• 제목/요약/키워드: Energy Equation

검색결과 2,842건 처리시간 0.031초

균열을 내재한 회전체의 에너지방출률 (The Energy Release Rate for Cracks in a Rotating Continuum)

  • 이태원
    • 대한기계학회논문집
    • /
    • 제19권2호
    • /
    • pp.330-337
    • /
    • 1995
  • For a rotating body with cracks, the new energy release rate equation is presented. The derived equation is different from the other researcher's results. It is a path-independent integral which excluded the derivatives of displacements near the crack tip, thereby improving the numerical accuracy of the energy release rate computation. Moreover, as the equation was derived on basis of the energy principle and non-linear elasticity without assumptions, it can applied to the cracked body with arbitrary shape under elastic-plastic deformation. Several examples are treated to demonstrate the efficiency and accuracy of the proposed method compared to existing methods.

공급압력 변화에 의한 공기압 실린더 구동장치의 소비에너지 변화량 추정 방법 (A Method of Estimation of Energy Consumption according to a Supply Pressure for Pneumatic Cylinder Driving Apparatus)

  • 장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권2호
    • /
    • pp.15-20
    • /
    • 2012
  • Pneumatic cylinder meter-out driving apparatus is used widely because it is clean, lightweight, and can be easily serviced. In this study an estimation method of energy consumption for pneumatic cylinder meter-out driving apparatus is proposed. The proposed method is derived from state equation and energy equation of air, and, the equation of motion of a moving part of a pneumatic cylinder reflecting the characteristics of the meter-out driving. The effectiveness of the proposed method is proved by simulation study and it demonstrates that the proposed method can evaluate the energy consumption quickly and easily when the parameters of the driving apparatus are changed.

Hybrid 적분방정식을 사용한 Flap-Harbour 복합체 파 에너지 흡수효율 추정 (Prediction of Wave Energy Absorption Efficiency of a Flp-Harbour Device by a Hybrid Integral Equation)

  • 김현주
    • 한국해양공학회지
    • /
    • 제14권2호
    • /
    • pp.1-6
    • /
    • 2000
  • Wave energy absorption by a flap equipped with a harbor in a water of finite depth is studied. The wave potential is calculated by a hybrid integral equation consisting of Green integral equations associated with Rankine and Kelvin Green functions. The absorbed wave energy is calculated by both the near-field and far-field methods. The present methods can be used for the design of a flap-harbor wave energy absorber since the numerical results by the two methods are in good agreement.

  • PDF

A continuous solution of the heat equation based on a fuzzy system

  • Moon, Byung-Soo;Hwang, In-Koo;Kwon, Kee-Choon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권1호
    • /
    • pp.13-17
    • /
    • 2003
  • A continuous solution of the Dirichlet boundary value problem for the heat equation $u_t$$a2u_{xx}$ using a fuzzy system is described. We first apply the Crank-Nicolson method to obtain a discrete solution at the grid points for the heat equation. Then we find a continuous function to represent approximately the discrete values at the grid points in the form of a bicubic spline function (equation omitted) that can in turn be represented exactly by a fuzzy system. We show that the computed values at non-grid points using the bicubic spline function is much smaller than the ones obtained by linear interpolations of the values at the grid points. We also show that the fuzzy rule table in the fuzzy system representation of the bicubic spline function can be viewed as a gray scale image. Hence, the fuzzy rules provide a visual representation of the functions of two variables where the contours of different levels for the function are shown in different gray scale levels

비압축성 유동 해석을 위한 압축성 유동 해석자 확장 (Extension of Compressible Flow Solver to Incompressible Flow Analysis)

  • 김동욱;김민수;이승수
    • 한국항공우주학회지
    • /
    • 제49권6호
    • /
    • pp.449-456
    • /
    • 2021
  • 본 연구에서는 저마하수 예조건화 기법이 적용된 기존 압축성 해석자의 해석 범위를 최소한의 수정으로 비압축성 유동해석이 가능하도록 확장하는 전략을 제시하였다. 이를 위해 압축성 총 에너지 방정식과 동일한 형태의 에너지 방정식을 사용하였다. 이러한 에너지 방정식은 비압축성 지배방정식인 연속방정식, 열에너지 방정식과 역학적 에너지방정식의 선형 조합을 통해 얻어진다. 이렇듯 압축성 방정식과 동일한 형태를 갖는 비압축성 지배방정식에 시간 전진 기법을 적용하기 위해 Turkel의 가상 압축성 기법을 적용하였다. 또한 Roe 평균이 공통의 압축성/비압축성 지배방정식에서 모두 유효함을 보였다. 압축성 해석자에 위 내용을 적용하여 비압축성 해석이 가능하도록 확장하는 과정은 본래의 압축성 해석자를 이용한 압축성 해석에 아무런 영향이 없다. 확장된 해석자를 통한 비압축성 해석 검증을 위해 비점성, 층류 그리고 난류 유동에 대한 순차적 해석을 수행하였다.

Sea surface temperature estimation from remote measurement of the thermal radiation

  • Mima, Kazuhiko;Satoh, Makoto;Moriyama, Masao;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.12-15
    • /
    • 1994
  • To establish the sea surface temperature estimation scheme for the upcoming advanced remote sensor, the quasi-analytical solution of the approximated radiative transfer equation which express the radiative transfer process of the radiant energy radiated from the sea surface to the satellite is approximated into the non-linear equation. To solve the simultaneous approximated radiative transfer equation which express the radiative transfer process of the radiant energy radiated from the sea surface to the satellite is approximated into the nonlinear equation. To solve the simultaneous approximated radiative transfer equation at each channel, the constrained non-linear optimization technique is adopted. To define the coefficients of the approximated radiative transfer equation and the constraints, the satellite detected radiance and the total transmittance are computed from the 1350 kinds of simulated atmosphere / surface models via radiative transfer code. The verification from the simulated data show the sufficient result.

  • PDF

등가재령을 활용한 초고성능 콘크리트의 압축강도 예측식 제안 (A Proposal for Predicting the Compressive Strength of Ultra-high Performance Concrete Using Equivalent Age)

  • 백성진;박재웅;한준희;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.149-150
    • /
    • 2023
  • This study proposes the most suitable strength prediction model equation for UHPC by calculating the apparent activation energy of UHPC according to the curing temperature and deriving the integrated temperature and compressive strength prediction equation. The results are summarized as follows. The apparent activation energy was calculated using the Arrhenius function, which was calculated as 21.09 KJ/mol. A model equation suitable for UHPC was calculated, and when the Flowman model equation was used, it was confirmed that it was suitable for the properties of UHPC using a condensation promoting super plasticizing agent.

  • PDF

Correlation Between Arrhenius Equation and Binding Energy by X-ray Photoelectron Spectroscopy

  • Oh, Teresa
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권6호
    • /
    • pp.329-333
    • /
    • 2013
  • SiOC films were prepared by capacitively coupled plasma chemical vapor deposition, and the correlation between the binding energy by X-ray photoelectron spectroscopy and Arrhenius equation for ionization energy was studied. The ionization energy decreased with increase of the potential barrier, and then the dielectric constant also decreased. The binding energy decreased with increase of the potential barrier. The dielectric constant and electrical characteristic of SiOC film was obtained by Arrhenius equation. The dielectric constant of SiOC film was decreased by lowering the polarization, which was made from the recombination between opposite polar sites, and the dissociation energy during the deposition. The SiOC film with the lowest dielectric constant had a flat surface, which depended on how carbocations recombined with other broken bonds of precursor molecules, and it became a fine cross-linked structure with low ionization energy, which contributed to decreasing the binding energy by Si 2p, C 1s electron orbital spectra and O 1s electron orbital spectra. The dielectric constant after annealing decreased, owing to the extraction of the $H_2O$ group, and lowering of the polarity.

라이다 측정을 이용한 나셀 풍속계 보정식 제안 (Calibration Equation for Nacelle Anemometer Derived by LIDAR Measurements)

  • 김현구;안해준;양승주;박우재;김석우
    • 신재생에너지
    • /
    • 제9권1호
    • /
    • pp.12-16
    • /
    • 2013
  • The nacelle anemometer mounted behind the blade roots of a wind turbine measures distorted wind speed comparable with free-stream wind because of the wake effects caused dependent upon the operation of the wind turbine and the rotation of its blades. The field campaign was carried out to measure free-stream wind speed at a height identical to the height of the nacelle anemometer by deploying a ground-based remote-sensing equipment, LIDAR. It is derived that a third-order polynomial equation for correcting wind speed measured by the nacelle anemometer to undistorted free-stream wind speed incident to a wind turbine. It is anticipated that the derived correction equation enables wind speed measured by the nacelle anemometer to be used as a precise input for a wind turbine performance test and for developing an active control logic.

공기열원 히트펌프를 위한 공기식 지중 열교환기(GAHX) 설계 및 분석 연구 (Ground Air Heat Exchanger Design and Analysis for Air Source Heat Pump)

  • 이광섭;류남진;강은철;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권2호
    • /
    • pp.1-6
    • /
    • 2016
  • A ground air heat exchanger (GAHX), also called earth air heat exchanger is a useful technology to be integrated with other renewable energy technologies. In this study, ground-air heat exchanger system for the air source heat pump is introduced. The purpose of this study is to design the volumetric flow rate and the length of GAHX system. A GAHX length model equation has been developed and used for calculation. GAHX thermal efficiency are recommended as 75% and 85% in order to optimize pipe length. $2,750m^3/h$, $2,420m^3/h$ of volumetric flow rate on 88.3m, 111.7m length are suggested for providing 7.5kW thermal capacity. And the number of path is recommended more than two to minimize pressure drop. For future study, advanced model equation study with ground thermal behavior and a more efficient GAHX design will be considered.