수소기반 신재생에너지 복합발전 시스템의 지역별 운영성과 분석 - HOMER를 활용한 사례 연구 (Performance Analysis of Hydrogen Based Hybrid System Using HOMER - a Case Study in South Korea)

  • 이명원;손민희;김경남
    • 한국수소및신에너지학회논문집
    • /
    • 제29권6호
    • /
    • pp.606-619
    • /
    • 2018
  • This study focuses on the performance of hydrogen energy based hybrid system in terms of system reliability of electricity generation. With this aim to evaluate the off-grid system of photovoltaic (PV), wind turbine, electrolyzer, fuelcell, $H_2$ tank and storage batteries, 14 different sites in South Korea are simulated using HOMER. Performance analysis includes simulation on the different sites, verification of operational behaviors on regional and seasonal basis, and comparison among a control group. The result shows that the generation performance of hydrogen powered fuelcell is greatly affected by geographical change rather than seasonal effect. In addition, as the latitude of the hybrid systems location decrease, renewable power output and penetration ratio (%) increase under constant electrical load. Therefore, the hydrogen based hybrid system creates the stability of electricity generation, which best suits in the southern part of South Korea.

유니몰프 압전소자를 이용한 발전 판넬의 출력특성에 관한 연구 (A Study of Output Characteristics for the Generation Panel using Unimorph Piezoelectric Element)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권3호
    • /
    • pp.250-259
    • /
    • 2010
  • The ability for energy harvesting via the piezoelectric effect was studied for a unimorph element such as piezo buzzer. A simple equivalent circuit was proposed to predict the energy generated based on the internal stress. Unimorphs with a metal-cavity were used as a driving device of the generation panel. Both the AC open voltage and DC output voltage as a function of pressure period and number of element were measured. For the unimorph generation circuit, DC output voltage varies with pressure period, reaching a maximum value at $470{\mu}F$. The maximum output voltage a according to load resistance was measured at $1M{\Omega}$. Data analysis of the DC output voltage and time constant indicated that number of piezoelectric element of optimum was 60~80. It was found that piezoelectric unimorph has the possibility to be used as the driving element of the electric generation.

빌딩 마이크로그리드가 포함된 새로운 빌딩에너지 시스템 구축방향에 관한 연구 (The Novel Configuration for Building Energy System Including Build ins Microgrid)

  • 홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2008
  • The recent development of efficient thermal prime movers for distributed generation id changing the focus of the production of electricity from large centralized power plants to local generation units scattered over the territory. The scientific communality is addressing the analysis and planning of the distributed energy resources(der) with wide spread approaches, taking into account technical, environmental, economical and social issues. The coupling of cogeneration system to absorption/electric chillers or heat pumps as well as the interactions with renewable sources, allow for setting up multi-generation systems for building cooling heating and power(BCHP) systems of different energy vectors such as electricity, heat(at different enthalpy levels), cooling power, hydrogen, various chemical substances and so forth. Adoption of the composite multi-generation systems may lead to significant benefits in term of higher efficiency, reduced $CO_2$ emissions and enhanced economy. This paper outlines the main aspects of the BCHP system framework, illistrating its characteristics and summarizing the relevant distributed multi-generation structures.

  • PDF

미세먼지와 기상정보 기반의 AHP 분석을 통하여 태양광 발전소 최적입지선정에 대한 사례연구 (A Case Study for Analyzing the Optimal Location for A Solar Power Plant via AHP Analysis with Fine Dust and Weather Information)

  • 이건주;이기현;강성우
    • 대한안전경영과학회지
    • /
    • 제19권4호
    • /
    • pp.157-167
    • /
    • 2017
  • Solar energy has been known as a successful alternative energy source, however it requires a large area to build power generation facilities compared to other energy sources such as nuclear power. Weather factors such as rainy weather or night time impact on solar power generation because of lack of insolation and sunshine. In addition, solar power generation is vulnerable to external elements such as changes in temperature and fine dust. There are four seasons in the Republic of Korea hereby variations of temperature, insolation and sunshine are broad. Currently factors that cause find dust are continuously flowing in to Korea from abroad. In order to build a solar power plant, a large area is required for a limited domestic land hereby selecting the optimal location for the plant that maximizes the efficiency of power generation is necessary. Therefore, this research analyze the optimal site for solar power generation plant by implementing analytic hierarchy process based on weather factors such as fine dust. In order to extract weather factors that impact on solar power generation, this work conducts a case study which includes a correlation analysis between weather information and power generation.

하수처리시설의 에너지 자립화 방안 연구 (Study on Energy Independence Plan for Sewage Treatment Plant)

  • 김영준;정철권;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.15-20
    • /
    • 2008
  • The objectives of this study are to analyze the energy independence plan and to propose a suitable sewage treatment plant in Korea. The total amount of electricity consumption for public sewage treatment plant was estimated as 1,182 GWh in 2007. It was estimated that total 16 sewage treatment plants with renewable energy systems produced electricity of 15.2 GWh per year, which could replaced 0.8% of total electricity used for sewage treatment. It was found that domestic sewage treatment plants with power generation plants by digestion gas were installed in 7 places and produced electricity of 13 GWh per year. It was also found that the power generation plants by digestion gas were the most cost-effective for sewage treatment out of the renewable energy systems based on the benefit-cost analysis.

  • PDF

탄소의 사회적 비용에 따른 수상 태양광 사업의 경제성 변화 (Changes in the Economic Feasibility of a Floating Photovoltaics Project due to the Social Cost of Carbon)

  • 임재준;김진수
    • 신재생에너지
    • /
    • 제20권1호
    • /
    • pp.26-37
    • /
    • 2024
  • Renewable energy sources play a key role in achieving carbon neutrality and zero net emissions in the power generation sector. Various efforts have been made to support the deployment of renewable energy, particularly solar photovoltaic and wind power, including policies to internalize the external cost of carbon emissions. In this study, we conducted a financial analysis of a 800 MW floating photovoltaic system and compared it with ground solar power generation. Additionally, we conducted a cost-benefit analysis that included the social cost of carbon. The findings showed that the floating photovoltaic project can meet the profitability target through an appropriately designed internalization of the social cost of carbon.

RDF발전에 의한 열효율향상 및 $CO_2$삭감효과에 대한 평가 (An Evaluation on the Effect of the MSW-RDF Power Generation on the Thermal Efficiency and $CO_2$ Reduction)

  • 최갑석;최연석;김석준;권영배
    • 연구논문집
    • /
    • 통권31호
    • /
    • pp.45-51
    • /
    • 2001
  • One of emerging technologies under development in the advanced countries is considered as RDF(Refuse Derived Fuel) power generation, which could meet both the requirement of an alternative energy resource utilization and $CO_2$ reduction. This paper deals with the effect to the thermal effiency and CO2 reduction of RDF firing power generation. The statistical data of domestic MSW generation in last year in small and medium cities for evaluating the merits of the RDF power generation were used. The analysis for RDF power generation compared to the existing incinerator w/o(or w/) power generation shows around 20.6%(10.0%) up in the total thermal efficiency and 57.0%(31.4%) up in the $CO_2$ reduction respectively.

  • PDF

구성 재료와 방사조도 특성에 따른 태양전지모듈의 최대출력 분석 (Analysis of Maximum Power Generation of Photovoltaic Module Depending on Constituent Materials and Incident Light Characteristics)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.1-6
    • /
    • 2007
  • In this study, we analyze the maximum power generation of photovoltaic(PV) module depending on constituent materials and incidence angle dependence of light. To verify characteristics of constituent materials, we made photovoltaic modules with 4 kinds of solar cells and textured glass according to fabrication method. To find the degree of the maximum power generation dependence on intensity of light, Solar Simulator is applied by changing angle of module and light intensity. Through this experiment, to obtain maximum power generation from limited PV modules, it is needed to fully understand constituent materials, fabrication method and dependence of incident light characteristics.

Topology Generation and Analysis of the No Dead Time AC/DC Converter

  • Zheng, Xinxin;Xiao, Lan;Tian, Yangtian
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.249-256
    • /
    • 2014
  • A novel topology generation method for the no dead-time three-phase AC/DC converter is proposed in this study. With this method, a series of no dead time topologies are generated and their operation principles are analyzed. The classic three-phase bridge AC/DC converter can realize a bidirectional operation. However, dead-time should be inserted in the driving signals to avoid the shoot-through problem, which would cause additional harmonics. Compared with the bridge topology, the proposed topologies lack the shoot-through problem. Thus, dead time can be avoided. All of the no dead time three-phase AC/DC converters can realize bidirectional operation. The operating principles of the converters are analyzed in detail, and the corresponding control strategies are discussed. Comparisons of waveform distortion and efficiency among the converters are provided. Finally, 9 KW DSP-based principle prototypes are established and tested. Simulation and experimental results verify the theoretical analysis.

태양광 모듈 출력 보상을 위한 마이크로컨버터 시제품 동작 특성 분석 (Characteristics Analysis of Proto-type Microconverter for Power Output Compensation of Photovoltaic Modules)

  • 김지현;김주희;이정준;박종성;김창헌
    • Current Photovoltaic Research
    • /
    • 제10권4호
    • /
    • pp.133-137
    • /
    • 2022
  • The economic feasibility of a photovoltaic (PV) system is greatly influenced by the initial investment cost for system installation. Also, electricity generation by PV system is highly important. The profits competitiveness of PV system will be maximized through intelligent operation and maintenance (O&M). Here, we developed a microconverter which can maximize electricity generation from PV modules by tracking the maximum power point of PV modules, and help efficient O&M. Also, the microconverter mitigates current mismatch caused by shading, hence maximize power generation. The microconverters were installed PV modules and demonstrated through the field tests. Power outputs such as voltage, string current were measured with variuos weather environments and partial shadings. We found that PV modules with the microconvertors shows 12.05% higher power generation compared to the reference PV modules.