• Title/Summary/Keyword: Energy Diagram

Search Result 307, Processing Time 0.026 seconds

Design of DC Side Voltage and Compensation Analysis of THD for Shunt Power Quality Controller under System Load of Rectifier with R-L Load

  • Zhao, Guopeng;Han, Minxiao
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.30-40
    • /
    • 2015
  • For a shunt power quality controller (SPQC) the DC side voltage value which is closely related to the compensation performance is a significant parameter. Buy so far, very little discussion has been conducted on this in a quantitative manner by previous publications. In this paper, a method to design the DC side voltage of SPQC is presented according to the compensation performance in the single-phase system and the three-phase system respectively. First, for the reactive current and the harmonic current compensation, a required minimal value of the DC side voltage with a zero total harmonic distortion (THD) of the source current and a unit power factor is obtained for a typical load, through the equivalent circuit analysis and the Fourier Transform analytical expressions. Second, when the DC side voltage of SPQC is lower than the above-obtained minimal value, the quantitative relationship between the DC side voltage and the THD after compensation is also elaborated using the curve diagram. Hardware experimental results verify the design method.

Partial Miscibilities in Binary Solutions with Two Kinds of Specific Interactions (두 종류의 특정상호작용을 갖는 이성분 용액의 부분 혼합도)

  • Jung, Hae-Young
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.2
    • /
    • pp.111-117
    • /
    • 2016
  • In this article, new Gibbs free energy of mixing is derived when there are specific interactions between solvent-solute molecules and between solute-solute molecules in binary solutions. It is asssumed that a probability of specific interactions satisfies a binomial distribution. Using this Gibbs free energy of mixing, we investigate possible types of partial miscibilities and show that Ω-shaped temperature-composition phase diagrams can exist. We calculate Ω-shaped temperature-composition phase diagram of water-2-butanol system and compare that with result calculated by the method of Hino5 et al. and the experimental data.

A Study on FTA of Off-Site Packaged Hydrogen Station (Off-Site 패키지형 수소충전소의 FTA 분석)

  • SEO, DOO HYOUN;KIM, TAE HUN;RHIE, KWANG WON;CHOI, YOUNG EUN
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.1
    • /
    • pp.73-81
    • /
    • 2020
  • For the fault tree analysis (FTA) analysis of the packaged hydrogen filling station, the composition of the charging station was analyzed and the fault tree (FT) diagram was prepared. FT diagrams were created by dividing the causes of events into external factors and internal factors with the hydrogen event as the top event. The external factors include the effects of major disasters caused by natural disasters and external factors as OR gates. Internal factors are divided into tube tailer, compressor & storage tank, and dispenser, which are composed of mistakes in operation process and causes of accidents caused by parts leakage. In this study, the purpose was to improve the hydrogen station. The subjects of this study were domestic packaged hydrogen stations and FTA study was conducted based on the previous studies, failure mode & effect analysis (FMEA) and hazard & operability study (HAZOP). Top event as a hydrogen leaking event and constructed the flow of events based on the previous study. Refer to "Off shore and onshore reliability data 6th edition", "European Industry Reliability Data Bank", technique for human error rate prediction (THERP) for reliability data. We hope that this study will help to improve the safety and activation of the hydrogen station.

Development and Application of Power System Stability Analysis Program Using OOP (개체지향기반 안정도 해석 프로그램 개발 및 적용)

  • 박지호
    • Journal of Energy Engineering
    • /
    • v.11 no.3
    • /
    • pp.194-202
    • /
    • 2002
  • In this paper, we simulate the power system transient stability of Kwang Yang steel works using object-oriented programming (OOP). OOP is a more flexible method than procedural programming. There are several advantages in dynamic system simulation using OOP, The maintenance and repair of program are easy because it is sufficient to modify necessary parts which correspond to the change of system without overall change of program. We have implemented a graphical man-machine interface (MMI) that can be used draw one-line system diagram and analyze power flow and dynamic stability. The implemented MMI also provide a graphical viewer that display dynamic stability analysis results by mouse event handling. The proposed method have been applied to Kwang Yang steel works network for on-line dynamic stability analysis. The dynamic behaviour of 17 synchronous generators and 25 synchronous motors has been studied in the Kwang Yang network.

On Statistical Properties of the Extreme Waves in Hong-do Sea Area During Typhoons (홍도 해역에서 태풍 중 극한파의 통계적 특성에 대한 연구)

  • Ryu Hwanajin;Kim Do Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.1
    • /
    • pp.47-55
    • /
    • 2004
  • In this paper, The statistical properties of ocean waves in the sea area of Hong-do, Korea are examined based on 1998-2002's wave data from a directional wave buoy. Wave data aquisition rate, mean wave heights, frequency of wave direction are summarized. Wave height and period scatter diagrams and n-year return period wave heights are estimated. Wave periods of maximum wave heights are also estimated. Large amplitude wave characteristics during the typhoon Prapiroon in 2000, Rusa in 2002 are also examined.

  • PDF

Crystallization from The Melt of 6Bi2O3.GeO2 Composition (6Bi2O3.GeO2 조성 융액의 결정화)

  • 김호건;김명섭
    • Journal of the Korean Ceramic Society
    • /
    • v.26 no.4
    • /
    • pp.479-486
    • /
    • 1989
  • According to the phase diagram, 6Bi2O3.GeO2 composition melts congruently at 93$0^{\circ}C$ and forms a stable ${\gamma}$-6Bi2O3.GeO2 crystal phase below the melting point. But when the melt of this composition was cooled at a rate 1-15$0^{\circ}C$/min without tapping by a glass rod or impurity addition, a metastable $\delta$-6Bi2O3.GeO2 crystal phase was formed. It is due to that as the nucleation energy barrier of $\delta$-6Bi2O3.GeO2 crystals, which have more open and defective structure, is lower than that of ${\gamma}$-6Bi2O3.GeO2 crystals. When impurities or ${\gamma}$-6Bi2O3.GeO2 crystals existed in the melt, stable ${\gamma}$-6Bi2O3.GeO2 crystal phase was formed at various cooling rate. It is because of that the impurities or the ${\gamma}$-6Bi2O3.GeO2 crystals role as a seed crystal and as a result the nucleation energy barrier of ${\gamma}$-6Bi2O3.GeO2 crystals is lowered.

  • PDF

White Light Emission from a Colloidal Mixture Containing ZnS Based Nanocrystals: ZnS, ZnS:Cu and ZnS:Mn

  • Lee, Jae Woog;Hwang, Cheong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.189-196
    • /
    • 2014
  • Water dispersible ZnS based nanocrystals: ZnS (blue), ZnS:Cu (green) and ZnS:Mn (yellow-orange) were synthesized by capping the surface of the nanocrystals with a mercaptopropionic acid (MPA) molecule. The MPA capped ZnS based nanocrystal powders were characterized by using XRD, HR-TEM, EDXS, FT-IR, and FT-Raman spectroscopy. The optical properties of the colloidal nanocrystals were also measured by UV/Vis and photoluminescence (PL) spectroscopies in aqueous solvents. The PL spectra showed broad emission peaks at 440 nm (ZnS), 510 nm (ZnS:Cu) and 600 nm (ZnS:Mn), with relative PL efficiencies in the range of 4.38% to 7.20% compared to a reference organic dye. The measured average particle sizes from the HR-TEM images were in the range of 4.5 to 5.0 nm. White light emission was obtained by mixing these three nanocrystals at a molar ratio of 20 (ZnS):1 (ZnS:Cu):2 (ZnS:Mn) in water. The measured color coordinate of the white light was (0.31, 0.34) in the CIE chromaticity diagram, and the color temperature was 5527 K.

Development of PSCAD User-defined Model for the Simulation of a PV Array (PV 어레이의 계통연계 모의를 위한 PSCAD 사용자 정의 모델 개발)

  • Ahn, Seon-Ju;Choi, Joon-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.134-139
    • /
    • 2011
  • Since large and small scale photovoltaic(PV) systems have been commercialized in many countries, it is necessary to assess the effects of PV systems on the electric power system. For this, the development of accurate simulation model of PV arrays is very important. PSCAD/EMTDC, a widely used simulation tool for analyzing the transient behavior of electrical apparatus and networks, does not have a standard model of a PV array. Therefore in order to simulate the PV array, users have to develop their own simulation model. However, the block-diagram-based model is very complicated, and it is hard to modify the model parameters. In this study, we develop the user-defined model of a PV array by using the Design Editor, which is provided by PSCAD program. The mathematical model of a PV array and the method to determine the parameters of nonlinear I-V equation are implemented in a Fortran code. The graphical user interface provides the users with easy and simple way to modify the PV array parameters and simulation conditions. In order to help the users, this model also provides the parameters of 10 commercial PV arrays.

Distribution of Biomass and Production in Man-made Pitch Pine Plantation in Korea (리기다 소나무 인공조림지의 물질생산량에 관한 연구)

  • Yim Kyong-bin;Lee Kyong-jae;Kwon Tae-ho;Park In-hyeop
    • Journal of Korea Foresty Energy
    • /
    • v.2 no.2
    • /
    • pp.1-12
    • /
    • 1982
  • To study tile comparison of aboveground biomass of Pinus rigida Mill. of 18-year-old, plantations located in Whaseong, Yuseong and Wanju district were selected. Ten sample trees in each district selected taking account of DBH distribution were felled carefully to minimize loss of branches and stem analysed by 1m lag segment sectioned from base . The tree height and DBH were measured for sample trees in total growing within $200m^2$ experimental plot. The diagram of oven-dry weight distribution of stem, branch and needle for each 1m segment was constructed. The logarithmic regression equations between dry weight of each component and the two variables, $DBH^2$ and tree height, combined term were presented. The standing crops in the sample stand was estimated to be as much as 23.88, 54.09 and 42.68 tons of dry matter, above ground , per ha in Whaseong, Yuseong anf Wanju district respectively. Annual net production was estimated at 253,657 and 3.65 tons per ha per year respectively. The net assimilation rate was 1.65,1.95 and 1.81 kg/kg/yr in Whaseong, Yuseong and Wanju district respectively. The efficency of leaf to produce stem was 0.99, 1.12 and 1.30 kg/kg/yr respectively.

  • PDF

Experimental exergy assessment of ground source heat pump system

  • Ahmad, Saif Nawaz;Prakasha, Om
    • Advances in Energy Research
    • /
    • v.6 no.2
    • /
    • pp.161-172
    • /
    • 2019
  • The principal intention of this experimental work is to confer upon the exergy study of GSHP associated with horizontal earth heat exchanger for space heating. The exergy analysis recognizes the assessment of the tendency of various energy flows and quantifies the extensive impression of inefficiencies in the system and its components. Consequently, this study intends to provide the enlightenment for well interpretation of exergy concept for GSHP. This GSHP system is composed of heat pump cycle, earth heat exchanger cycle and fan coil cycle. All the required data were measured and recorded when the experimental set up run at steady state and average of the measured data were used for exergy investigation purpose. In this study the rate at which exergy destructed at all the subsystems and system has been estimated using the analytical expression. The overall rational exergetic efficiency of the GSHP system was evaluated for estimating its effectiveness. Hence, we draw the exergy flow diagram by using the various calculated results. The result shows that in the whole system the maximum exergy destruction rate component was compressor and minimum exergy flow component was earth heat exchanger. Consequently, compressor and earth heat exchanger need to be pay more attention.