% PVA-GO membrane.

항온챔버에서 히트펌프 실외기의 성능을 평가하는 실제 운전 (Actual operation characteristics to evaluate the performance of heat pump outdoor unit in the constant temperature chamber)

  • 김종열
    • 융합신호처리학회논문지
    • /
    • 제23권3호
    • /
    • pp.123-128
    • /
    • 2022
  • 에너지를 절약하기 위해 고효율 히트펌프를 개발하기 위한 많은 연구가 이루어지고 있으며, 실외기 코일에 발생하는 서리가 발생하는 현상을 줄이거나 없애기 위한 연구도 동시에 이루어지고 있다. 계절과 관계없이 히트펌프의 실외기에 서리가 발생하지 않는 연구를 진행할 수 있도록 자연 상태와 동일한 조건에서 실험할 수 있는 항온챔버를 구축하였다. 항온챔버 내에 설치된 히트펌프의 실외기에 자연 상태와 같은 환경을 제공하여 실험하였으며, 그 결과 외기온도가 낮을수록 히트펌프의 효율은 낮으며, 히트펌프 시스템의 운전이 안정화 상태에 도달하는 시간은 외기온도가 낮을수록 길어지는 것을 확인하였다.

압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

항온챔버에서 히트펌프 실외기의 성능 평가를 위한 시뮬레이션 (Simulation for Performance Evaluation of Heat Pump Outdoor Unit in the Constant Temperature Chamber)

  • 김종열
    • 융합신호처리학회논문지
    • /
    • 제24권3호
    • /
    • pp.140-146
    • /
    • 2023
  • 에너지를 절약하기 위해 고효율 히트펌프를 개발하기 위한 많은 연구가 이루어지고 있다. 그 중, 실외기 코일에 발생하는 서리가 발생하는 현상을 줄이거나 없애기 위한 연구도 동시에 이루어지고 있다. 계절과 관계없이 히트펌프의 실외기에 서리가 발생하지 않는 연구를 진행할 수 있도록 자연 상태와 동일한 조건에서 실험할 수 있는 항온챔버를 구축하였다. 항온챔버 내에 설치된 히트펌프의 실외기에 자연 상태와 같은 조건으로 시뮬레이션하였으며, 그 결과 외기온도가 낮을수록 냉매의 질량유량은 감소하였으며, 냉매의 건도 역시 외기온도에 따라 선형적으로 증가함을 확인하였다.

무선 센서 네트워크에서 에너지 효율성 향상을 위해 공격정보를 활용한 동적 여과 기법의 키 재분배 기법 (Key Re-distribution Scheme of Dynamic Filtering Utilizing Attack Information for Improving Energy Efficiency in WSNs)

  • 박동진;조대호
    • 한국지능시스템학회논문지
    • /
    • 제26권2호
    • /
    • pp.113-119
    • /
    • 2016
  • 무선 센서 네트워크는 제한된 자원과 무선 통신 사용으로 공격자에게 취약하기 때문에 공격자는 쉽게 노드를 훼손할 수 있고 허위 보고서 주입 공격과 같은 다양한 공격을 시도한다. 허위 보고서 주입 공격은 허위 보고서를 전달하는 과정에서 발생하는 에너지 고갈과 기지 노드에 허위 알람을 일으켜 금전적 손실을 발생시킨다. 이 문제를 다루기 위한 기존 기법 중 하나인 동적 여과 기법은 허위 보고서를 탐지함으로써 에너지를 절약할 수 있다. 동적 여과 기법의 키 분배 단계는 공격이 발생한 소스 노드 근처의 노드가 허위 보고서를 탐지할 수 있는 키를 갖지 못할 수 있다. 따라서 지속적인 공격에 노출될 경우 불필요한 에너지 손실이 발생한다. 본 논문에서는 이러한 문제를 개선하기 위해 키 재분배 기법을 제안한다. 제안 기법은 초기에 분배된 비밀 키를 사용하여 빠른 허위 보고서 탐지를 통해 에너지를 절약한다. 실험 결과는 기존 기법과 비교하였을 때 최대 26.63% 에너지 절약과 최대 15.92%의 탐지 성능 향상을 보인다.