• 제목/요약/키워드: Energy Consumption Efficiency

검색결과 1,785건 처리시간 0.036초

마일드 하이브리드 차량용 복합형 에너지 저장장치의 성능개선에 관한 연구 (A Study on Performance Improvement of Hybrid Energy Storage System for Mild HEV)

  • 이백행;신동현;김희준
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1763-1769
    • /
    • 2007
  • To improve the cycle-life and efficiency of an energy storage system for HEV, a dynamic control system consisted of a switch between a battery and an ultracapacitor module is proposed, which is appropriate for mild hybrid vehicle with 42V power net. The switch can be controlled based on the status of the battery and the ultracapacitor module, and a control algorithm that could largely decrease the number of high charging current peak is also implemented. Therefore the cycle life of the battery can be improved such that it is suitable for a mild hybrid vehicle with frequent engine start-stop and regenerative-braking. Also, by maximizing the use of the ultracapacitor, the system efficiency during high current charging and discharging operation is improved. Finally, this system has the effects that improves the efficiency of energy storage system and reduces the fuel consumption of a vehicle. To verify the validity of the proposed system, this paper presented cycles test results of different energy storage systems: a simple VRLA battery, hybrid energy Pack (HEP, a VRLA battery in Parallel with Ultracapacitor) and a HEP with a switch that controlled by energy management system (EMS). From the experimental result, it was proved the effectiveness of the algorithm.

펌프의 효율측정 장비에 관한 연구 (Study on the Device for Pump Efficiency Measurement)

  • 배철오
    • 선박안전
    • /
    • 통권33호
    • /
    • pp.53-62
    • /
    • 2012
  • 펌프는 산업 및 건설현장에 급수, 냉난방 및 산업공정에서 다양하게 사용되고 있으며, 전체 국가 전력의 약 20%를 소비하고 있다. 하지만 에너지 낭비요소에 대한 관리는 거의 이루어지지 않고 있는 실정이다. 따라서 만일 효율이 저하된 상태로 펌프가 운전된다면 그의 에너지 낭비는 대단히 크게 된다. 펌프의 경우 초기 구입비용에 비해 사용하면서 발생하는 전력비용이 대단히 크기 때문에 이러한 낭비를 줄이기 위해서는 펌프의 효율을 정기적으로 측정하여 펌프의 운전 상태를 진단함으로써 펌프의 최적운전상태 및 교환주기 등을 제시할 수 있을 것이다. 본 연구에서는 펌프의 효율측정을 위해 열역학적 방법과 수력학적 방법(전통적인 방법)의 두 가지 방법으로 측정할 수 있는 장비에 대해서 소개하고 실제 펌프의 효율을 계산하여 그 유효성을 확인하였다.

  • PDF

공공하수처리장의 에너지 소비현황 및 효율성 평가 (Energy Efficiency Evaluation of Publicly Owned Wastewater Utilities)

  • 조을생;한대호;하종식
    • 환경정책연구
    • /
    • 제11권4호
    • /
    • pp.85-105
    • /
    • 2012
  • 국내 공공하수처리시설의 운영적 측면의 에너지 절감을 위한 방안을 모색하기 위해 에너지 효율성을 평가하였다. 하수처리시설의 에너지 사용에 영향을 미치는 변수를 통계적(유의수준 5%)으로 분석한 결과 유입하수량, 유입 COD, 유입 BOD, 고도처리비율, 유입 TN, 유입 TP, 실제 처리용량/설계용량 비율(가동률)로 나타나 국내 하수처리시설의 에너지 사용은 주로 하수 유입수의 성상 및 하수처리시설 가동률에 영향을 받는 것으로 분석되었다. 또한 회귀분석결과, 에너지 효율성이 평균(50 백분위수) 이상인 하수처리장 비율을 공법별로 살펴보면, A2O 공법을 적용하고 있는 하수처리시설이 상대적으로 에너지 효율성이 높게 운영된 것으로 평가되었으며 반면에 고도처리 공법에서는 분리막 고도처리, 2차 처리공법에서는 접촉산화법을 적용하고 있는 하수처리시설의 에너지 효율성 개선 노력이 상대적으로 더 많이 요구되는 것으로 나타났다. 그러나 보다 정확한 하수처리시설의 에너지 소비산정 및 분석을 위해서는 처리시설의 에너지 사용 모니터링 시스템 구축 및 에너지 소비시설의 정확한 DB 구축이 시급한 실정이다. 특히, 기존 하수도 통계자료에 i) 중계펌프 사용 전력량, ii) 단위공정별 전력량, iii) 처리수 장거리 방류시 펌프 전력사용량, iv) 대체에너지 생산량 및 활용현황 등에 대한 정확한 자료가 보완되어야 한다. 기초자료가 제대로 구축될 경우 유사한 하수처리시설의 에너지 소비 형태에 대해 구체적으로 비교 분석이 가능하며 분석결과를 활용하여 벤치마킹을 통한 각 하수처리장들의 특성에 따른 맞춤형 에너지 절감 방안이 수립될 수 있을 것이다.

  • PDF

오존용해탱크 구조 개선을 통한 효율적인 마이크로오존버블 생성 (Efficient Micro-Ozone-Bubble Generation by Improving Ozone Dissolution Tank Structure)

  • 박용화;이광희;장암
    • 대한환경공학회지
    • /
    • 제39권10호
    • /
    • pp.549-555
    • /
    • 2017
  • 본 연구는 오존용해탱크 구조에 따라 마이크로오존버블의 분포, 에너지 소비, 수처리 효율이 어떻게 변하는지를 알아보고자 하였다. 오존용해탱크 내부의 격판은 압력의 변화, 전단력, 선회유동을 발생시키고 이는 버블 직경의 크기에 변화를 준다. 버블 직경의 크기는 내부의 격판에 따라 10.5%까지 차이가 났다. 오존 버블 직경의 변화는 에너지 소비와 관련이 깊다. 오존 버블이 작아질수록 버블생성에너지는 높아지지만 용존 효율이 올라가면서 오존생산에너지는 줄어들게 된다. 따라서 버블생성에너지와 오존생산에너지의 합이 최소인 마이크로오존버블을 생성하는 오존용해탱크를 선정하여야 한다. 동일한 양의 오존가스을 방류수에 주입하기 위해 소비된 에너지는 내부의 격판에 따라 2.5%까지 차이가 났다. 하지만 수처리 효율까지 고려한다면 오존용해탱크 선정 조건이 달라진다. 오존 버블이 작아질수록 증가하는 자유라디칼이 수처리에 매우 효율적이기 때문이다. 동일한 오존주입농도에서도 내부의 격판에 따라 수처리 효율이 10.4%까지 차이가 났다. 따라서 수처리 효율과 에너지 효율을 고려하여 합리적인 마이크로오존버블을 생성하는 오존용해탱크 구조에 대하여 연구하였다.

하이브리드 보행보조장치의 에너지 소모도 비교분석 (Analysis of emergy comsumption for Hybrid Gait Orthosis)

  • 강성재;류제청;김규석;문무성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.814-817
    • /
    • 2004
  • It is a challenging task to make the paraplegic to walk with out the assist of the caregiver. So, we have developed various type of gait orthosis for paraplegic during the five years lately. The purpose of this study ultimately is energy consumption test of serveral type gait orthosis for developing the high efficiency gait orthosis. From the experimental results, the oxygen consumption rate were 6.9$\pm$3.3ml/kg in RGO gait, 5.3$\pm$1.3ml/kg in PGO, and 6.2$\pm$3ml/kg in HGO gait. The maximum hip flexion angle were 16$^{\circ}$ in RGO , 15$^{\circ}$ in PGO, and 47.5$^{\circ}$. in HGO. As a result It was found that. Hybrid Gait Orthosis need high energy consumption more than PGO for walking, but it is small weight and strengthened muscle.

  • PDF

Sales Energy Promotion Efficiency and Policy Utilization Plan for Energy Facilities

  • KWON, Lee-Seung;LEE, Woo-Sik;KWON, Woo-Taeg
    • 유통과학연구
    • /
    • 제18권9호
    • /
    • pp.67-75
    • /
    • 2020
  • Purpose: The purpose of this study is to enhance sales promotion efficiency for using solid refuse fuel facilities. Renewable energy technology using Solid Refuse Fuel (SRF) is an economic efficiency technology that recovers waste by burning various wastes. A survey on the pollutants discharged from the solid fuels facilities was investigated so that the SRF facilities could be expanded, distributed and reflected in the policy. Research design, data, and methodology: In this study, 9 business sites using SRF and Bio-SRF as main raw materials were investigated for 2 years. The characteristics of target business sites such as the type of fuel used, combustion method, combustion temperature, daily fuel consumption and environmental prevention facilities were studied. Results: The average pollution & ammonia concentration of Bio-SRF facilities was found to be 88.15% higher than that of SRF facilities. But the average acetaldehyde concentration of SRF facilities was found to be 88.15% higher than that of Bio-SRF facilities. Conclusions: The main issue is how much electric power generation using combustible materials affects air pollution. The waste recycling law provides the standard value according to the fuel property, but there is a considerable gap with the mixed fuel. Therefore, for efficient utilization of facilities using solid fuel products, additional research is needed to improve the distribution structure of exhaust pollutants is needed.

전기제품 에너지 소비효율의 통계적 양산 관리 방법에 대한 연구 (A Study on the Statistical Production Control of Energy Efficiency in Electric Product)

  • 전영호;김성돈
    • 한국경영공학회지
    • /
    • 제23권4호
    • /
    • pp.73-86
    • /
    • 2018
  • Most electric products produced during the manufacturing process are produced after design and mass production under a given control standard. In particular, the development phase should present the criteria for the production process by setting appropriate limits based on the performance being targeted. Even if the standard of performance is set considering the performance of the process, measuring the performance of the product after actual production results will cause nonconformities with the expected results. Among the performance of electrical products, Energy standards represented by energy consumption efficiency continue to be of importance, and are mandatory standards that correspond to national standards in most countries. Therefore, statistical quality control of these standards shall basically have a large number of test equipment for each product, ensure sufficient test time and continuous sampling of product samples. In the end, companies that produce and sell electric appliances are striving to control mass production at a great cost, but this is not acceptable. This study presents basic characteristics of the energy efficiency of electrical products and proposes and conducts a case study on statistical production control methods for performance variation across products under the standards about domestic and international regulations.

선형개조 다랑어 선망선의 조업성능 (Fishing performance of hull form renovated tuna purse seiner)

  • 홍진근;강일권;정성재
    • 수산해양기술연구
    • /
    • 제51권3호
    • /
    • pp.321-332
    • /
    • 2015
  • In an attempt to find the improvement of the fishing efficiency according to the hull form remodeling for the 3 tuna purse seiner, the Catch-Per-Unit-Effort (CPUE) for that undertaken before (2008) and after (2010) was analyzed. In addition, the CPUE of 6 similar ships operated same period and same fishing ground. As result, it came to verify that the three modified ships had a significant value on the CPUE. An another index for the improvement of fishing efficiency is the rate of reduction of fuel oil consumption for the modified ships. Fuel oil consumption per day in service speed as comparing with the original ships were reduced 2.1%, 4.0% and 5.1% on the modified ship A, B, and C respectively. And each ship's service speed was increased 1.0 kt, 0.6 kt, and 0.4 kt according to the modified ship A, B, and C in due order. In the conclusion, the remodeling job with newly equipped bulbous bow, lengthened slipway and enlarged rudder area were improved fairly much on fuel oil efficiency, the ship's speed, and in the end, that led to the improving fishing efficiency. Hence, the remodeling of tuna purse seiner come to improve not only the fishing performance, but contribute to the reduction of operating cost by saving energy for the fisheries industry.

공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 - (Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul-)

  • 박소윤;이윤재;이현수
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

고효율전동기 보급정책의 경제성 분석 (Analysis on the Promotion Programs for High-Efficiency Induction Motors)

  • 김발호;정구형;전영환
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.118-123
    • /
    • 2003
  • 유도전동기는 단일기기로서 가장 많은 전력을 사용하고 있는 부하로서, 우리나라의 전력사용량 중 약 40%를 소비하고 있다. 따라서 유도전동기의 고효율화는 시급한 국가적 과제이다. 본 논문에서는 고효율유도 전동기의 보급에 있어서 가장 큰 장애요인인 초기구입비 상승에 따른 구매기피를 극복하기 위한 여러 방안 중 가장 효과적인 방법으로 알려진 고효율유도전동기 리베이트제도의 시행방안을 수립하고 이의 경제성을 평가한다. 그리고 리베이트제도로 전환된 고효율유도전동기의 시장을 유지하기 위한 강제규정으로서 최저효율제와의 연계방안을 수립한다.