Nie, H.T.;Wan, Y.J.;You, J.H.;Wang, Z.Y.;Lan, S.;Fan, Y.X.;Wang, F.
Asian-Australasian Journal of Animal Sciences
/
v.28
no.8
/
pp.1140-1149
/
2015
This research aimed to define the energy requirement of Dorper and Hu Hybrid $F_1$ ewes 20 to 50 kg of body weight, furthermore to study energy requirement changes with age and evaluate the effect of age on energy requirement parameters. In comparative slaughter trial, thirty animals were divided into three dry matter intake treatments (ad libitum, n = 18; low restricted, n = 6; high restricted, n = 6), and were all slaughtered as baseline, intermediate, and final slaughter groups, to calculate body chemical components and energy retained. In digestibility trial, twelve ewes were housed in individual metabolic cages and randomly assigned to three feeding treatments in accordance with the design of a comparative slaughter trial, to evaluate dietary energetic values at different feed intake levels. The combined data indicated that, with increasing age, the net energy requirement for maintenance ($NE_m$) decreased from $260.62{\pm}13.21$ to $250.61{\pm}11.79kJ/kg^{0.75}$ of shrunk body weight (SBW)/d, and metabolizable energy requirement for maintenance (MEm) decreased from $401.99{\pm}20.31$ to $371.23{\pm}17.47kJ/kg^{0.75}$ of SBW/d. Partial efficiency of ME utilization for maintenance ($k_m$, 0.65 vs 0.68) and growth ($k_g$, 0.42 vs 0.41) did not differ (p>0.05) due to age; At the similar condition of average daily gain, net energy requirements for growth ($NE_g$) and metabolizable energy requirements for growth ($ME_g$) for ewes during late fattening period were 23% and 25% greater than corresponding values of ewes during early fattening period. In conclusion, the effect of age upon energy requirement parameters in the present study were similar in tendency with previous recommendations, values of energy requirement for growth ($NE_g$ and $ME_g$) for Dorper and Hu crossbred female lambs ranged between the NRC (2007) recommendation for early and later maturating growing sheep.
Proceedings of the Korean Institute of Building Construction Conference
/
2011.05a
/
pp.205-206
/
2011
Various studies on energy saving for construction sites have been carried out and some construction machines using motors have installed regenerative systems such as elevators and excavators. The construction lift also uses motors and generates more regenerative energy when the lifts descend because lifts convey many construction materials and workers. For this reason, it is possible to apply the regenerative system to the construction lift. However, if the system is applied without considering the lift's characteristics, the new development would fail; we therefore need to propose a performance requirement. Thus, the purpose of this study is to propose a performance requirement for the energy-regenerative lift prior to developing the energy-regenerative lift.
Energy obtained by grazing cattle in oil palm plantations is usually used for maintenance of body functions, the construction of body tissues and pregnancy, the synthesis of milk and the conversion to mechanical energy used for activities such as walking, eating and others. In this study, attempt was made to estimate metabolizable energy (ME) requirement of grazing cattle. Models of ME requirement (MER) for maintenance, gain, pregnancy, lactation and activities were developed. ME system and units were used because of wide recognition. Estimation of ME intake in grazing cattle was expressed as MEVI = $14.58{\times}VI{\times}DMD$, and under grazing condition MEVI = $MER_i$. MER was expressed as a function of net energy(NER, MJ) required for the i'th body function. Coefficient of efficiency for conversion of ME into net energy(ki) was adopted from literatures. Quantifying of ME requirement for Kedah-Kelantan cattle under grazing condition was made by using equation MERM = NEM / kn. The estimated values of MER for Kedah-Kelantan cattle is quite reasonable if compared with other estimates as reported in literatures from stall-fed animals. Dynamic MER models for grazing herd was developed in order to estimate ME requirement for maintenance and productions. These ME requirement models can be used for prediction of energy utilization pattern of the herd in the grazing systems.
A study was conducted to investigate nitrogen balance and to estimate daily nitrogen requirement in 43 Korean female college students students maintaining their usual diet and activity levels. Nitrogen intake and excretion were measured in two separate peroids about one month apart, each period lasting for 3 days. Nitrogen intake was assessed by duplicate portion analysis of diet, and N excretion in faces and urine were measured during the study period. Mean daily nitrogen intake level was 129.3mg/kg B.W and the apparent digestibility of nitrogen was 76%. Mean daily urinary nitrogen excretion was 113.5mg/kg BW. 895 of total nitrogen intake. Mean daily nitrogen balance of subjects was -14.5mg/kg BW. Mean daily requirements of nitrogen for 0 balance, calculated by regression analysis of N balance and energy-adjusted N intake. were 1) 197.mg/kg B.W with the present energy intake level of the study subjects. 2) 157mg/kg B.W when energy intake is sufficient to maintain energy balance, and 30 130mg/kg B.W. when energy intake is Korean RDA level for moderate activity. When energy intake level is sufficient to meet their requirement, daily protein requirement for 0 balance is about 1.0g/kg B.W. The results of this study indicate that nitrogen intake level of young female college students is not sufficient to meet their requirements, and they should increase protein intake together with increase in energy intake.
Journal of the Korean Institute of Rural Architecture
/
v.20
no.4
/
pp.1-8
/
2018
In this study, we survey the 2 buildings at the Central 1 and 8 buildings at the Central 2, which are divided by each climate region in the rural regions. Major heat loss factors are 47% loss of the outer shell including outer wall, roof, and bottom, 30% loss through window, and 23% loss through crevice wind. We analyze the energy simulation of ECO2 program to construct a zero energy building regarding village hall located in Jung Juk 4-le at Centeral 2. We simulate the primary energy requirement regarding village hall and the simulated results show the $265.3kWh/m^2{\cdot}a$ and it may estimate '2' energy efficiency grade. The energy requirement regarding village hall is the $183.2kWh/m^2{\cdot}a$ when the passive technology are applied in village hall. We research total amount of energy requirement in village hall when the passive and active technologies such as solar cell with 3kW and solar thermal with $20m^2$, geothermal power with 17.5kW. The simulated results show the improved energy efficiency certification grade with $1^{{+}{+}{+}}$ due to the reduced primary energy requirement with 73% when passive technology including 3kW of solar panel is applied and the energy independence rate is 54%, which is estimated to be 4th grade of zero energy buildings. The order of energy consumption are solar panel, solar thermal, and geothermal power under applied passive technology in the building. In order to expand the zero energy building, it is necessary to introduce the zero energy evaluation system in the rural region.
Energy requirement of Rhode Island Red (RIR) hens was studied by comparative slaughter technique. Seventeen hens above 72 weeks of age were slaughtered in batches. Batch I consisted of 5 hens which were slaughtered initially. Batch II comprised of six hens, which were fed ad libitum broken rice (BR)-based diet for 18 days. Record of feed intake, number of eggs laid and egg weight during the period was kept. These hens were slaughtered and body energy content was determined. Egg energy was consisted as energy deposited. Batch III consisting of six hens which were fed varying quantity of diet for 15 days, were slaughtered similarly as hens of batch II. Regression equation (body weight to body energy) developed on batch I was applied to batch II and developed on batch II was applied to batch III hens, to find out initial body energy content of hens. Egg energy (EE) was calculated according to formula: EE (kcal) = -19.7 + 1.81 egg weight (g). Regressing metabolisable energy (ME) intake on energy balance (body energy change + egg energy), maintenance ME requirement of hens was found to be $119.8kcal/kg\;W^{0.75}/d$. Multiple regression of ME required for production on energy retained as protein and fat (body plus egg energy) indicated that RIR hens synthesize proteins with an efficiency of 85.5 and fat with an efficiency exceeding 100 percent on BR based diet.
Two experiments were conducted with one-day-old straight run Muscovy ducklings to determine their protein and energy requirements. In the 1st experiment, isoenergetic diets (2800 kcal ME/kg) with three dietary proteins, 18, 20 and 22% in the starter period (1-28 days) and 16, 18 and 20% in the grower and finisher period (29-84 days) were used to determine the optimum protein requirement. While, in the 2nd experiment, isonitrogenous diets (20%, C.P.) with three dietary energy, 2700, 2800 and 2900 kcal ME/kg in the starter period (1-28 days) and (18% C.P.) with 2800, 2900 and 3000 kcal ME/kg in the grower-finisher period (29-84 days) were used to determine the optimum energy requirement. It was observed that 20% C.P. in the starter period and 18% C.P. in the grower and finisher period was adequate for optimum performance, while, 2900 kal ME/kg was sufficient to meet the optimum energy requirement in both the starter, grower-finisher period as regards body weight, feed efficiency, protein efficiency and caloric efficiency are concerned.
balance and to estimate daily energy requirement in 43 Korean female college students maintaining their usual diet and activity level. Energy intake and expenditure were measured in two separate periods about one month apart, each period lasting for 3 days. All the subjects participated in both periods. Energy intake was assessed by two methods ; weighed diet record and duplicate portion analysis of diet minus fecal and urinary excretion. Mean daily energy intake level calculated from diet records was 28.5 kcal/kgB.W(1, 476 kcal/day), and similar to the level of 27.8 kcal/kgB.W(1, 438 kcal/days) obtained from the chemical analysis of duplicate portions. Mean daily energy expenditure, calculated from activity records of each subject, was 34.6 kcal/kgB.W, or 1.39 times BMR, which corresponds to light activity level. Mean daily energy balance of subjects was -5.9 kcal/kgB.W. Mean daily requirement of energy, calculated from the activity records of the subjects, was 34.6 kcal/kgB.W, similar to the level of the Korean RDA for light activity level. The results of this study indicate that 1) the activity level of the study subjects corresponds to the sedentary level ; 2) present Korean RDA for energy for light activity is adequate for the subjects ; and 3) the subjects should increase their energy intake since they are largely in negative energy balance.
Proceedings of the Korean Nuclear Society Conference
/
1996.05b
/
pp.505-510
/
1996
A simple model for RAM (Reliability, Availability and Maintainability) analysis and its computer code are developed for application to DUPIC fuel fabrication system. The approach is obtained by linking the allocation model (top-down method) to bottom-up method for RAM analysis. As a result, the availability requirement of subsystem, as well as the buffer storage requirement between processes, are evaluated for the DUPIC facility..
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.