• Title/Summary/Keyword: Energy Consumption Rate

Search Result 1,027, Processing Time 0.03 seconds

Effect of interval exercise versus continuous exercise on excess post-exercise oxygen consumption during energy-homogenized exercise on a cycle ergometer

  • Jung, Won-Sang;Hwang, Hyejung;Kim, Jisu;Park, Hun-Young;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.23 no.2
    • /
    • pp.45-50
    • /
    • 2019
  • [Purpose] The purpose of this study was to confirm that the difference in excess post-exercise oxygen consumption (EPOC) during exercise of the spending the same calories between the continuous and interval exercise. [Methods] Thirty-four healthy college students who did not regularly exercise volunteered to participate in our study. Continuous exercise was performed on an ergometer for 30 min at 60% of maximal oxygen consumption (VO2 max). Interval exercise was performed on a cycle ergometer at 80% VO2 max for 2 min initially, followed by 40% VO2 max for 1 min, and 80% VO2 max for 3 min. This was repeated six times for a total of 26 min. [Results] The major findings were as follows: (1) energy consumption during exercise was not significantly different between continuous exercise and interval exercise groups; (2) EPOC was higher in interval exercise than in continuous exercise for all dependent variables (i.e., total oxygen consumption, total calories, summation of heart rate); and (3) there were no significant differences in the lipid profile between continuous and interval groups. [Conclusions] Our study confirmed that after equalizing energy expenditure for continuous and interval exercise on a cycle ergometer in subjects in their twenties, interval exercise results in higher EPOC than continuous exercise. These data suggest that interval exercise may be more effective than continuous exercise in reducing body fat, for a given amount of energy expenditure.

Study of Fuel Consumption Characteristics and Regenerative Braking Recovery Rate in a TMED Type Parallel Hybrid Electric Vehicle (TMED방식 병렬형 하이브리드 차량의 회생제동 회수율 및 연비 특성 연구)

  • Chung, Jin Ho;Kim, Jin Su;Kim, Ju Whan;Lee, Jin Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.485-494
    • /
    • 2016
  • In this work, we conducted a study of fuel consumption characteristics and regenerative braking recovery rate by conducting an experiment using a TMED type parallel hybrid electric vehicle. As regenerative braking technology is considered essential to improve the energy efficiency of the hybrid vehicle, it is necessary to conduct research on the regenerative braking system. Therefore, the electrical characteristics, current balance, and fuel consumption were investigated using an EC type chassis dynamometer with experimental conditions as per IM240 mode. From the results, it was observed that when the initial SOC condition was lower, the engine operating time of the hybrid vehicle increased, and the energy efficiency decreased. While operating in the driving mode characteristics condition and the driving characteristics condition, the difference in the average fuel consumption was not significant. However, after completion of the experiment, there was a difference in the engine operation.

Reducing Method of Energy Consumption of Phase Change Memory using Narrow-Value Data (내로우 값을 이용한 상변화 메모리상에서의 에너지 소모 절감 기법)

  • Kim, Young-Ung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 2015
  • During the past 30 years, DRAM has been used for the reasons of economic efficiency of the production. Recently, PRAM has been emerged to overcome the shortcomings of DRAM. In this paper, we propose a technique that can reduce energy consumption by use of a narrow values to the write operation of PRAM. For this purpose, we describe the data compression method using a narrow value and the architecture of PRAM, We also experiment under the Simplescalar 3.0e simulator and SPEC CPU2000 benchmark environments. According to the experiments, the data hit rate of PRAM was increased by 39.4% to 67.7% and energy consumption was reduced by 9.2%. In order to use the proposed technique, it requires 3.12% of space overhead per word, and some additional hardware modules.

An Experimental Study on the Performance and the Exhaust Emissions of Gasoline Engine Using Water-Gashol Blends as a Fuel (물-가스홀 혼합물을 연료로 사용한 가솔린기관의 성능 및 배기성분에 관한 실험적 연구)

  • 노상순;배명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.25-38
    • /
    • 1984
  • Since the energy shock in 1973, there have been wide studies for the developments of the alternative energy source, the rationalization of the energy utilization and the energy economy because of the recognition of the limitation of energy source all over the world. This study is experimentally examined in and compared with the engine performance of output, torque and fuel consumption rate, and the exhaust emissions with the change of engine rmp in the cases of using water-gashol blends, gashol and gasoline as a fuel in a conventional 4 cycle 4 cylinder gasoline engine. In the case of using water-gashol blends, it is installed by the exhaust manifold pipe into the intake manifold, and water is injected from nozzle fitted up the air horn of the carburetor. The results are obtained as follows; 1. In the case of an addition with water, the engine output and the torque are little difference with the case of gasoline. 2. The fuel consumption rate is decreased as compared with the case of gasoline. Especially, the decrease in quantity is remarkable at the low rpm. 3. The exhaust emissions are remarkably decreased as compared with the case of gasoline. Especially, decreases of CO and HC in quantity are remarkable at the low rpm, and a decrease of No/sub x/ in quantity is remarkable at the high rpm. 4. There is a moderate condition of operation because the producing factors of NO/sub x/ and CO, HC are contrary to each other.

  • PDF

Performance Analysis of Switching Strategy in LTE-A Heterogeneous Networks

  • Peng, Jinlin;Hong, Peilin;Xue, Kaiping
    • Journal of Communications and Networks
    • /
    • v.15 no.3
    • /
    • pp.292-300
    • /
    • 2013
  • Nowadays, energy saving has become a hot topic and information and communication technology has become a major power consumer. In long term evolution advanced (LTE-A) networks, heterogeneous deployments of low-power nodes and conventional macrocells provide some new features, such as coverage extension, throughput enhancement, and load balancing. However, a large-scale deployment of low-power nodes brings substantial energy consumption and interference problems. In this paper, we propose a novel switching strategy (NS), which adaptively switches on or off some low-power nodes based on the instantaneous load of the system. It is compatible with the microcells' load balancing feature and can be easily implemented on the basis of existing LTE-A specifications. Moreover, we develop an analytical model for analyzing the performance of system energy consumption, block rate, throughput, and energy efficiency. The performance of NS is evaluated by comparison with existing strategies. Theoretical analysis and simulation results show that NS not only has a low block rate, but also achieves a high energy efficiency.

A study on energy efficiency improvement of waste-water treatment system by freeze concentration method (동결농축법을 이용한 폐수처리시스템의 에너지 효율 향상에 관한 연구)

  • Kim, Jung-Sik;Lim, Seung-Taek;Oh, Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.467-476
    • /
    • 2013
  • Freeze concentration method has advantages of high thermodynamic efficiency, low energy consumption and purified water re-use. In this study, freeze concentration waste-water system which was designed as the small and medium sized capacity was analyzed about the rate of electric power consumption and the daily treatment capacity to suggest the direction of system development. At first, power consumption and operation time of the system with fresh water precooler or without it was calculated by computer modeling and analysis. Subsequently, the change of design treatment capacity was applied to the system with fresh water cooler. As a result, the rate of electric power consumption was higher as 0.6 Wh/kg but daily treatment capacity increased in quantity as 19 % in the system with fresh water precooler. As design treatment capacity increased, the rate of electric power consumption was lower and daily treatment capacity was larger in quantity.

Experimental Study on Hydrogen Direct Reduction of Hematite in a Lab Scale Fluidized Bed Reactor by Estimating the Gas Consumption Rate

  • Hasolli, Naim;Jeon, Seong Min;Park, Young Ok;Kim, Yong Ha
    • Clean Technology
    • /
    • v.21 no.2
    • /
    • pp.96-101
    • /
    • 2015
  • Hematite reduction using hydrogen was conducted and the various process parameters were closely observed. A lab scale fluidized bed unit was designed especially for this study. The optimal values of the gas velocity, reduction time and temperature were evaluated. The values which indicated the highest reduction rate were set as fixed parameters for the following tests starting with the reduction time of 30 minutes and 750 ℃ of temperature. Among these variables the one with the highest interest was the gas specific consumption. It will tell the amount of the gas which is required to achieve a reduction rate of over 90% at the optimal conditions. This parameter is important for the scale up of the lab scale unit. 1,500 Nm3/ton-ore was found to be the optimal specific gas consumption rate at which the reduction rates exhibit the highest values for hematite.

Thermic Effect of Food and Macronutrient Oxidation Rate in Men and Women after Consumption of a Mixed Meal (성인 남녀의 식사성 발열효과 및 식후 영양소 산화율)

  • Kim, Myung-Hee;Kim, Eun-Kyung
    • Journal of Nutrition and Health
    • /
    • v.44 no.6
    • /
    • pp.507-517
    • /
    • 2011
  • The purpose of this study was to investigate the effects of gender on the thermic effect of food and substrate oxidation rate during 5 hours after a mixed meal. Twenty healthy college students (10 males and 10 females) aged 20-26 years participated in this study. The energy contents of the experimental diets were 775 kcal and 627 kcal for males and females respectively, which were 30% of individual energy requirements and were composed of 65/15/20% as the proportion of carbohydrate/protein/fat. Resting and postprandial energy expenditure and substrate oxidation rates were measured with indirect calorimetry in the fasting state and every 30 min for 5 hours after meal consumption. Thermic effects of food expressed as ${\Delta}AUC$ and TEF% were not significantly different between males and females. However, TEF% adjusted for body weight and fat-free mass in males (0.095% and 0.120%) were significantly lower than those in females (0.152% and 0.213%)(p < 0.05). The total amount of carbohydrate oxidized was significantly lower in males than that in females (58.6 vs. 86.6 mg/kcal energy intake/5 h, p < 0.05). In contrast, the total amount of fat oxidized was significantly higher in males than that in females after the meal (32.9 vs. 17.2 mg/kcal energy intake/5 h, p < 0.01). These results indicate that gender affects the thermic effects of food and the substrate oxidation rate after a meal. The results show that males use relatively less carbohydrate and more fat as an energy source after a meal than that of females.

A Study on the Application of District Heating System using Sewage Source (하수열원을 이용한 지역난방 적용성 검토)

  • Kim, Sang-Hun;Kim, Dong-Jin;Choi, Dong-Kyoo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.928-933
    • /
    • 2009
  • The purpose of this study is to examine the energy consumption, carbon dioxide emission & energy cost of district heating using sewage source. The annual TOE of heat pump using sewage source save 37.1 percent than city gas boiler. And annual carbon dioxide emission of heat pump cut down 41.3 percent than city gas boiler. If it charges the rate schedule for district heating to apartment resident, collected amount are 3,127,170 thousand won. As energy cost of heat pump & circulation pump are 1,378,072 thousand won. the profits are 1,749,098 thousand won. As payback period is 8.97years, applicability is low level. However, it has advantages in energy consumption, carbon dioxide emission & energy cost. Therefore, it needs to proceed through government assistance.

  • PDF

Data-centric Energy-aware Re-clustering Scheme for Wireless Sensor Networks (무선 센서 네트워크를 위한 데이터 중심의 에너지 인식 재클러스터링 기법)

  • Choi, Dongmin;Lee, Jisub;Chung, Ilyong
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.5
    • /
    • pp.590-600
    • /
    • 2014
  • In the wireless sensor network environment, clustering scheme has a problem that a large amount of energy is unnecessarily consumed because of frequently occurred entire re-clustering process. Some of the studies were attempted to improve the network performance by getting rid of the entire network setup process. However, removing the setup process is not worthy. Because entire network setup relieves the burden of some sensor nodes. The primary aim of our scheme is to cut down the energy consumption through minimizing entire setup processes which occurred unnecessarily. Thus, we suggest a re-clustering scheme that considers event detection, transmitting energy, and the load on the nodes. According to the result of performance analysis, our scheme reduces energy consumption of nodes, prolongs the network lifetime, and shows higher data collection rate and higher data accuracy than the existing schemes.