• 제목/요약/키워드: Energy Cost

검색결과 4,577건 처리시간 0.034초

에너지 절약형 건축물 설계를 위한 대학 강의동 형태별 에너지 성능 비교에 관한 연구 (An Energy Performance Comparison of University Lecture Facilities for Energy Saving Building Design)

  • 김태훈;서지효;추승연
    • 대한건축학회논문집:계획계
    • /
    • 제34권11호
    • /
    • pp.105-112
    • /
    • 2018
  • Global environmental problems are growing, and the importance of buildings with high energy consumption has been emphasized. In Korea, the Ministry of Land, Transport and Maritime Affairs has been promoting the mandatory zero energy building since 2020, and guidelines related to the zero energy building have been developed. In addition, based on the "Energy-saving Design Criteria for Buildings" of the "Green Building Promotion Act" in Korea, the standards for energy-saving design are specified and the energy saving plan is written. Besides, the 'Energy-saving construction standards for eco-friendly houses' also specify insulation, machinery, equipment, and sunshade. Also, there is little consideration about the cost such as construction cost and material cost which should be considered important in the construction stage. Therefore, this study aims at analysis of building type and energy performance versus materials for energy saving building design considering energy performance in planning aspect of initial design stage. In this study, because the variables can not be neglected in this study, it is selected as the lecture facility of the 'K' university campus building which can consider the remaining factors except the passive design element as the control variable, Energy performance analysis.

공기압축기 소비에너지 평가에 관한 연구 (A Study on the Evaluation of Energy Consumption of the Air Compressor)

  • 장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권2호
    • /
    • pp.38-44
    • /
    • 2020
  • Various efforts have been initiated to reduce the energy consumption of the compressor as it is one of the approaches to saving a large portion of the fixed cost of the production site. Various results of reducing the energy consumption of the compressor have been reported, but to reduce the energy consumption of the compressors fundamentally, regular management of the compressor should ensure optimum operation. This requires periodic on-site visits by experts, but is often overlooked as a cost issue, resulting in the use of the compressor in low-efficiency conditions. Thus, it is necessary to develop a low-cost evaluation technology for compressor condition monitoring and efficiency analysis to ensure that the compressor is always driven at the optimum efficiency without imposing undue burden on the compressor user. In this study, a sensor was installed at the inlet, outlet, and power supply of the compressor, and a method for evaluating the energy consumption of the compressor using the minimum sensor was derived. The experimental results are presented to show the validity of the proposed method. It was confirmed that the energy consumption of the compressor can be easily as well as efficiently evaluated by using the method developed in this study.

신.재생에너지원 발전전력 차액지원을 위한 현행 기준가격의 재산정 (Reappraisal of Feed-In Tariffs of Electricity Generating from New and Renewable Energy Sources)

  • 김은일;김건훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.281-286
    • /
    • 2008
  • Current feed-in tariffs(FIT) of Electricity generating from new and renewable energy sources are reappraised with the corrected formula of levelized generation cost(LGC) of utility power. The LGC of new and renewable electricity should be formulated in explicitly reflecting the capital cost and corporate tax during the economic life cycle based on its realistic application data. An applicable term of the FITs should, especially, be equal to the economic life cycle. The revised FITs issued in 2006 were, however, derived from the incorrect formula described in the study of KERI(Korea Electrotechnology Research Institute), and consequently misestimated. The reappraisal values for FIT of new and renewable electricity were shown and interpreted in this paper. An FIT of PV more than 30 kW, for example, should be 972.86 won/kWh instead of current 677.38 won/kWh increasing 43.6%. An upward revision of other FITs for new and renewable electricities should also be required in the range of 8.6% to 47.3%.

  • PDF

앉은 자세에서 능동적 체간 훈련이 초기 뇌졸중 환자의 균형과 에너지 소모에 미치는 효과 (The Effect of Active Trunk Training in Sitting Position on Balance and Energy Consumption in Early Stroke Patients)

  • 최종덕;정경만
    • 대한물리의학회지
    • /
    • 제12권4호
    • /
    • pp.93-103
    • /
    • 2017
  • PURPOSE: This study aimed to determine the effect of active trunk training in the sitting position on balance and energy consumption in early stroke patients. METHODS: The subjects of this study were twenty four early stroke patients were recruited and randomly divided into two groups; experimental group (n=12) and control group (n=12). The subjects in the experimental group participated in active trunk training (20 min) and conventional physical therapy (20 min) five times a week for four weeks. The control group conducted general balance exercise (20 min) and conventional physical therapy (20 min) five times a week for four weeks. The outcomes were assessed using the Berg balance scale, Timed up and go test and energy cost and physiological cost index. RESULTS: Both groups showed a significant increase in their Berg balance scale and significant decrease in their Timed up and go test score, and energy cost and physiological cost index (p<.05). Compared to the control group, the experimental group experienced a greater increase in the Berg balance scale (p<.05) and a larger decrease in the timed up and go test score, and energy cost and physiological cost index (p<.05). CONCLUSION: We suggest that active trunk training in the sitting position may be effective in improving balance and energy consumption in early stroke patients. Thus, active trunk training is important for such patients. Further studies are needed to better understand the effectiveness of trunk training in early stroke patients.

플래시 기반 임베디드 DBMS의 전력기반 질의 최적화를 위한 비용 모델 (Cost Models of Energy-based Query Optimization for Flash-aware Embedded DBMS)

  • 김도윤;박상원
    • 전자공학회논문지CI
    • /
    • 제45권3호
    • /
    • pp.75-85
    • /
    • 2008
  • 임베디드 시스템에서 데이터베이스의 사용이 증가하고 있으며 이의 임베디드 시스템의 저장 장치로 낸드 플래시 메모리가 널리 사용되고 있다. 기존 데이터베이스 시스템의 질의 처리기의 최적화기는 저장 시스템을 디스크로 가정하고 설계되어 있다. 플래시 메모리는 디스크와는 달리 덮어 쓰기 연산을 하기 위해서는 기존 블록을 소거한 후 쓰기 연산을 해야하는 부담이 있다. 그러므로 기존 디스크 기반의 질의 최적화기는 임베디드 시스템에 적합하지 않다. 특히 임베디드 시스템은 전력 소모량을 최소화해야 하나 플래시에서의 빈번한 쓰기 연산은 추가적인 소거 연산으로 인한 전력 소비를 증진시킨다. 본 논문은 임베디드 데이터베이스에서 전력 기반 비용 모델을 새롭게 제시하고, 디스크 기반 비용 모델과 비교하여 제시한 비용 모델과의 차이를 보인다.

An Optimal Energy Storage Operation Scheduling Algorithm for a Smart Home Considering Life Cost of Energy Storage System

  • Yan, Luo;Baek, Min-Kyu;Park, Jong-Bae;Park, Yong-Gi;Roh, Jae Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1369-1375
    • /
    • 2017
  • This paper presents an optimal operation scheduling algorithm for a smart home with energy storage system, electric vehicle and distributed generation. The proposed algorithm provides the optimal charge and discharge schedule of the EV and the ESS. In minimizing the electricity costs of the smart home, it considers not only the cost of energy purchase from the grid but also the life cost of batteries. The life costs of batteries are calculated based on the relation between the depth of discharge and life time of battery. As the life time of battery depends on the charge and discharge pattern, optimal charge and discharge schedule should consider the life cost of batteries especially when there is more than one battery with different technical characteristics. The proposed algorithm can also be used for optimal selection of size and type of battery for a smart home.

Techno-economic assessment of a very small modular reactor (vSMR): A case study for the LINE city in Saudi Arabia

  • Salah Ud-Din Khan;Rawaiz Khan
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1244-1249
    • /
    • 2023
  • Recently, the Kingdom of Saudi Arabia (KSA) announced the development of first-of-a-kind(FOAK) and most advanced futuristic vertical city and named as 'The LINE'. The project will have zero carbon dioxide emissions and will be powered by clean energy sources. Therefore, a study was designed to understand which clean energy sources might be a better choice. Because of its nearly carbon-free footprint, nuclear energy may be a good choice. Nowadays, the development of very small modular reactors (vSMRs) is gaining attention due to many salient features such as cost efficiency and zero carbon emissions. These reactors are one step down to actual small modular reactors (SMRs) in terms of power and size. SMRs typically have a power range of 20 MWe to 300 MWe, while vSMRs have a power range of 1-20 MWe. Therefore, a study was conducted to discuss different vSMRs in terms of design, technology types, safety features, capabilities, potential, and economics. After conducting the comparative test and analysis, the fuel cycle modeling of optimal and suitable reactor was calculated. Furthermore, the levelized unit cost of electricity for each reactor was compared to determine the most suitable vSMR, which is then compared other generation SMRs to evaluate the cost variations per MWe in terms of size and operation. The main objective of the research was to identify the most cost effective and simple vSMR that can be easily installed and deployed.

CCU 시스템을 통한 균등화 수소원가 및 재무적 위험도 분석 (Analysis of Levelized Cost of Hydrogen and Financial Performance Risk by CCU System)

  • 손민희;이흥구;김경남
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.660-673
    • /
    • 2022
  • In achieving carbon neutrality and the hydrogen economy, the estimation of H2 cost is critical in terms of CCU technologies. This study analyzes LCOH of hydrogen produced by the carbon utilization unit with methane reforming and CO2 from thermal power plant. LCOH for H2 made with CO is estimated in three ways of Joint Cost Allocations with financial performance risk assessment. Regarding cost analysis, the zero value of LCOH is $6,003/ton. We found that the CCU technology has economic feasibility in terms of profitability. The sensitivity analysis result shows that the input ratio is more influential to the LCOH than other variables. Risk analysis presents the baseline price of zero value of LCOH - $8,408/ton, which is higher than the cost analysis - $6,003/ton. Mainly, the price variability of natural gas primarily affects the LCOH. The study has significant value in analyzing the financial performance risks as well as the cost of H2 produced by a Plasma-based CCU system.

사회적 비용을 고려한 저탄소 전원구성의 시나리오 분석 (Scenario Analysis of Low-Carbon Generation Mix Considering Social Costs)

  • 박종배;조영탁;노재형
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.173-178
    • /
    • 2018
  • This study organizes scenarios on the power supply and demand plans considering the uncertainties and the portion of distributed energy resources. In analysing the scenarios, it estimates total electricity supply cost in the social aspect, natural gas demand and air pollutants emission including carbon dioxide. Also the analysis is performed to estimate the marginal cost of carbon dioxide reduction for the fuel switching from coal to liquified natural gas. In result, the social cost could be decreased by replacing some portion of renewable energy by LNG-based combined heat and power and delaying the construction of large base-load generators such as coal and nuclear plants. The marginal carbon dioxide reduction cost by fuel switching is in plausible range for fuel switching to be an option for carbon dioxide emission reduction when the social cost is considered.

LCA 및 LCC를 고려한 환경친화적 리모델링의 평가방법에 관한 연구 (A Study on the Evaluation Method of Green Remodeling Considering LCA and LCC)

  • 이관호;김남규;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제23권1호
    • /
    • pp.57-67
    • /
    • 2003
  • This study aims to presents Evaluation Method of Green Remodeling that analyze the value of environment through expense, using the method of life cycle cost and life cycle assessment simultaneously. The results of this study are summarized as follows. Evaluation Model developed in this study can convert economical value of environment into cost by integrating. In addition, the model can apply as a useful tool to estimation of economical design alternative as well as quantification of environmental loads and costs. Evaluation Model presented In this study observe energy consumption and the environmental load emission with qualification, it can forecast effect of environmental cost that cost estimation is expected to be added to energy cost rate by being possible. Synthetically, when Estimation Model and computer program that developed in this study is applies to the construction industry; reasonable management of environmental load is convenient at each step of Green Remodeling. In addition, at preliminary design phase, practical use may be possible by reasonable yardstick about various alternatives and improvement of design alternatives likewise by grasping environmental effect.