• 제목/요약/키워드: Energy Efficiency Ventilation

검색결과 129건 처리시간 0.026초

취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구 (A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping)

  • 김세환;김동규;박종일
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

창호의 개폐조절을 기반으로 한 리스펀시브 뉴메틱 파사드 (Responsive Pneumatic Facade with Adaptive Openings for Natural Ventilation)

  • 이지선;이현수
    • 대한건축학회논문집:계획계
    • /
    • 제33권12호
    • /
    • pp.29-39
    • /
    • 2017
  • The building skins are important architectural elements in both functional and aesthetical aspects. This study focuses on developing a responsive facade with autonomous opening and closing behaviors in accordance with environmental conditions and user requirements for natural ventilation for the office building. The pneumatic ETFE panels are applied as the skin materials taking advantage of the efficiency of the inflatable skin of lightness, architectural performance and sustainable material properties. The biomimetic design methodology is taken for its innovative and visionary concept for the facade design. The interpretation of the building facade in analogy to natural organisms delivers functional and aesthetic characters. By exploring the structural movements of the plant pores, the facade control is developed to be autonomous by the parameter values. The facade opening and closing configurations are derived through parametric modeling and visualization programming. Through the application of this study, expected results are to improve user comfort and energy efficiency.

초등학교 실내공간 디자인의 환경친화적 특성에 관한 연구 - 부산시와 오사카시 초등학교 사례를 중심으로 - (A Study on the ecological design elements of elementary school interior - Focused on the elementary schools of Osaka, Japan and Busan, Korea -)

  • 윤지영;송주은
    • 한국실내디자인학회논문집
    • /
    • 제14권3호
    • /
    • pp.46-54
    • /
    • 2005
  • This study explored how the elementary schools provided proper interior environments to the students in terms of ecological aspects. 14 cases-7 in Busan and 7 in Osaka which were newly built or remodelled since 2000 were selected. These schools were analyzed based on the eco-school guideline suggested In the former study. The guideline categorizes into three parts: 1) energy efficiency related with lighting, ventilation, heating and insulation, 2) greening, 3) sustainability including recycling water system and use of environmentally friendly materials. The results showed that Korean schools require more systematic planning for natural lighting, ventilation, Insulation, greening and new water system while Japanese schools need use of environmentally friendly materials and consideration for natural lighting, insulation and interior greening. Especially, natural lighting and natural ventilation through roof window, atrium, wind tower and use of natural insulation and blind window system should be basically considered at the Initial planning. Also, this study reveals that ecological approach including greening and natural lighting with various architectural form should be applied in future elementary school design to make the school environment more agreeable and economical.

환기 병용형 냉난방 시스템 설계 및 현장 적용 사례 연구 (A Case Study of Hybrid Air Conditioning and Ventilation System)

  • 이홍철;황인주;신현준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.89-94
    • /
    • 2008
  • In this study it was evaluated that hybrid air conditioning and ventilation system to reduce energy consumption and keep on comfortable indoor environment in an underground shopping center. Room temperature by hybrid HAVC system was controled as $1.8{\sim}2.1^{\circ}C$ low and indoor humidity was controled as $4.1{\sim}5.0%RH$ low, and response was fast in $2.0{\sim}2.5$ times compared with conventional system. And also transportation efficiency of hybrid HVAC system was improved in about 27%, and total energy consumption rate of hybrid HVAC system is decreased in 16% compared with conventional system.

  • PDF

강제환기식 돈사의 환기 효율성 분석을 위한 CFD 모델 개발 (Development of a CFD Model to Study Ventilation Efficiency of Mechanically Ventilated Pig House)

  • 서일환;이인복;홍세운;황현섭;;유재인;권경석;하태환;김현태
    • 한국농공학회논문집
    • /
    • 제50권1호
    • /
    • pp.25-37
    • /
    • 2008
  • When livestock facilities in Korea have been changed larger and denser, rearing conditions have been getting worse and the productivity of animal production have been decreased. Especially in the cold season, the minimized ventilation has generally been operated to save energy cost in Korea resulting in very poor environmental condition and high mortality. While the stability, suitability, and uniformity of the rearing condition are the most important for high productivity, the ventilation configuration is the most important to improve the rearing condition seasonally. But, it is so difficult to analyze the internal air flow and the environmental factors by conducting only field experiment because the weather condition is very unpredictable and unstable as well as the structural specification can not be easily changed by the researchers considering cost and labor. Accordingly, an aerodynamic computer simulation was adopted to this study to overcome the weakness of conducting field experiment and study the aerodynamic itself. It has been supposed that the airflow is the main mechanism of heat, mass, and momentum transfers. To make the simulation model accurately and actually, simplified pig models were also developed. The accuracy of the CFD simulation model was enhanced by 4.4 % of errors compared with the data collected from field experiments. In this paper, using the verified CFD model, the CFD computed internal rearing condition of the mechanically ventilated pig house were analyzed quantitatively as well as qualitatively. Later, this developed model will be computed time-dependently to effectively analyze the seasonal ventilation efficiency more practically and extensively with tracer gas decay theory.

공동주택 지하주차장의 자연환기성능 향상방안에 관한 연구 (A Strategies to Improve the Natural Ventilation Performance at Underground Parking Lot in Multi-Residential Buildings)

  • 서정민;이중훈;송종의;정정화;송두삼
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.153-163
    • /
    • 2011
  • Energy efficiency and indoor air quality have become main issue to develop healthy and sustainable building in these days. As an effort to reduce the energy consumption in multi-residential building, many attempts as like passive design strategies and renewable energy as well as active control method are tried. However, underground parking lot in multi-residential building seldom adopt the sustainable strategies and only mechanical system is installed as usual. Moreover, the mechanical system installed in underground parking lot is rarely operated due to the electric demand for operation after completion. In this study, as an energy efficient measure, natural ventilation system using stack effect as a driving force for underground parking lot will be proposed and the performance of the suggested system will be analyzed by simulation method.

고속버스의 환기구 형태에 따른 환기량 분석 (Analysis on the Ventilation Rate of Express Bus according to the Geometry of Vent)

  • 신인환;유호천
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.174-178
    • /
    • 2011
  • This paper deals with the free cooling system of express bus using natural energy source in order to improve the room air quality and save cooling energy. In an express bus, there are may passengers in unit area, requiring the improvement of air quality and giving higher energy saving efficiency. Particularly, the express buses running fast make it easy to take in outdoor air at a flow rate controllable with a damper mechanism. This paper proposes the analysis on the air flow achieved by a damper controlled vertically and horizontally in order not to deteriorate the ride comfort of the passengers.

  • PDF

전문가 설문조사를 통한 에너지 효율적인 병원시설을 위한 중요한 영향요소의 분석 (An Analysis of Important Factors for Energy Efficient Healthcare Facilities on Experts' Survey)

  • 최여진;최율
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.45-50
    • /
    • 2017
  • Purpose: There have been more researches focused on eco-friendly construction practices in order to save energy consumed and these practices have been extensively applied for constructing buildings. However, researches on energy consumption saving and efficiency for hospital facilities have been still insufficient. This research aims to draw factors that affect energy efficiency of hospital buildings through literature reviews and perform an expert-survey using AHP(Analytical Hierarchy Process) method in order to analyze the importances and priorities of these energy efficient factors. Method: Using the AHP method, this paper suggests the importances and priorities of factors to affect energy efficiency in hospital buildings. The survey of experts at a architectural design and a construction management companies was conducted via e-mail and mail. Result: As a result, factors of window and door, insulation, ventilation, and natural lighting turned out relatively important as respectively 0.104, 0.102, 0.101, and 0.095 n the energy efficiency in hospital buildings, while factors of artificial lighting, geothermal, solar heat, and control did unimportant as 0.027, 0.033, 0.043, and 0.053.

크랭크실 환기장치의 오일 분리효율에 관한 연구 (A Study on Oil Separation Performance of Crank-Case Ventilation System)

  • 서준호;나병철;김진용;박승욱;임대순
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.144-150
    • /
    • 2008
  • This research aims to develop parts for advanced fuel/oil filtering re-circulation applicable to this kind of regulation proof engines. These parts can playa role of converting traditional air emission type crankcase into recovery type crankcase so that the engine can deal with environmental regulations, which do not allow minimal amount of toxic gas discharge. For the experiment, test method and specially made testing equipment are prepared. The results showed that oil separation efficiency of the cone type CCV(Crank Case Ventilation) system was higher than one of cylinder type both in bench test and in engine.

지하도 상가 냉난방.환기 시스템의 난방운전 특성 연구 (An Experimental Study on the Heating Characteristics of HVAC Systems for Shopping Center in Underground Passage)

  • 이홍철;황인주;김태형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2989-2994
    • /
    • 2008
  • The shopping center in underground passage for efficient space utilization is increased in urban area. This study describes operation characteristics of HVAC systems with ventilation and individual heating and cooling unit for shopping center in underground passage. In order to compare energy saving, thermal environment and installation space, etc., an integrated simulator with heat production and distribution system was designed and constructed. Energy delivery efficiency is improved over 20%, and energy saving of the hybrid system is calculated as over 30% compared to conventional all air type in the case of heating. And also the results showed that humidity decreased about $5{\sim}6%$, also characteristics of thermal control is improved over 34%.

  • PDF